Proton Calorimetry/Experimental Runs/2025/Trento 2025-03: Difference between revisions
SimonJolly (talk | contribs) |
SimonJolly (talk | contribs) |
||
Line 215: | Line 215: | ||
|33 || 1, 2, 3 || 179 || 215 || 80nA || - || - || 8.7 || 100 || 220 || 3 || 0 || CONV full energy, high current || 80nA ion source current, out of sequence, max 45pC per channel || || | |33 || 1, 2, 3 || 179 || 215 || 80nA || - || - || 8.7 || 100 || 220 || 3 || 0 || CONV full energy, high current || 80nA ion source current, out of sequence, max 45pC per channel || || | ||
|- | |- | ||
|34 || 1, 2, 3 || 179 || 215 || | |34 || 1, 2, 3 || 179 || 215 || 40nA || - || - || 8.7 || 50 || 220 || 3 || 0 || CONV full energy, high current || 40nA ion source current || || | ||
|- | |||
|35 || 1, 2, 3 || 179 || 215 || 40nA || - || - || 8.7 || 50 || 220 || 3 || 0 || CONV full energy, high current || 20nA ion source current || || | |||
|- | |||
|36 || 1, 2, 3 || 148 || 155 || 300nA || - || - || 10.6 || 350 || 220 || 3 || 0 || CONV full energy, high current || 300nA ion source current || || | |||
|- | |||
|37 || 1, 2, 3 || 112 || 95 || 300nA || - || - || 13.3 || 350 || 220 || 3 || 0 || CONV full energy, high current || 300nA ion source current || || | |||
|- | |||
|38 || 1, 2, 3 || 70 || 41 || 300nA || - || - || 16.2 || 350 || 220 || 3 || 0 || CONV full energy, high current || 300nA ion source current || || | |||
|- | |||
|39 || 1, 2, 3 || Background || || 0 || 0 || 0 || N/A || 350 || 220 || 3 || 0 || Background || Lid closed || || | |||
|- | |||
|40 || 1, 2, 3 || Background || || 0 || 0 || 0 || N/A || 12.5 || 220 || 3 || 0 || Background || Lid closed || || | |||
|- | |- | ||
|} | |} | ||
== Measurements 30/09/2025 == | == Measurements 30/09/2025 == |
Revision as of 16:16, 30 September 2025
Beam Time Request Forms
https://www.hep.ucl.ac.uk/pbt/wikiData/BeamRequests/Trento_09_2025/
Experiment Equipment
Item | Notes |
---|---|
Network Hub | Set in control room to take output from experimental room ethernet connection. Control laptops connected via 5GHz WiFi. |
Control Laptop x2 | 1 for remote control of FPGA, 1 for notes/web GUI. |
Ethernet Cable x 2 | To connect DAQ laptop to network in the experimental room, control laptop to network in control room. |
Portable Enclosure | |
Scintillator stacks | 4 Modules (to cover the full clinical range, from 60 to 250 MeV) |
Scintillating fibers module | 1 2D Module |
DAQ laptop x1 | Control photodiode acquisition. |
Nexys Video FPGA development board. | For interfacing between DDC232 and PC. |
Schematic
Fiber Module Experiment Equipment
Item | Notes |
---|---|
2D Fiber Arrays | 2 Modules of vertical and horizontal fibers |
Read-out electronics | 2 Hamamatsu S13885-128 photodiode array each coupled to a Hamamatsu C9118-02 driver circuit |
ZYBO Z7-10 Diligent FPGA development board. | To provide clocks to C9118. |
NI USB-6366 Multifunction I/O device. | For interfacing between C9118 and PC. |
DAQ laptop x1 | Control photodiode acquisition. |
Experiment Plan
For each beam delivery, our acquisition time is 5 seconds. This gives us an optimal number of events. For FLASH beam time restrictions, we could consider reducing the acquisition time, if necessary.
- Set up mains cabling and networking in treatment and control rooms.
- no beam
- Install Peli case on treatment couch.
- no beam
- Background
- no beam
- Calibration shoot-through measurements of 4 stack modules: either rotating case or modules for back shoot-through:
- 8 beam deliveries 245 MeV conventional current (2 beam deliveries (back and forth) per each module)
- additional 2 or 3 beam deliveries 245 MeV at conventional current might be needed to find the minimum DDC232 FSR that does not saturate the signal.
