Proton Calorimetry/Experimental Runs/2018/JanMarPlans

From PBTWiki
Jump to navigation Jump to search

Proton Therapy Range Telescope Plan of Action January–March 2018

Diary

January

  • 22nd–29th Jan: Set up Nikon DSLR camera image acquisition — Laurent. Done.
  • 25th Jan: Painting of scintillator sheets — Anastasia (with Derek). Done.
  • 29th Jan–2nd Feb:
    • Confirm alternative sensor options — Anastasia. We have decided to go with ISDI, so this is not immediately necessary, but keep in mind for the future and maintain contact with Hamamatsu regarding linear image sensors.
    • Retest painted scintillators to check for light deterioration — Anastasia.
    • Construct light cone for light injection tests — Anastasia. Done.
    • Set up Nikon DSLR camera remote image acquisition — Laurent. Done.
    • Mount Nikon DSLR camera to enclosure breadboard — Laurent. Done.
    • Enclosure assembly begins for both enclosures — Simon (with Derek).
  • 31st Jan:
    • First draft of paper circulated — Anastasia.
    • Measure scintillator thickness after painting — Dan, Jordan. Done.

February

  • 5th–9th Feb:
    • Set up sensor readout — Anastasia, Laurent. Done
    • Camera testing carried out: measurement of all scintillator sheets injected with a fibre each and fibres switched around in subsequent measurements in order to confirm non-uniformity is seen due to fibres (and not scintillator), measurements of each scintillator sheet with the same optical fibre for crosstalk studies, measurements of two fibres into two scintillator sheets for crosstalk studies, measurements with LED settings the same as those used for PRIAPUS tests at UCL, measurements of best settings for camera with PRIAPUS LED settings to not saturate the sensor. Analysis ongoing.
    • Further testing (to carry over into next week): measurements with LED settings that saturated the PRIAPUS sensor to determine whether we can adjust camera settings to not saturate the camera, measurements to determine minimum LED settings we can detect with the camera, potential measurements with 207Bi source.
    • Enclosure assembly complete for both enclosures — Simon (with Derek).
  • 10th Feb: Optimal submission deadline for paper (before Ruben and Anastasia go away) — Anastasia.
  • 12th–16th Feb:
    • Construct mechanical support for sensor, assemble in enclosure — Anastasia, Laurent.
    • Testing of sensors and camera within enclosure begins — Anastasia, Laurent.
  • 14th Feb: Second draft of paper circulated — Anastasia.
  • 19th–23rd Feb: Complete testing of sensors and camera within enclosure at UCL — Anastasia, Laurent.
  • 28th February: Submission deadline for paper — Anastasia.

March

  • 8th–9th March: Birmingham test beam.
  • 21st–24th March: MedAustron test beam.

April

  • 19th April: Clatterbridge test beam.

Tasks

Anastasia

  • 25th Jan: Painting of scintillator sheets (with Derek).
  • 29th Jan–2nd Feb:
    • Confirm alternative sensor options.
    • Retest painted scintillators to check for light deterioration.
    • Construct light cone for light injection tests.
  • 31st Jan:
    • First draft of paper circulated.
    • Measure scintillator thickness after painting (with Dan, Jordan).
  • 5th–9th Feb: Set up sensor readout.
  • 10th Feb: Optimal submission deadline for paper (before Ruben and Anastasia go away).
  • 12th–16th Feb:
    • Construct mechanical support for sensor, assemble in enclosure.
    • Testing of sensors and camera within enclosure begins.
  • 14th Feb: Second draft of paper circulated.
  • 19th–23rd Feb: Complete testing of sensors and camera within enclosure at UCL.
  • 28th Feb: Submission deadline for paper.

Laurent

  • 22nd–29th Jan: Set up Nikon DSLR camera image acquisition.
  • 29th Jan–2nd Feb:
    • Set up Nikon DSLR camera remote image acquisition.
    • Mount Nikon DSLR camera to enclosure breadboard.
  • 5th–9th Feb: Set up sensor readout.
  • 12th–16th Feb:
    • Construct mechanical support for sensor, assemble in enclosure.
    • Testing of sensors and camera within enclosure begins.
  • 19th–23rd Feb: Complete testing of sensors and camera within enclosure at UCL.

