MTC/LTC Setups
Z-MTC-1 SETTING - UP LIST
All diagram numbers refer to the latest -A- version of
CAD FILE TITLE WW1038, Issue A ( WIRE WRAP Z-MTC )
dated AUGUST 1991
Diag.No: Set:
======== ====
1) 12 Connect all clock links as follows :
------------------------------------
CLK11: DL4/11 to U118/3
CLK13: DL8/3 U118/8
CLK14: DL4/4 DL7/2
DL7/3 U118/4
( DL9 by-passed )
CLK21: DL6/11 U118/6
CLK23: DL8/1 U118/9
CLK24: DL8/12 U118/7
NCLK2.: DL6/10 U167/1
MTCSTR.:DL4/12 U118/2
( DL5 by-passed )
P1 to P2 ( PLL 48NSCK )
2) Set DIL SWITCH SW.1 as follows :
--------------------------------
16 SW.1A P/L CYCLE - OFF - ( Continuous )
10 SW.1B XTAL CLK - ON - ( Continuous )
12 SW.1C CLK SPEED - ON - ( 48 nsec )
10 SW.1D CLK SELECT - ON - ( ROC control )
This version: MP-UCL, 3 Aug. 1994
Previous versions : 21 Sep. 1993
22 Sep. 1992
Z-MTC-2 SETTING - UP LIST
All diagram numbers refer to the latest -A- version of
CAD FILE TITLE PC3027M Issue A ( Z MASTER TIMING
CONTROLLER ) dated 24.1.95
Diag.No: Set:
======== ====
1) 12 Wire-wrap CLOCK TIMING LINKs as follows :
-----------------------------------------
CLK11: P56 ( DL3/12 ) to P46 ( U68/3 )
CLK13: P77 ( DL7/3 ) P51 ( U68/8 )
CLK14: P58 ( DL3/11 ) P47 ( DL6/2 )
P99 ( DL6/2 ) P87 ( U68/4 )
( = DL6 by-passed )
CLK21: P69 ( DL5/11 ) P48 ( U68/6 )
CLK23: P75 ( DL7/1 ) P50 ( U68/9 )
CLK24: P78 ( DL7/12 ) P52 ( U68/7 )
NCLK2: P71 ( DL5/10 ) P49 ( U67/3 )
MTCSTR.:P56 ( DL3/12 ) P45 ( DL4/2 )
P88 ( DL4/2 ) P86 ( U68/2 )
( = DL4 by-passed )
2) 20 Wire-wrap CLOCK TIMING LINKs as follows :
-----------------------------------------
INCLK: P31 ( DL2/12 ) to P26 ( U44/4 )
INCLK2: P30 ( DL2/3 ) P25 ( U44/3 )
CLKIN: P1 ( U56/9 ) P4 ( U15/28)
P27 ( DL1/2 ) P32 ( DL2/4 )
P48NS: P14 ( DL1/5 ) P10 ( U30/2 )
N48NS: P13 ( DL1/4 ) P9 ( U43/1 )
3) 14 Connect MTCBUSY ENABLE LINK :
-----------------------------
P40 to P41
4) 18 Connect ROCPIPEFR ENABLE LINK :
-------------------------------
P43 to P44
5) 20 Connect 2ERRORON ENABLE LINK :
------------------------------
P7 to P8
6) Set DIL SWITCH SW.11 as follows :
---------------------------------
16 SW.11A P/L CYCLE - OFF - ( Continuous )
10 SW.11B XTAL CLK - ON - ( Continuous )
12 SW.11C CLK SPEED - ON - ( 48 nsec )
10 SW.11D SELECT CLK - ON - ( ROC selects )
This version: MP-UCL, 17 Mar. 1996
Previous versions : 2 June 1995
3 May 1995
2 May 1995
7 Nov. 1994
Z-LTCC-5 MULTIWIRE BOARDS SETTING-UP LIST
All diagram numbers refer to the latest -B- version of
CAD FILE TITLE PC2915M, Issue B ( MULTIWIRE Z-LTCC )
dated Sept. 1992
Diag.No: Set:
======== ====
1) 14 Connect all clock links as follows :
------------------------------------
CLK11: LK12/4 ( DL5/12 ) to P12 ( U129/3 )
CLK13: LK16/4 ( DL9/12 ) P19 ( U129/8 )
CLK14: LK12/10 ( DL5/9 )*#% P13 ( DL8/2 )
