Proton Calorimetry/Experimental Runs/2015/Jul8-9: Difference between revisions
(Info dump: Handwritten notes from 08-09/07/2015 entered as tables with minimal formatting. Formatting and corrections to follow.) |
(Corrected errors in tables, added section headings and table of contents) |
||
Line 3: | Line 3: | ||
'''PAGE UNDER CONSTRUCTION''' | '''PAGE UNDER CONSTRUCTION''' | ||
=Day 1 (July 8th)= | |||
====Notes==== | |||
*Current at -800 V: 129.6 μA (beam off) | |||
*Background rate (-800 V on PMT, beam off, no collimator): ~5 Hz - 4 Hz | |||
**Threshold: -14 mV (for 10 segments) | |||
**Rise time: 8 - 14 ns (<14 ns) | |||
*Having the corridor lights on does NOT create enough light to trip PMT and is acceptable | |||
*For treatment, 8 mm - 20 mm collimator used | |||
===Negative Base Tests=== | |||
{|class="wikitable" | {|class="wikitable" | ||
Line 16: | Line 28: | ||
*0.6 cc/minute | *0.6 cc/minute | ||
*0 arc current | *0 arc current | ||
| | |||
|- | |- | ||
| || | Rate: 500 kHz || || | | || || | Rate: 500 kHz || || | ||
*0.6 cc/current | *0.6 cc/current | ||
*Tiny bit of arc | *Tiny bit of arc | ||
Line 183: | Line 195: | ||
| Voltage changed on Ds: 47.4% || 025 (list), 027 (eh) (4,000,000 events) | | Voltage changed on Ds: 47.4% || 025 (list), 027 (eh) (4,000,000 events) | ||
|- | |- | ||
| -800 || ST, list | | -800 || ST, list || | ||
*Rate: 625 kHz | *Rate: 625 kHz | ||
*I: 157 μA | *I: 157 μA | ||
Line 258: | Line 270: | ||
| || 051 (4,000,000 events) | | || 051 (4,000,000 events) | ||
|- | |- | ||
| -800 || ST, list || | | -800 || ST, list || || | ||
*Short gate: 80 ns | *Short gate: 80 ns | ||
*Long gate: 100 ns | *Long gate: 100 ns | ||
Line 290: | Line 302: | ||
|} | |} | ||
Notes | =Day 2 (July 9th)= | ||
*Current | |||
* | ====Notes==== | ||
* | |||
* | *From the morning of 9th July 2015 measurements taken without the black cloth covering the face of the scintillator. | ||
*Dark rates have increased to ~6.5 Hz (for a -30 mV threshold) | |||
*Current for dark rate: 129.66 μA | |||
*Distance between beam and EJ-Block scintillator: ~40 mm | |||
*No dark rate, background pickup up with beam off due to such a small scintillator size. | |||
*At 1450 V, I: 324 μA, but still no visible signal. Wrong PMT connected to signal. | |||
With correct PMT: | |||
*At 800 V dark current + background rate: ~40 Hz at -30 mV threshold, I: 178.6 μA | |||
*At 1000 V, dark current + background rates: 600 Hz at -30 mV threshold | |||
===Negative Base Tests=== | |||
{|class="wikitable" | {|class="wikitable" | ||
Line 323: | Line 343: | ||
*Short gate: 50 ns | *Short gate: 50 ns | ||
*Long gate: 100 ns | *Long gate: 100 ns | ||
| Unable to take run, too much instability | | || Unable to take run, too much instability | ||
|- | |||
| -800 || ST, list || | | -800 || ST, list || | ||
*Rate: 60 kHz | *Rate: 60 kHz | ||
Line 405: | Line 426: | ||
*Short gate: 50 ns | *Short gate: 50 ns | ||
*Long gate: 100 ns | *Long gate: 100 ns | ||
| 092 (2,000,000 events) | | || 092 (2,000,000 events) | ||
|- | |- | ||
| -800 || ST, waves || || | | -800 || ST, waves || || | ||
Line 493: | Line 514: | ||
3" PMT Tests | ===3" PMT Tests=== | ||
{|class="wikitable" | {|class="wikitable" | ||
Line 581: | Line 600: | ||
| No PMMA || 125 (700,000 events) | | No PMMA || 125 (700,000 events) | ||
|} | |} | ||
Latest revision as of 14:17, 27 July 2017
Include all details of experimental runs from Anastasia's PDFs.