- 8 beam deliveries 245 MeV FLASH current (2 beam deliveries (back and forth) per each module)
- additional 2 or 3 beam deliveries 245 MeV at FLASH current might be needed to find the minimum DDC232 FSR that does not saturate the signal.
- Pristine Bragg peak measurements at clinical current for full clinical range:
- 19 beam deliveries from 245 MeV and 240 to 70 MeV in 10 MeV steps.
- Pristine Bragg peak measurements at FLASH current for full clinical range:
- 19 beam deliveries from 245 MeV and from 240 to 70 MeV in 10 MeV steps at FLASH current.
- if there is FLASH beam time limitation we can take less energies points. Moreover, we could reduced the acquisition time for each FLASH beam delivery.
- 19 beam deliveries from 245 MeV and from 240 to 70 MeV in 10 MeV steps at FLASH current.
- Spot scanning:
- pristine Bragg Peak measurements at fixed energy (i.e. 150 MeV and 245 MeV) and clinical current shifting the beam up, down, left and right wrt isocenter by 3mm
- 4 beam deliveries per energy
- pristine Bragg Peak measurements at fixed energy (i.e. 150 MeV and 245 MeV) and clinical current shifting the beam up, down, left and right wrt isocenter by 3mm
Setup
- Peli case set up on FLASH station.
- Network connected through TIFPA experimental room patch panel:
- Inside experimental room:
- Long cable from patch panel (1) to DLink switch.
- Long cable from switch to QuARC.
- Short cable from switch to profile monitor DAQ laptop.
- Inside control room:
- Long cable from patch panel (5) to GL.iNet Slate router.
- Short cables to laptops.
- Inside experimental room:
- Case aligned to room lasers:
- Blocks used for levelling.
- Set up on height adjustable platform.
- Aligned to front cover plate.
Measurements 29/09/2025
- Approximately 100 minutes running 29/09/2025 (20:50–22:30).
- Peli case set up without movable stage: 1cm block under front, ~3mm under rear to level case.
- Isocentre at upstream face of first stack (level with inner edge of wheel mounts).
- Alignment checked with in room lasers after each adjustment.
- Beam optics are different between CONV mode and FLASH mode:
- Other than FLASH shoot through measurement with stack 1, running restricted to CONV mode.
- Current sufficient at maximum ion source current to almost saturate QuARC).
- SciFi monitor not installed.
Calibration conventional and FLASH
Run number | Modules | Beam Energy (MeV) | Estimated Range (mm) | Ion Source Current (nA) | Delivered protons | Irradiation time | Spot size (mm, FWHM) | DDC232 FSR (pC) | DDC232 Integration Time (us) | Acquisition Time (s) | Degrader WET (mm) | Beam setup | Comments | Photodiode QB Fit | Replay Fit |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | 1, 2, 3 | Background | 0 | 0 | 0 | N/A | 12.5 | 220 | 3 | 0 | Background | Lid open | |||
2 | 1 | Background | N/A | 0 | 0 | 0 | N/A | 12.5 | 170 | 3 | 0 | Background | Lid open | ||
3 | 1 | Background | N/A | 0 | 0 | 0 | N/A | 12.5 | 170 | 3 | 0 | Background | Lid open, added network switch to DAQ chain | ||
4 | 1 | Background | N/A | 0 | 0 | 0 | N/A | 12.5 | 170 | 3 | 0 | Background | Lid closed, BG with lid open ~0.10pC per PD, lid closed ~0.014pC | ||
5 | 1 | Background | N/A | 0 | 0 | 0 | N/A | 12.5 | 170 | 3 | 0 | Background | Lid open, Added long network cable between switch and wall patch panel | ||