Simon

  • Confirm dates of beam tests ASAP.
  • 29th Jan–2nd Feb: Enclosure assembly begins for both enclosures (with Derek).
  • 5th–9th Feb: Enclosure assembly complete for both enclosures (with Derek).

Test Beams

Birmingham: 8–9th March

  • Preliminary beam tests at 28–36 MeV.
  • Check experimental setup, DAQ in test environment.
  • Run with both DSLR and pixel sensor in single enclosure: compare output.
  • Check isolation and crosstalk from both DSLR and sensor.
  • Check light output levels and corresponding exposure times for DSLR and sensor.
  • Preliminary test of radiation hardness: monitor radiation dose to sheets.
  • Run tests with both 3 mm sheets and 2 mm sheets but don’t intermingle (no need):
    • Quick test with best 2 mm sheets (save for Clatterbridge).
    • Longer test with 2.6 mm/3 mm sheets to check variation in light output with radiation dose and light levels from sheets.
  • Possibly observe quenching effects for different intensities:
    • Might see nothing as intensity variation comes from different collimators, so dose doesn’t change, just takes up larger volume.
  • Can we see a Bragg peak? Can Laurent reconstruct it? Observe position in Bragg peak with energy variation.
  • Hardware requirements:
    • Light tight enclosure with base for mounting: Zarges case with Thorlabs breadboard installed.
    • Patch panel for cable I/O: DSLR power and USB; pixel sensor power, USB and cameralink.
    • DSLR and associated cabling and software.
    • Pixel sensor and associated cabling and software.
    • All scintillator sheets with 2 bare sides.
    • Vice for holding scintillator.
    • Laptop running remote desktop for camera/sensor acquisition.
    • Network hub and 15 m cable to connect to laptop.
  • Simon to confirm dates with Tony Price.

MedAustron: 21st–24th March

  • Repeat measurements from Clatterbridge up to 100 MeV.
  • Energy limited by 85 mm vice capacity: can we purchase larger vice beforehand?
  • Vary energy from 100 MeV downwards and reconstruct Bragg peak position: repeat 60 MeV measurement (will be 62 MeV but close…).
  • Calibrate scintillator light output:
    • Use 252 MeV beam with absorber behind scintillator stack.
    • Record light output with beam scanned across multiple positions.
    • Carry out calibration on first night.
  • Monitor radiation damage light output and quenching.
  • Make single module measurements for MedAustron to monitor very low rate extraction: only if more than 1 shift available.
  • Hardware requirements for range calorimeter:
    • Light tight enclosure with base for mounting: smaller Peli case with Thorlabs breadboard installed.
    • Mounting hardware to MedAustron couch.
    • Patch panel for cable I/O: sensor USB, power and cameralink.
    • Pixel sensor and associated cabling and software.
    • All scintillator sheets with 1 bare side.
    • Vice for holding scintillator.
    • Laptop running remote desktop for camera/sensor acquisition.
    • Network hub and 20 m cable to connect to laptop.
    • Absorber behind scintillator stack?
  • Hardware requirements for single module:
    • Light tight enclosure with base for mounting: repurpose Zarges case.
    • Mounting hardware to MedAustron couch.
    • Patch panel for cable I/O: needs signal and BNC HV.
    • LeCroy scope plus Caen digitiser.
    • Caen portable HV.
    • PMT and scintillator for 252 MeV.
    • Long BNC and HV cables in case we want to run with the scope outside the treatment room.
    • Scope running in mode to monitor trigger rate.
  • Simon to confirm dates with Claus Schmitzer.