PAGE UNDER CONSTRUCTION
Day 1 (July 8th)
Notes
- Current at -800 V: 129.6 μA (beam off)
- Background rate (-800 V on PMT, beam off, no collimator): ~5 Hz - 4 Hz
- Threshold: -14 mV (for 10 segments)
- Rise time: 8 - 14 ns (<14 ns)
- Having the corridor lights on does NOT create enough light to trip PMT and is acceptable
- For treatment, 8 mm - 20 mm collimator used
Negative Base Tests
High Voltage (V) | Trigger | Rate + Additional Information | Electronics Setup | Collimator Size + Additional Information | Run Number |
---|---|---|---|---|---|
-800 | ST | Rate: 50 Hz |
|
||
Rate: 500 kHz |
|
||||
Rate: ~200 kHz |
|
|
|||
-800 | ST | Rate: 50 Hz |
|
|
001 (60,000 events) |
-800 | ST, list |
|
|
5 mm | 002 (71,000 events) |
-800 | ST, list |
|
|
8 mm | 003 (350,000 events) |
40 MeV protons, therefore trigger on 14 mV is ~5%, usually require 10%. Trigger on 30 mV threshold from now on. | |||||
Lunch break | |||||
-800 | ST, list |
|
|
16 mm | 005 (350,000 events) |
-800 | ST, list | As above, repeated to study shoulder at ~2500 ADC | 006 (300,000 events) | ||
-800 | ST, list |
|
|
20 mm | 007 (400,000 events) |
-800 | ST, list |
|
|
24 mm | 008 (400,000 events) |
-800 | ST, list |
|
|
30 mm | 009 (400,000 events) |
-800 | ST, list |
|
|
|
010 (1,500,000 events) |
-800 | ST, list |
|
|
|
012 (1,500,000 events |
-800 | ST, list | All as above, but create larger statistics | 014 (3,000,000 events) | ||
-800 | ST, list |
|
|
|
016 (1,500,000 events) |
-800 | ST, list |
|
|
4 mm | 017 (3,000,000 events) |
-800 | ST, list |
|
|
3 mm | 018 (3,000,000 events) |
-800 | ST, list |
|
|
5 mm | 019 (5,000,000 events) |
-800 | ST, list |
|
|
6 mm | 020 (list), 021 (eh) (5,000,000 events) |
-800 | ST, list |
|
|
Voltage changed on Ds: 47.4% | 025 (list), 027 (eh) (4,000,000 events) |
-800 | ST, list |
|
|
Voltage on Ds changed back | 028 (3,000,000 events) |
-800 | ST, list | All as above, take second for crosscheck | 029 (2,300,000 events) | ||
-800 | ST, list |
|
|
6.99 mm | 030 (3,000,000 events) |
-800 | ST, list |
|
039 (4,000,000 events) | ||
-800 | ST, list |
|
|
|
044 (3,500,000 events) |
-800 | ST, list |
|
|
|
045 (4,000,000 events) |
-800 | ST, list |
|
|
|
046 (4,000,000 events) |
-800 | ST, list |
|
|
|
049 (4,000,000 events) |
-800 | ST, list |
|
051 (4,000,000 events) | ||
-800 | ST, list |
|
053 (4,000,000 events) | ||
-800 | ST, list |
|
054 (4,000,000 events) | ||
-800 | ST, list |
|
|
056 (4,000,000 events) | |
-800 | ST, list |
|
057 (4,000,000 events) | ||
-800 | ST, list |
|
|
0.5 cc/minute | 065 (4,000,000 events) |
Day 2 (July 9th)
Notes
- From the morning of 9th July 2015 measurements taken without the black cloth covering the face of the scintillator.
