Proton Calorimetry/Experimental Runs: Difference between revisions
Jump to navigation
Jump to search
SimonJolly (talk | contribs) No edit summary |
SimonJolly (talk | contribs) No edit summary |
||
Line 5: | Line 5: | ||
; [[/2018/Mar8-9|8th-9th March 2018]] | ; [[/2018/Mar8-9|8th-9th March 2018]] | ||
: First experimental measurements of the plastic scintillator range calorimeter. | : First experimental measurements of the plastic scintillator range calorimeter. | ||
: Measurements at 28 and 36 MeV using ISDI sensor and Nikon DSLR. | |||
; [[/2018/Feb21|21st February 2018]] | ; [[/2018/Feb21|21st February 2018]] |
Revision as of 11:17, 12 March 2018
Information is available for the following experimental runs:
2018
- 8th-9th March 2018
- First experimental measurements of the plastic scintillator range calorimeter.
- Measurements at 28 and 36 MeV using ISDI sensor and Nikon DSLR.
- 21st February 2018
- Experimental measurements at Birmingham using fast treatment plan verification test setup.
- Measurements of 2 and 3 mm scintillator sheets
- Thickness measurements of 2 mm and 3 mm thick scintillator sheets from Nuvia.
- Plan of Action for January–March 2018
- Plan of action for range calorimeter assembly and experimental tests from January to March 2018.
2017
- 7th September 2017
- Tests of Nuvia scintillator stacks with PRaVDA CMOS pixel sensors (PRIAPUS) at the Birmingham Cyclotron with a 28 MeV beam.
- 10th August 2017
- Tests of Nuvia scintillator stacks with PRaVDA CMOS pixel sensors (PRIAPUS).
- 1st-3rd March 2017
- Measurements at MedAustron with longer scintillator and 252MeV beam.
- Give short explanation of the purpose and results.
2016
- 24th-25th November 2016
- Give short explanation of the purpose and results.
- 2nd-3rd August 2016
- Energy-to-range calibration measurements with a calibration wheel used by physicists at Clatterbridge with detector module comprising a 2" PMT and new PS-based scintillator.
- Data cross-checking measurements taken with the wheel to that taken with PMMA blocks of equivalent thickness at the same location, and further upstream at the modulator box.
- Measured total dose delivered to the new PS-based scintillator for radiation damage and hardness considerations.
- Recorded waveform data with new LeCroy HDO6104 oscilloscope.
- Made neutron measurements with the large 8" PMT hexagonal block module.
2015
- 21st-22nd December 2015
- Give short explanation of the purpose and results.
- 8th-9th July 2015
- Give short explanation of the purpose and results.
2014
- 8th-9th December 2014
- Give short explanation of the purpose and results.
2013
- 9th-10th December 2013
- Give short explanation of the purpose and results.