User contributions for MatthieuHentz
A user with 276 edits. Account created on 12 April 2017.
9 July 2017
- 16:2316:23, 9 July 2017 diff hist −7 Clatterbridge →Dosimetry box
- 16:2316:23, 9 July 2017 diff hist −7 Clatterbridge →Dual scattering tube
- 14:3214:32, 9 July 2017 diff hist +6 Clatterbridge →Visualisation
- 14:3214:32, 9 July 2017 diff hist +7 Clatterbridge →Dosimetry box
- 14:3114:31, 9 July 2017 diff hist +7 Clatterbridge →Dual scattering tube
- 14:3114:31, 9 July 2017 diff hist +12 Clatterbridge →Beamline
8 July 2017
- 13:0413:04, 8 July 2017 diff hist +51 Clatterbridge →output1759.txt
- 12:5812:58, 8 July 2017 diff hist −129 Clatterbridge →ProtonFluxBeamline.txt
- 12:3612:36, 8 July 2017 diff hist +92 Clatterbridge →ProtonFluxBeamline.txt
- 12:2212:22, 8 July 2017 diff hist −16 Clatterbridge →Make the simulation
- 12:0512:05, 8 July 2017 diff hist +25 Clatterbridge →ProtonFluxBeamline.txt
7 July 2017
- 23:2823:28, 7 July 2017 diff hist −398 Clatterbridge →Output files
- 19:3819:38, 7 July 2017 diff hist +362 Clatterbridge No edit summary
- 18:5418:54, 7 July 2017 diff hist −39 Clatterbridge →Running a split simulation
- 18:5318:53, 7 July 2017 diff hist +2 Clatterbridge →Running a split simulation
- 18:5318:53, 7 July 2017 diff hist +145 Clatterbridge →Running simulations
- 18:2918:29, 7 July 2017 diff hist +62 Clatterbridge →Running a split simulation
- 18:1118:11, 7 July 2017 diff hist +660 Clatterbridge →Running large simulations
- 17:2717:27, 7 July 2017 diff hist +44 Clatterbridge →Running large simulations
- 17:1917:19, 7 July 2017 diff hist +521 Clatterbridge →Running large simulations
- 17:0717:07, 7 July 2017 diff hist +212 Clatterbridge →Running large simulations
- 17:0317:03, 7 July 2017 diff hist +435 Clatterbridge →Running large simulations
- 16:3816:38, 7 July 2017 diff hist +156 Clatterbridge →Running simulations
6 July 2017
- 22:1822:18, 6 July 2017 diff hist +34 Clatterbridge →Running simulations
- 22:1222:12, 6 July 2017 diff hist −9 Clatterbridge →Running the simulation in batch mode with proton.mac macro
- 17:4517:45, 6 July 2017 diff hist +14 Clatterbridge →Running simulations
- 17:4517:45, 6 July 2017 diff hist −130 Clatterbridge →Running simulations
- 17:4317:43, 6 July 2017 diff hist +610 Clatterbridge →Running the simulation
- 17:4017:40, 6 July 2017 diff hist −36 Clatterbridge →Running the simulation
- 16:4916:49, 6 July 2017 diff hist −73 Clatterbridge →Simulation of the Clatterbridge beamline
- 16:3016:30, 6 July 2017 diff hist +329 Clatterbridge →Visualisation
- 16:2916:29, 6 July 2017 diff hist +307 N File:Beamline 500 sim perspective.png Beamline visualised in DAWN v3.90b. The first tube and second box are visualised using the wireframe setting so that their inner components are visible. This simulation contains 500 primary protons. Protons are shown in blue, electrons are red, positrons are cyan, gamma rays are green, neutrons are yellow. current
- 16:2716:27, 6 July 2017 diff hist +764 Clatterbridge →Simulation of the Clatterbridge beamline
- 16:0916:09, 6 July 2017 diff hist +1 Clatterbridge →Simulation of the Clatterbridge beamline
- 16:0616:06, 6 July 2017 diff hist +4 Clatterbridge →Dosimetry box
- 16:0516:05, 6 July 2017 diff hist +792 Clatterbridge →Dosimetry box
- 16:0516:05, 6 July 2017 diff hist +394 N File:Dose monitor exploded.png An exploded view of a dose monitor as used in the dosimetry box. It consists of a set of aluminised mylar foils wedged between layers of perspex to hold them in place. The guard ring is used to create a sealed volume of air between the foils. The aluminium layers face towards the centre of the dose monitor such that the assembly acts as a drift chamber when a potential difference is applied. current
- 15:5315:53, 6 July 2017 diff hist +183 N File:Second box.png A visualisation of the dosimetry box. The box is made of aluminium and contains a brass collimator, two dose monitors and cross wires. The brass nozzle is fixed to the end of the box. current
- 15:3515:35, 6 July 2017 diff hist +84 Clatterbridge →Geometry
- 15:2915:29, 6 July 2017 diff hist +2 Clatterbridge →First aluminium tube
- 15:2815:28, 6 July 2017 diff hist 0 File:First tube 500 sim.png uploaded a new version of "File:First tube 500 sim.png": Increased font size of annotations current
- 15:2515:25, 6 July 2017 diff hist 0 File:First tube 500 sim.png uploaded a new version of "File:First tube 500 sim.png": Added annotations
- 15:2015:20, 6 July 2017 diff hist +554 Clatterbridge →First aluminium tube
- 15:1815:18, 6 July 2017 diff hist +548 N File:First tube 500 sim.png A visualisation of the first tube with 500 primary protons shown as blue tracks. The protons first travel through the collimator, followed by the first scattering foil which spreads out the beam. The brass stopper then blocks out approximately half of the remaining protons before the beam is again spread out through the second scattering foil. The intention is to produce a wide, homogeneous beam. The particles exit the first tube through a Kapton window which is used to keep the tube under vacuum to reduce random scattering off air molecules.
- 15:1115:11, 6 July 2017 diff hist +332 Clatterbridge →First aluminium tube
- 15:0615:06, 6 July 2017 diff hist +177 Clatterbridge →Simulation of the Clatterbridge beamline
- 14:5914:59, 6 July 2017 diff hist +83 Clatterbridge →Simulation of the Clatterbridge beamline
- 14:5614:56, 6 July 2017 diff hist −100 Clatterbridge →Simulation of the Clatterbridge beamline
- 14:5614:56, 6 July 2017 diff hist +5 Clatterbridge →Beamline
- 13:0113:01, 6 July 2017 diff hist −2 Clatterbridge →Beamline