This file contains little bits from other files ---------------------------------------------------------------- Register List ---------------------------------------------------------------- ID: Addr: Name: Size: Access: Special: Registers: ---------- 0 00h Data 24 bit rw 1 04h Feedback0 8 bit ro 2 08h Feedback1 8 bit ro 3 0Ch Feedback2 8 bit ro 4 10h Status 3 bit ro wr=reset 5 14h Trigger Counter 8 bit ro 6 18h Test Pulse Enable 15 bit rw 7 1Ch Serial Load Sent 15 bit ro wr=reset Commands: (activate with a read) -------------------------------- 8 20h Serial Program Mode Set 9 24h Start Serial Program Cycle 10 28h Test Trigger 11 2Ch Trigger (Normal) Mode Set 12 30h unused 13 34h unused 14 38h unused 15 3Ch Reset Board Programmable Delays: -------------------- 16 40h Delay Ch 0 wo 17 44h Delay Ch 1 wo 18 48hD Delay Ch 2 wo 19 4Ch Delay Ch 3 wo 20 50h Delay Ch 4 wo 21 54h Delay Ch 5 wo 22 58h Delay Ch 6 wo 23 5Ch Delay Ch 7 wo 24 60h Delay Ch 8 wo 25 64h Delay Ch 9 wo 26 68h Delay Ch 10 wo 27 6Ch Delay Ch 11 wo 28 70h Delay Ch 12 wo 29 74h Delay Ch 13 wo 30 78h Delay Ch 14 wo 31 7Ch Delay Ch 0-14 (all) wo Status Register: ---------------- bit 0 - Serial Download Busy 1 - Test Sent (1 = yes) 2 - Trigger Sent (1 = yes) 3 - Mode (Serial/nTrig) 4 - Clock On ------------------------------------------------------------------------------ PSU Cable Pins ------------------------------------------------------------------------------ Sig: DB15 pin +3.8V: 1, 2, 9 -1.2V: 4, 11, 12 -5V: 6 +3.8Vs: 10 -1.2Vs: 3 -5Vs: 14 VME+5: 13 VME0V: 5, 7 ------------------------------------------------------------------------------ Controller Front Panel Use ------------------------------------------------------------------------------ Remote status LED off = Controller Off LED green = Controller On LED red = ----> LED goes red during controller initialise, this results in a short flash (<.1s) after a pushbutton reset, and a longer flash (.5s) after power-up. The LED also goes red (1s) during normal operation to show a serial receive timeout . ie I don't get a full 8 byte message quickly. Remote overide switch up = ----> Overides the controller and sets the Controller's relay ON. This does not affect the interlock with the VME crate. switch middle = Nothing (default) switch down = ----> Removes the controller overide (ie gives control of the relay back to the controller) Reset/test switch pressed = Controller stops switch released = Controller restarts Note: In both of these cases the PSU Module ON/OFF state is unaffected