Proton Calorimetry/Meetings/2017/03/29

From PBTWiki
Revision as of 14:11, 29 March 2017 by SimonJolly (talk | contribs)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search

Minutes for UCL Proton Calorimetry Meeting, 29th March 2017 (D17, Physics & Astronomy, UCL)

Present

Simon Jolly, Laurent Kelleter, Anastasia Basharina-Freshville

ABF:

  • Looking at specific peak PMT current:
    • Acquire data with different rates:
    • Calculate average current to compare at what point saturation occurs.
    • Matches predictions almost exactly!
    • Small rise at "saturation" current before drop off.
  • Will pass on information to Hamamatsu to "guide" them in producing lower gain PMTs.

LK:

  • Looking at dose build-up effect in proton therapy and secondary particles.
    • Secondary particles in Geant4 difficult to characterise due to range cut.
    • GetTotalEnergyDeposit() doesn't include energy from secondary particles...
    • Need to check whether 20 micron range cut is short enough with Adam Gibson.
  • Clear build-up effect from secondary protons:
    • Need to check RBE of the resulting short-range protons.
    • Effect of hadronic build-up means Bragg curve incorrect for entrance dose.