AWAKE Simulations
Poster Simulation 09-09-22
Simulation of short driver bunches. Beams are defined directly within the configuration and beamfiles run through lem.py for diagnostics.
Run Number | Base Configuration | Window Width | Window Length | q/m | Total Weight (pC) | LCODE ampl | LCODE Beam Current | LCODE Beam Length | Beam Length (um) | Energy (approx) (GeV) | Comments |
---|---|---|---|---|---|---|---|---|---|---|---|
1 | short_bunch - DAC | 3 | 10 | 1.0 | -2045.504558 | 1 | -3.6 | 0.1 | 3.63 | 30 | Default DAC short_bunch.cfg |
2 | short_bunch - DAC | 3 | 10 | 0.00054 | -2045.504558 | 1 | -3.6 | 0.1 | 3.64 | 30 | Only change made to cfg m/q for protons. Ez plots for 1 and 2 are identical. |
3 | short_bunch - DAC | 3 | 20 | 1.0 | -2045.504558 | 1 | -3.6 | 0.1 | 3.64 | 30 | Plot x-range increases with window length increase. |
4 | short_bunch - DAC | 3 | 100 | 1.0 | -2045.504558 | 1 | -3.6 | 0.1 | 3.63 | 30 | Expecting Ez fall off with distance. Do observe this. |
5 | short_bunch - DAC | 3 | 100 | 0.00054 | -2045.504558 | 1 | -3.6 | 0.1 | 3.64 | 30 | Checking to see if Ez attenuation with distance is different for q/m=1/1836 (proton ). Identical plots. |
6 | short_bunch - DAC | 3 | 20 | 0.00054 | -2045.504558 | -1 | -3.6 | 0.1 | 3.64 | 30 | Can compare this directly with run 3. Identical despite ampl=-1 meaning should be opposite charge. Will set this directly in m/q next. |
7 | short_bunch - DAC | N/A | N/A | N/A | 12.5 | 170 |