Clatterbridge: 19th April

  • Beam test at 60MeV clinical energy: target of grant.
  • Primary tests at 60 MeV with variation down using wheel modulator.
  • Reconstruct peak at 60 MeV.
  • Observe changes in Bragg peak depth and whether there is any change in the shape of the peak.
  • Observe variations in light output and peak shape with beam intensity:
    • Use cyclotron source to vary intensity, so changing dose.
    • Monitor radiation hardness and quenching.
  • Make a measurement at 60 MeV at clinical rate with 3 different groups of sheets.
  • Refine acquisition parameters for clinical rate for sensor and DSLR.
  • Hardware requirements: identical setup to Birmingham but longer network cable required.
  • Simon to confirm dates with Andrzej Kacperek.

Task List

Single module paper: Anastasia

  • First full draft circulated by 31st January.
  • Second draft circulated by 14th February (or sooner if main corrections are only wording etc. rather than content and plots).
  • Submit to journal by 28th February.
  • Ideal submission by 10th February (before Ruben goes away).

Sensor selection and readout: Anastasia, Laurent

  • PRIAPUS sensor used for previous tests has several drawbacks:
    • Large enclosure that is mechanically difficult to fix in confined space.
    • Bare sensor that is difficult to couple to.
    • Sensor requires a pair of cameralink cables with bespoke PCI card.
    • Assembly likely too large to ship to MedAustron.
  • ISDI can provide range of commercial sensors:
    • Best options 5 x 10 cm and 15 x 10 cm: the latter probably suits our purposes.
    • Meeting on 25th January with Simon and Laurent at ISDI in Kentish Town: very promising options.
    • ISDI will provide details of all sensor options and readout methods: Laurent will liaise with them and look after sensor assembly, readout, DAQ and cabling.
  • Alternative possibilities still need pursuing:
    • Hamamatsu.
    • Teledyne Dalsa.
    • Varex.
    • Rayence.
    • Anastasia will chase up during week of 29th January.
  • Coupling via Fibre Optic Plate (FOP) to scintillator:
    • ISDI provide FOP already glued to sensor.
    • Unclear whether alternative manufacturers can provide similar.
  • Sensor needs to be read out using laptop connected via remote desktop: Anastasia and Laurent set up sensor readout week of 5th February.
  • Mechanical structure to support sensor within enclosure:
    • Anastasia and Laurent to liaise with Derek.
    • Begin assembly week of 12th February: will depend on arrival of sensor.

Nikon DSLR and readout: Laurent

  • Nikon D70 DSLR borrowed from Adam Gibson in Medical Physics.
  • Camera used as corroborative image with sensor.
  • Mounted in same enclosure viewing scintillator at 90 degrees.
  • Powered by mains with proprietary Nikon connector: battery doesn’t work.
  • Controlled via USB using open source software.
  • Laurent to set up software and acquire images week of 22nd January.
  • Laurent to set up camera for remote acquisition week of 29th January.
  • Camera needs mounting into enclosure to optical breadboard.
  • Laurent to mount camera and check mechanical setup week of 29th January.

Scintillator sheets drilling holes: Anastasia

  • In order to carry out tests at UCL we want to be able to inject light into the scintillator sheets.
  • We want to be able to measure all 30 sheets at once, this could be useful. Therefore:
    • Construct a light cone (like the one used for SuperNEMO in dark cupboard in D27) to distribute one LED to 30 optical fibres so that all sheets can have an LED input.  Should take 2-3 days to construct. Week of 29th January or later, depending on whether we need to. Anastasia (with Derek).  Note: currently we are able to measure two at a time in a “portable” scenario using light cone constructed previously by Derek and myself.
    • OR
    • Use the current light cone in the dark cupboard in D27 for tests at UCL – should take 1 day to set up – Anastasia, week of 5th February.
  • If we want to be able to bring the LED with us for emergency tests at test beams, on the patch panel that will be made up for the flight case remember to include a hole large enough to fit 30 fibres through, with an option of a "shutter" to make the case light tight when not testing with an LED. Remember we already have a light cone we can bring with us so we should put at least one optical fibre connector on the patch panel.
  • Drill holes in 2 mm sheets – I have checked with Derek and this can be done on the thin scintillators, with care.  The drilling must be done before painting, then the hole can be masked off during painting.  Thursday 25th January –Anastasia (with Derek).