6 | 1 | Background | N/A | 0 | 0 | 0 | N/A | 12.5 | 170 | 3 | 0 | Background | Lid closed, Peli case moved to FLASH beamline station and aligned with lasers @15.13 | ||
7 | 1 | Background | N/A | 0 | 0 | 0 | N/A | 12.5 | 170 | 5 | 50 | Background | Peli case aligned, cover plates removed, 50mm WET installed | ||
8 | 1 | 228 | 325 | - | - | - | 6.8 | 12.5 | 170 | 5 | 50 | FLASH, low current, shoot through front | Only 50% of measurements acquired, saturating; aiming for 1nA at detector | ||
9 | 1 | 228 | 325 | - | - | - | 6.8 | 12.5 | 170 | 5 | 50 | FLASH, low current, shoot through front | 4 sheets saturating; aiming for 0.5nA at detector | ||
10 | 1 | 228 | 325 | - | - | - | 6.8 | 12.5 | 170 | 5 | 50 | FLASH, low current, shoot through front | Sheets saturating; aiming for 0.5nA at detector; switching to CONV optics | ||
11 | 1 | 228 | 325 | 10 | 4E9 | - | 6.8 | 12.5 | 170 | 5 | 50 | CONV, high current, shoot through front | Switch to CONV mode, good FSR | ||
12 | 1 | 228 | 325 | 20 | - | - | 6.8 | 350 | 170 | 5 | 50 | CONV, high current, shoot through front | ~20nA isocentre, ~120pC per sheet maximum | ||
13 | 1 | 228 | 325 | - | 3E12 | - | 6.8 | 350 | 170 | 3 | 50 | CONV, high current, shoot through front | ~50nA isocentre, ~270pC per sheet maximum, Raspberry Pi frozen, restarted: only ~58% measurements recorded | ||
14 | 1 | Background | N/A | 0 | 0 | 0 | N/A | 12.5 | 170 | 3 | 50 | Background | Lid closed, stack rotated | ||
15 | 1 | 228 | 325 | 10 | 4E9(?) | - | 6.8 | 12.5 | 170 | 5 | 50 | CONV, shoot through back | ~1nA isocentre(?) | ||
16 | 2 | Background | N/A | 0 | 0 | 0 | N/A | 12.5 | 170 | 5 | 50 | Background | Lid closed, module 2 installed | ||
17 | 2 | 228 | 325 | 1 | - | - | 6.8 | 12.5 | 170 | 5 | 50 | Shoot through front | |||
18 | 2 | 228 | 325 | 1 | - | - | 6.8 | 12.5 | 170 | 5 | 50 | Shoot through back | Rotated and reinstalled stack | ||
19 | 3 | Background | N/A | 0 | 0 | 0 | N/A | 12.5 | 170 | 5 | 50 | Background | Lid closed, module 3 installed | ||
20 | 3 | 228 | 325 | 1 | - | - | 6.8 | 12.5 | 170 | 5 | 50 | Shoot through front | |||
21 | 3 | 228 | 325 | 1 | - | - | 6.8 | 12.5 | 170 | 5 | 50 | Shoot through back | Rotated and reinstalled stack |
Bragg Peak Measurements
Run number | Modules | Beam Energy (MeV) | Estimated Range (mm) | Ion Source Current (nA) | Delivered protons | Irradiation time | Spot size (mm, FWHM) | DDC232 FSR (pC) | DDC232 Integration Time (us) | Acquisition Time (s) | Degrader WET (mm) | Beam setup | Comments | Photodiode QB Fit | Replay Fit | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
22 | 1, 2, 3 | Background | 0 | 0 | 0 | N/A | 12.5 | 220 | 5 | 0 | Background | Lid open, 3 modules installed | |||||||||||||||||||
23 | 1, 2, 3 | Background | 0 | 0 | 0 | N/A | 12.5 | 220 | 5 | 0 | Background | Lid closed, 3 modules installed | |||||||||||||||||||
24 | 1, 2, 3 | 179 | 215 | 1 | 1.3E11 | 20 | 8.7 | 12.5 | 220 | 5 | 0 | CONV full energy | 4 photodiodes saturating: drop next current in half, 1.3E11 in 20s | 25 | 1, 2, 3 | 179 | 215 | 15nA | - | - | 8.7 | 12.5 | 220 | 5 | 0 | CONV full energy | 15nA ion source current, ~1nA isocentre | ||||
26 | 1, 2, 3 | 179 | 215 | 300nA | - | - | 8.7 | 350 | 220 | 3 | 0 | CONV full energy, high current | 300nA ion source current, ~10nA isocentre | ||||||||||||||||||
27 | 1, 2, 3 | 179 | 215 | 250nA | - | - | 8.7 | 350 | 220 | 3 | 0 | CONV full energy, high current | 250nA ion source current, ~8.3nA isocentre | ||||||||||||||||||