- Dark rates have increased to ~6.5 Hz (for a -30 mV threshold)
- Current for dark rate: 129.66 μA
- Distance between beam and EJ-Block scintillator: ~40 mm
- No dark rate, background pickup up with beam off due to such a small scintillator size.
- At 1450 V, I: 324 μA, but still no visible signal. Wrong PMT connected to signal.
With correct PMT:
- At 800 V dark current + background rate: ~40 Hz at -30 mV threshold, I: 178.6 μA
- At 1000 V, dark current + background rates: 600 Hz at -30 mV threshold
Negative Base Tests
High Voltage (V) | Trigger | Rate + Additional Information | Electronics Setup | Collimator Size + Additional Information | Run Number |
---|---|---|---|---|---|
-800 | ST, list |
|
|
|
068 (2,000,000 events) |
-800 | ST, list |
|
Unable to take run, too much instability | ||
-800 | ST, list |
|
|
No run, unstable | |
-800 | ST, list | Rate: 100 kHz, unstable |
|
No run, unstable | |
-800 | ST, list |
|
|
|
075 (250,000 events) |
-800 | ST, list |
|
076 (250,000 events) | ||
-800 | ST, list |
|
077 (230,000 events) | ||
-800 | ST, list |
|
078 (230,000 events) | ||
-800 | ST, waves |
|
079 (Waveforms) | ||
-800 | ST, list |
|
|
|
081 (2,000,000 events) |
-800 | ST, list |
|
085 (2,000,000 events) | ||
-800 | ST, list |
|
087 (2,000,000 events) | ||
-800 | ST, list | Note: Run shifts towards the end |
|
089 (2,000,000 events) | |
-800 | ST, list | Note: Repeat of above run, looks cleaner |
|
092 (2,000,000 events) | |
-800 | ST, waves |
|
093 (Waveforms) | ||
-800 | ST, list |
|
|
|
095 (2,000,000 events) |
-800 | ST, list |
|
096 (2,000,000 events) | ||
-800 | ST, list |
|
097 (2,000,000 events) | ||
-800 | ST, list |
|
098 (2,000,000 events) | ||
-800 | ST, list |
|
|
|
099 (2,000,000 events) |
-800 | ST, list |
|
100 (2,000,000 events) | ||
-800 | ST, list |
|
101 (2,000,000 events) | ||
-800 | ST, list |
|
102 (2,000,000 events) | ||
-800 | ST, list |
|
|
3 mm | 105 (7,500,000 events) |
-800 | ST, list |
|
106 (ls), 107 (eh) (7,000,000 events) | ||
Beam tripped out | |||||
-800 | ST, list |
|
108 (9,000,000 events) | ||
-800 | ST, list |
|
109 (ls), 110 (eh) (6,500,000 events) |
3" PMT Tests
High Voltage (V) | Trigger | Rate + Additional Information | Electronics Setup | Collimator Size + Additional Information | Run Number |
---|---|---|---|---|---|
800 | ST, list |
|
Signal is off the ADC scale! Reduce the voltage! |
|
|
700 | ST, list |
|
|
113 (165,000 events) | |
700 | ST, list |
|
|
20 mm | 116 (460,000 events) |
700 | ST, list |
|
|
5.07 mm of PMMA (1 plate) | 118 (715,000 events) |
700 | ST, list |
|
9.8 mm of PMMA (1 plate) | 119 (370,000 events) | |
700 | ST, list | Repeat above measurement after beam reset |
|
120 (800,000 events) | |
700 | ST, list |
|
14.12 mm of PMMA (1 plate) | 121 (900,000 events) | |
700 | ST, list |
|
17.94 mm of PMMA (9.04 mm + 10.9 mm, 2 plates) | 122 (950,000 events) | |
700 | ST, list |
|
19.94 mm of PMMA (9.04 mm + 10.9 mm, 2 plates) | 123 (805,000 events) | |
700 | ST, list |
|
21.70 mm of PMMA (9.04 mm + 12.66 mm, 2 plates) | 124 (550,000 events) | |
700 | ST, list |
|
|
No PMMA | 125 (700,000 events) |