Scintillator sheets painting: Anastasia

  • Three types of paint currently being tested:
    • Chalkboard paint (painted on 08/01/18) – scintillator looks healthy!
    • Halfords Satin Black aerosol paint (painted on 12/01/18) – scintillator looks healthy!
    • Model paint (painted on 12/01/18) – scintillator looks healthy!
  • Halfords satin black spray chosen for scintillators: so far no bad effects seen on the scintillator. An original NUVIA 3mm enhanced scintillator sheet has been tested before and after spraying and everything looks good.
    • Anastasia to test again towards the end of the week of 29th January/beginning of 5th February to make sure light collection hasn’t deteriorated.
  • Painting of new sheets to be started on Monday 29th January – estimate around 1-2 days, depending on fumes in the room etc., to complete: Anastasia (with Derek).
  • Scintillator sheet thickness should be ready to be re-measured by Dan and Jordan on Wednesday 31st January. 


Detector enclosures and flight cases: Simon

  • Derek has purchased and modified a vice to hold a scintillator stack of up to 85 mm.
  • Two flight cases purchased by Simon.
  • Optical plate for base of both enclosures needs to be ordered.
  • Construct case and mount setup week of 29th January and 5th February – talk about design 
and what needs to be in the case (connector types on patch panels etc.) once sensor is decided.
  • Order patch panel connectors and cut window for beam entrance.
  • Full assembly ready by 9th February. 

  • Simon will liaise with Derek regarding construction of enclosures.

Progress

  • 3 waterproof and wheeled flight cases ordered and delivered from RS:
    • Large Zarges case for single module setup: 800x500x385mm
    • Medium Zarges case for range calorimeter tests: 600x400x386mm
    • Small Peli case for carrying range calorimeter in hand luggage without Nikon DSLR: 230 x 555 x 350mm
  • Medium Zarges case painted black and ready for patch panel installation.
  • Thorlabs optical breadboards ordered for each case:
    • Breadboard for medium case cut down to size.
    • Large breadboard slightly too large to fit over lip of case...
  • Patch panel connectors for single module case arrived:
    • Huber and Suhner SMA.
    • BNC signal.
    • We already have SHV connector.
  • DSLR camera mount recycled from tripod (thanks Spectrum!).
  • DSLR cables for USB patch panel arrived from RS: USB male A to male A and USB male A to male mini B.

To Do

  • Paint large Zarges case.
  • Cut down optical breadboard for large Zarges case.
  • Install optical breadboards in flight cases.
  • Design mounts to allow Zarges cases to mount securely to MedAustron couch (Markus Stock has provided specs).
  • Cut and protect holes for beam entry:
    • Black out holes with paper/card/cloth/LX tape.
    • Protect hole with aluminium plate/flap.
  • Spec connectors for range calorimeter patch panel:
    • Sensor power (4-pin DIN?).
    • Sensor signal (USB2, USB3, Camera Link?).
    • Sensor trigger (SMA?).
    • DSLR power: mains plug (may not be necessary with new battery).
    • DSLR signal: USB2 (will USB3 work?).
  • Order remaining connector cables.
  • Cover for patch panel connectors.
  • Order larger wheels for both Zarges cases.

Testing at UCL: Laurent, Anastasia

  • Anticipate everything to be assembled by 9th February.
  • 10th–18th February Anastasia away: Laurent can start to carry out tests at UCL the week of the 12th February – we can go over how and what before that etc.
  • Continue tests (Anastasia and Laurent) during the week of the 19th February.  Tests to think 
about, with both the acquired sensor and the DSLR camera:
    • Light injection into each scintillator slice with clear record of the test setup (LED voltage and other pulser settings, sensor settings etc.) and the peak and sigma measured for each scintillator sheet.
    • This could be a test to help us see if there is any radiation damage after the stack has been in the test beams: compare values measured before and after test beam for the same settings.
    • 207Bi test if we have time – more details from Ruben.
    • Test of sensor “linearity”:
      • Scan across different LED voltages.
      • Take different frame times.
      • Test dynamic range of sensor.