28 | 1, 2, 3 | 179 | 215 | 200nA | - | - | 8.7 | 350 | 220 | 3 | 0 | CONV full energy, high current | 200nA ion source current, ~6.7nA isocentre | ||||||||||||||||||
29 | 1, 2, 3 | 179 | 215 | 150nA | - | - | 8.7 | 350 | 220 | 3 | 0 | CONV full energy, high current | 150nA ion source current, ~5nA isocentre | ||||||||||||||||||
30 | 1, 2, 3 | 179 | 215 | 100nA | - | - | 8.7 | 350 | 220 | 3 | 0 | CONV full energy, high current | 100nA ion source current, ~3.3nA isocentre | ||||||||||||||||||
31 | 1, 2, 3 | Background | 0 | 0 | 0 | N/A | 350 | 220 | 3 | 0 | Background | ||||||||||||||||||||
32 | 1, 2, 3 | 179 | 215 | 60nA | - | - | 8.7 | 50 | 220 | 3 | 0 | CONV full energy, high current | 60nA ion source current, had to retake | ||||||||||||||||||
33 | 1, 2, 3 | 179 | 215 | 80nA | - | - | 8.7 | 100 | 220 | 3 | 0 | CONV full energy, high current | 80nA ion source current, out of sequence, max 45pC per channel | ||||||||||||||||||
34 | 1, 2, 3 | 179 | 215 | 40nA | - | - | 8.7 | 50 | 220 | 3 | 0 | CONV full energy, high current | 40nA ion source current | ||||||||||||||||||
35 | 1, 2, 3 | 179 | 215 | 40nA | - | - | 8.7 | 50 | 220 | 3 | 0 | CONV full energy, high current | 20nA ion source current | ||||||||||||||||||
36 | 1, 2, 3 | 148 | 155 | 300nA | - | - | 10.6 | 350 | 220 | 3 | 0 | CONV full energy, high current | 300nA ion source current | ||||||||||||||||||
37 | 1, 2, 3 | 112 | 95 | 300nA | - | - | 13.3 | 350 | 220 | 3 | 0 | CONV full energy, high current | 300nA ion source current | ||||||||||||||||||
38 | 1, 2, 3 | 70 | 41 | 300nA | - | - | 16.2 | 350 | 220 | 3 | 0 | CONV full energy, high current | 300nA ion source current | ||||||||||||||||||
39 | 1, 2, 3 | Background | 0 | 0 | 0 | N/A | 350 | 220 | 3 | 0 | Background | Lid closed | |||||||||||||||||||
40 | 1, 2, 3 | Background | 0 | 0 | 0 | N/A | 12.5 | 220 | 3 | 0 | Background | Lid closed |
Measurements 30/09/2025
- Approximately 100 minutes running 29/09/2025 (20:50–22:30).
- Peli case set up without movable stage: 1cm block under front, ~3mm under rear to level case.
- Isocentre at upstream face of first stack (level with inner edge of wheel mounts).
- Alignment checked with in room lasers after each adjustment.
- Beam optics are different between CONV mode and FLASH mode:
- Other than FLASH shoot through measurement with stack 1, running restricted to CONV mode.
- Current sufficient at maximum ion source current to almost saturate QuARC).
- SciFi monitor not installed.
Spot scanning Measurements
Run number | Detector | Beam Energy (MeV) | Estimated Range (mm) | Current (nominal) (nA) | Spot size (mm, FWHM) | DDC232 FSR (pC) | DDC232 Integration Time (us) | Degrader WET (mm) | Comments | Photodiode QB Fit | Replay Fit |
---|---|---|---|---|---|---|---|---|---|---|---|
n | Full Stack | 245 MeV | - | - | N/A | 12.5 | 170 | top | N/A | ||
n | Full Stack | 245 MeV | - | - | N/A | 12.5 | 170 | bottom | N/A | ||
n | Full Stack | 245 MeV | - | - | N/A | 12.5 | 170 | left | N/A | ||
n | Full Stack | 245 MeV | - | - | N/A | 12.5 | 170 | right | N/A | ||
n | Full Stack | 150 MeV | - | - | N/A | 12.5 | 170 | top | N/A | ||
n | Full Stack | 150 MeV | - | - | N/A | 12.5 | 170 | bottom | N/A | ||
n | Full Stack | 150 MeV | - | - | N/A | 12.5 | 170 | left | N/A | ||
n | Full Stack | 150 MeV | - | - | N/A | 12.5 | 170 | right | N/A |