Proton Calorimetry/QuARC Data Files: Difference between revisions
SimonJolly (talk | contribs) (Created page with "Details of the formats used in the various data files produced when taking data with the QuARC. == Fitted Data Files == === File Header Structure === === Main Data === == Cal...") |
|||
(5 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
Details of the formats used in the various data files produced when taking data with the QuARC. | Details of the formats used in the various data files produced when taking data with the QuARC. | ||
== Calibrated Data Files == | |||
The calibrated data files contain a header, each of the individual PD measurements after calibration and background subtraction and the average value of these measurements + its error. | |||
=== File Header Structure === | |||
UCL QuARC | |||
Number of header lines: | |||
Facility: | |||
Room: | |||
Date: | |||
Time: | |||
Energy: | |||
Intensity: | |||
Folder: | |||
Original Data File: | |||
Background File: | |||
Back ST File: | |||
Front ST File: | |||
Data type: Calibrated | |||
=== Main Data === | |||
PD position | |||
Sheet centre x positions | |||
DATA | |||
Every line is an individual PD measurement calibrated and with background subtracted. | |||
Usually 30k lines. | |||
AVERAGE | |||
Average of all the individual PD measurements. | |||
Error of the average measurement. | |||
== Fitted Data Files == | == Fitted Data Files == | ||
The fitted data file averages the individual measurements at a specified frequency (the default is 25 Hz) and performs a fitting procedure, that varies if we have pristine BP or SOBP: | |||
- Pristine BP: each of the averaged measurements is individually fitted to Bortfeld + Kelleter and then the energy and range values are extracted. The final measurement includes the average of the PD with its correspondent fittings and values. | |||
- SOBP: the averaged measurements are NOT fitted, their curves show 0s. The final averaged value is fitted. | |||
=== File Header Structure === | === File Header Structure === | ||
UCL QuARC | |||
HEADERLINES: 13 | |||
Facility: | |||
Room: | |||
Date: | |||
Time: | |||
Energy: | |||
Intensity: | |||
Folder: | |||
Original data file: | |||
Data type: Fitted | |||
Fit rate: | |||
=== Main Data === | === Main Data === | ||
MEASUREMENT k (or average for final value) | |||
Sheet centre x positions | |||
Photodiode charge | |||
Photodiode error | |||
Fitted X-values | |||
Kelleter curve | |||
Bortfeld curve | |||
Fitted energy | |||
Fitted range | |||
== Raw Data Files == | == Raw Data Files == |
Latest revision as of 13:57, 30 November 2023
Details of the formats used in the various data files produced when taking data with the QuARC.
Calibrated Data Files
The calibrated data files contain a header, each of the individual PD measurements after calibration and background subtraction and the average value of these measurements + its error.
File Header Structure
UCL QuARC Number of header lines:
Facility:
Room:
Date:
Time:
Energy:
Intensity:
Folder:
Original Data File:
Background File:
Back ST File:
Front ST File:
Data type: Calibrated
Main Data
PD position
Sheet centre x positions
DATA
Every line is an individual PD measurement calibrated and with background subtracted.
Usually 30k lines.
AVERAGE
Average of all the individual PD measurements.
Error of the average measurement.
Fitted Data Files
The fitted data file averages the individual measurements at a specified frequency (the default is 25 Hz) and performs a fitting procedure, that varies if we have pristine BP or SOBP:
- Pristine BP: each of the averaged measurements is individually fitted to Bortfeld + Kelleter and then the energy and range values are extracted. The final measurement includes the average of the PD with its correspondent fittings and values.
- SOBP: the averaged measurements are NOT fitted, their curves show 0s. The final averaged value is fitted.
File Header Structure
UCL QuARC
HEADERLINES: 13
Facility:
Room:
Date:
Time:
Energy:
Intensity:
Folder:
Original data file:
Data type: Fitted
Fit rate:
Main Data
MEASUREMENT k (or average for final value)
Sheet centre x positions
Photodiode charge
Photodiode error
Fitted X-values
Kelleter curve
Bortfeld curve
Fitted energy
Fitted range