--------------------
LK15/1 ( DL8/2 ) P17 ( U130/1 )
LK17/7 ( DL10/9 )% P21 ( U68/9 )
P24 ( U132/4 )% P22 ( DL10/2 )
CLK21: LK14/6 ( DL7/11 ) P16 ( U129/6 )
CLK23: LK16/1 ( DL9/1 ) P20 ( U129/9 )
CLK24: LK16/4 ( DL9/12 ) P18 ( U129/7 )
NCLK2: LK14/5 ( DL7/4 )#% P15 ( U128/13)
MTCSTR.:LK12/2 ( DL5/13 ) P11 ( DL6/2 )
LK13/1 ( DL6/2 ) P14 ( U129/2 )
NOTES: * indicates the CLK14 link which should be adjusted
====== to correct any Z-CARD Data Transfer timing errors
# ON LTCC-5/1 ONLY, FOR RBOX-1 USE :
==================================
CLK14 set +13nsec ( = -35ns ) = LK12/3 ( DL5/3 )
NCLK2 set +10nsec = LK14/7 ( DL7/5 )
% ON LTCC-5/2 ONLY, FOR RBOX-2 & Z-CARD USE :
===========================================
CLK14 set +18nsec ( = -30ns ) = LK12/4 ( DL5/12)
NCLK2 set +10nsec = LK14/7 ( DL7/5 )
CLK14 set width +9nsec = LK17/11 ( DL10/13)
= P25 ( U132/16)
2) Connect DIL LINKS LK11 A,B,C,D as follows :
---------------------------------------------
18 LK11A P/L CYCLE - no - ( continuous )
12 LK11B XTAL CLK - no - ( ROC control )
14 LK11C CLK SPEED - YES - ( 48 nsec )
12 LK11D CLK SELECT - YES - ( ROC control )
3) 09 Set Vth potentiometers P1 - P4 to obtain the
required Vth voltage reading on
Test Points TP1 - TP4
( using digital multimeter )
TP1 : -5.0V
TP2 : -5.0V
TP3 : -5.0V
TP4 : -5.0V
This version : MP-UCL, 18 Aug. 1994
Previous versions : 3 Aug. 1994
23 Mar. 1994
20 Sep. 1993
Z-LTCC-6 & 7 MULTIWIRE BOARDS SETTING-UP LIST
All diagram numbers refer to the latest -C- version of
CAD FILE TITLE PC2915M, Issue C ( MULTIWIRE Z-LTCC )
dated Oct. 1993
Diag.No: Set:
======== ====
1) 14 Connect all clock links as follows :
------------------------------------
CLK11: LK12/4 ( DL5/12 ) to P12 ( U129/3 )
CLK13: LK16/4 ( DL9/12 ) P19 ( U129/8 )
CLK14: *LK12/10 ( DL5/9 )* P13 ( DL8/2 )
--------------------
LK15/1 ( DL8/2 ) P17 ( U130/1 )
LK17/5 ( DL10/6 ) P21 ( U68/5 )
P24 ( U132/4 ) P22 ( DL10/2 )
CLK21: LK14/6 ( DL7/11 ) P16 ( U129/6 )
CLK23: LK16/1 ( DL9/1 ) P20 ( U129/9 )
CLK24: LK16/4 ( DL9/12 ) P18 ( U129/7 )
NCLK2: LK14/5 ( DL7/4 ) P15 ( U128/13)
MTCSTR.:LK12/2 ( DL5/13 ) P11 ( DL6/2 )
LK13/1 ( DL6/2 ) P14 ( U129/2 )
NOTE: * indicates the CLK14 link which should be adjusted
===== to correct any Z-CARD Data Transfer timing errors
2) Connect DIL LINKS LK11 A,B,C,D as follows :
---------------------------------------------
18 LK11A P/L CYCLE - no - ( continuous )
12 LK11B XTAL CLK - no - ( ROC control )
14 LK11C CLK SPEED - YES - ( 48 nsec )
12 LK11D CLK SELECT - YES - ( ROC control )
3) 09 Set Vth potentiometers P1 - P4 to obtain the
required Vth voltage reading on
Test Points TP1 - TP4
( using digital multimeter )
TP1 : -5.0V
TP2 : -5.0V
TP3 : -5.0V
TP4 : -5.0V
This version : MP-UCL, 23 Mar. 1994
Previous versions : 20 Sep. 1993