Proton Calorimetry/Experimental Runs/2022/ClatterbridgeQuARC
Detector Equipment
- Stack A: 14 clear sheets of scintillator around 2.86 mm thick, with mylar foil for optical isolation, in C-section stack holder and coupled to single Rev. B DDC232 board.
- Stack B: 11 clear sheets and 3 white painted sheets of scintillator with mylar foil for optical isolation (clear sheets), in C-section stack holder and coupled to single Rev. B DDC232 board.
- DAQ using USB104 A7 FPGA and Raspberry Pi (running web GUI).
Preliminary Stack Configurations
Clatterbridge Stack A
1) Sheet Number: 61, thickness: 2.91 mm 2) Sheet Number: 63, thickness: 2.9 mm 3) Sheet Number: 69, thickness: 2.86 mm 4) Sheet Number: 65, thickness: 2.85 mm 5) Sheet Number: 70, thickness: 2.85 mm 6) Sheet Number: 64, thickness: 2.84 mm 7) Sheet Number: 81, thickness: 2.84 mm 8) Sheet Number: 83, thickness: 2.84 mm 9) Sheet Number: 85, thickness: 2.84 mm 10) Sheet Number: 73, thickness: 2.83 mm 11) Sheet Number: 74, thickness: 2.83 mm 12) Sheet Number: 78, thickness: 2.83 mm 13) Sheet Number: 71, thickness: 2.79 mm 14) Sheet Number: 77, thickness: 2.79 mm
Order: 81, 83, 65, 74, 69, 78, 61, 77, 63, 71, 70, 73, 64, 85
Average thickness: 2.843 mm Stack thickness (excluding mylar): 39.8 mm Stack thickness (including mylar): 40.3 mm
Clatterbridge Stack B
1) Sheet Number: 68, thickness: 2.78 mm 2) Sheet Number: 75, thickness: 2.78 mm 3) Sheet Number: 82, thickness: 2.78 mm 4) Sheet Number: 62, thickness: 2.77 mm 5) Sheet Number: 72, thickness: 2.77 mm 6) Sheet Number: 76, thickness: 2.77 mm 7) Sheet Number: 67, thickness: 2.76 mm 8) Sheet Number: 80, thickness: 2.76 mm 9) Sheet Number: 84, thickness: 2.76 mm 10) Sheet Number: 66, thickness: 2.74 mm 11) Sheet Number: 79, thickness: 2.74 mm
12) Sheet Number: 52, thickness: 3.02 mm 13) Sheet Number: 54, thickness: 3 mm 14) Sheet Number: 51, thickness: 2.97 mm
Order: 52, 79, 68, 66, 75, 82, 84, 62, 80, 72, 67, 76, 51, 54
Average thickness: 2.814 mm Stack thickness (excluding mylar): 39.4 mm Stack thickness (including mylar): 39.9 mm
Experiment Plan
- 60 MeV pristine Bragg peak measurements (and with some absorber for different ranges?):
- Stack A front and back.
- Stack B front and back(?)
- SOBP measurements (one type only?):
- Stack A front and back.
- Stack B front and back(?)
Experiment Notes
Run number | Beam Energy (MeV) | Current (nominal) (nA) | Estimated Range (mm) | Spot size (mm, FWHM) | Degrader WET (mm) | DDC232 FSR (pC) | DDC232 Integration Time (us) | Comments | Photodiode QB Fit | Replay Fit |
---|---|---|---|---|---|---|---|---|---|---|
0 | Background | - | - | N/A | - | 350 | 170 (constant) | N/A | ||
1 | Background | - | - | N/A | - | 300 | 170 (constant) | N/A | ||
2 | Background | - | - | N/A | - | 250 | 170 (constant) | N/A | ||
3 | Background | - | - | N/A | - | 200 | 170 (constant) | N/A |