Proton Calorimetry/QuARC Data Files

From PBTWiki
Jump to navigation Jump to search

Details of the formats used in the various data files produced when taking data with the QuARC.

Calibrated Data Files

The calibrated data files contain a header, each of the individual PD measurements after calibration and background subtraction and the average value of these measurements + its error.

File Header Structure

UCL QuARC Number of header lines:

Facility:

Room:

Date:

Time:

Energy:

Intensity:

Folder:

Original Data File:

Background File:

Back ST File:

Front ST File:

Data type: Calibrated


Main Data

PD position

Sheet centre x positions


DATA

Every line is an individual PD measurement calibrated and with background subtracted.

Usually 30k lines.


AVERAGE

Average of all the individual PD measurements.

Error of the average measurement.

Fitted Data Files

The fitted data file averages the individual measurements at a specified frequency (the default is 25 Hz) and performs a fitting procedure, that varies if we have pristine BP or SOBP:

- Pristine BP: each of the averaged measurements is individually fitted to Bortfeld + Kelleter and then the energy and range values are extracted. The final measurement includes the average of the PD with its correspondent fittings and values.

- SOBP: the averaged measurements are NOT fitted, their curves show 0s. The final averaged value is fitted.

File Header Structure

UCL QuARC

HEADERLINES: 13

Facility:

Room:

Date:

Time:

Energy:

Intensity:

Folder:

Original data file:

Data type: Fitted

Fit rate:

Main Data

MEASUREMENT k (or average for final value)

Sheet centre x positions

Photodiode charge

Photodiode error

Fitted X-values

Kelleter curve

Bortfeld curve

Fitted energy

Fitted range

Raw Data Files