Proton Calorimetry/Meetings/2017/08/16

From PBTWiki
Revision as of 14:20, 16 August 2017 by SimonJolly (talk | contribs) (Created page with "== Minutes for UCL Proton Calorimetry Meeting, 16th August 2017 (D107, Physics & Astronomy, UCL) == === Present === '''Simon Jolly''', '''Laurent Kelleter''', '''Jordan Silverm...")
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search

Minutes for UCL Proton Calorimetry Meeting, 16th August 2017 (D107, Physics & Astronomy, UCL)

Present

Simon Jolly, Laurent Kelleter, Jordan Silverman

LK:

  • Ran a few more simulations for build-up paper:
    • Bortfeld description fails between 200–300 MeV: at 500 MeV description is very poor (Bortfeld recommends only between 40–200 MeV).
    • At 500 MeV "entrance bump" is almost as large as the Bragg peak!
    • Electron build-up measured within the simulation by counting energy deposition attributed to electrons at each step.
    • Compare dose at depth to dose at 0.07 mm to define build-up (appropriate skin depth): approx. 2% of Bragg peak depth.
    • Hadronic build-up defined by secondary protons: several orders of magnitude larger than heavier hadrons.
    • Liquid Hydrogen simulations show much smaller entrance bump: secondary proton spectrum still retains Bragg peak (Oxygen no longer disrupting primary proton energy).
    • No secondary production of hadrons after Bragg peak in liquid Hydrogen: no neutron production so nothing gets past Bragg peak.
  • Testing PRaVDA PRIAPUS CMOS sensor:
    • Flashed single scintillator sheets with LED and imaged light with PRIAPUS.
    • Checked different scintillator thicknesses (3 and 10 mm) and different LED voltages.
    • Checked spacing between sensor and scintillator: need to keep scintillator as close to sensor as possible without touching it! Minimum distance tried was 2 mm.
    • Beam test at Birmingham Wednesday 23rd August.

JS: