Beam tests of the single module with PRaVDA Silicon strip tracker with trigger pulse output at the Birmingham Cyclotron with a 36 MeV beam.
Equipment List
Item | Notes |
---|---|
Single Module Scintillator Block | 3cm x 3cm x 5cm standard scintillator block. Optical gel required to couple Scintillator to PMT |
Photomultiplier Tube | Hamamatsu R13089 2" |
Portable Enclosure | Modified Peli 1510 Waterproof Wheeled Equipment Case. 230 x 555 x 350mm |
LeCroy HDO6104 Oscilloscope | Records PMT output, connected via SMA-BNC conversion. |
Caen DT5751 Digitiser | Records PMT output, connected via SMA-MCX conversion. Used channel 3. |
DAQ Laptop | Controls Caen HV supply; records data from Caen digitiser. |
Caen NDT1470 HV Supply | Supplies HV to PMT |
PRaVDA Strip Tracker | PRaVDA Unit A, 3x150um Si strip sensors with 90.4um strip pitch. Firmware version update to yield square pulse out when 2 or 3 layers have a strip over threshold per read out cycle |
Control Laptop x 3 | Two used for Remote Desktop control of LeCroy Oscilloscope and DAQ Laptop. Third used for taking down notes. |
Ethernet Switcher | Set in experiment room and connected LeCroy Oscilloscope and DAQ laptop. Output sent to control room Network Hub. |
Network Hub | Set in control room to take output from ethernet switcher. Control laptops connected via ethernet or 5GHz WiFi. |
Ethernet Cable x 3 | To connect 1 control laptop, the LeCroy HDO6104 and DAQ Laptop to their respective network hubs. |
Ethernet Cable | To connect control Network Hub to Ethernet Switcher. |
Male-to-Male SMA Cable | Signal from enclosure port to Splitter |
DC-4200 MHz Signal Splitter | Splits SMA signal to two SMA signals – sent to Oscilloscope and Digitiser. |
Male SMA to Male BNC cable | Sends 1 output from splitter to Oscilloscope. |
Male SMA to Male MCX cable | Sends 1 output from splitter to Digitiser |
USB Cable | Caen HV unit to DAQ Laptop |
Gloves | For handling scintillator |
Optical gel | For coupling scintillator to PMT |
Wipes | For removing optical gel |
Experiment List
28 MeV beam Scattering Foil in 2mm diameter collimator 10kHz rate ~= 160pA onto Transmission Chamber before 2mm collimation
- Bragg Peak Measurements
- Combined scope / digitizer measurements with pristine bragg peak, 100mV trigger threshold
- Combined scope / digitizer measurements with pristine bragg peak, varying trigger threshold
- Degrade beam energy and measure response with 1-6mm PMMA before calorimeter
- PRaVDA box with 2mm collimator, trigger from scope
- PRaVDA box with 2mm collimator for trigger output
36 MeV beam
Scattering Foil in
2mm diameter collimator
10kHz rate ~= 160pA onto Transmission Chamber before 2mm collimation
- Bragg Peak Measurements
- Combined scope / digitizer measurements with pristine bragg peak, 100mV trigger threshold
- Combined scope / digitizer measurements with pristine bragg peak, varying trigger threshold
- Degrade beam energy and measure response with 1-6mm PMMA before calorimeter
- Offset 2mm collimator (by 6mm) for optimal trigger threshold
- Double 2mm collimator (12mm separated) for optimal trigger threshold
- PRaVDA box with 2mm collimator, trigger from scope
- PRaVDA box with 2mm collimator for trigger output
- Degrade beam with 1-6mm PMMA with tracker
Experiment Log
25/10/18
- Set up apparatus as described in equipment list.
- Beam experienced difficulties, delaying data collection.
- Tested trigger output of Tracker into Oscilloscope: square wave of period ~15 ns with amplitude ~400 mV. Pulse example recorded on Oscilloscope disk in folder: SShaikh/Tracker Trigger
- Placed signal splitter for trigger to send to both Digitiser and Oscilloscope. Amplitude reduced to ~50%. Pulse example recorded on Oscilloscope disk in folder: SShaikh/Tracker Trigger (Split)
- Split trigger too small for Digitiser, hence Digitiser set to self-trigger mode.
Beam Tests
Calorimeter files currently located at /unix/pbt/users/dwalker/data/birm_21.02.18 on UCL HEP plus1 server.
PMT Current at HV supply -900 V, beam off: 150 μA
Run Number | High Voltage (V) | Scope Trigger (self trigger, negative edge, mV) | Target Beam Current / Rate | Collimator | Calorimeter Files | Tracker Files | Notes |
---|---|---|---|---|---|---|---|
00 | -900 | -100 | ~10 kHz | 2 mm | run00_2mmCol_160pA_trig100mV | -- |