Proton Calorimetry/Meetings/2017/07/18: Difference between revisions
SimonJolly (talk | contribs) (Created page with "== Minutes for UCL Proton Calorimetry Meeting, 5th July 2017 (D107, Physics & Astronomy, UCL) == === Present === '''Simon Jolly''', '''Anastasia Basharina-Freshville''', '''Rub...") |
SimonJolly (talk | contribs) No edit summary |
||
Line 10: | Line 10: | ||
** Measure peak and average anode current with LEDs. | ** Measure peak and average anode current with LEDs. | ||
** Check low rate performance first, then increase rate to check whether distortion occurs above 1MHz. | ** Check low rate performance first, then increase rate to check whether distortion occurs above 1MHz. | ||
* | ** Gated PMT will require a bit more thought... | ||
* Scintillator sheets also shipped from Nuvia: | |||
** Samples of 100x100x10mm, standard and pTP enhanced composition, 0.3mm foil to be cut as needed. | |||
** Also 3mm pressed material included. | |||
* WaveCatcher documentation for hardware and software available from Orsay: | |||
** 2–64 channel versions available. | |||
** Seems similar to Caen but with access to firmware. | |||
'''ABF''': | '''ABF''': | ||
* | * Applied bias voltage to photodiode preamp: signal increases, so does noise... | ||
* Will check photodiode with 1–100 ms integration windows. | |||
* | * Will also check maximum integration window for Caen DT5740D QDC 16-channel digitiser. | ||
* Will | |||
'''SJ''': | '''SJ''': | ||
Line 25: | Line 29: | ||
** Waiting on 2:1 Mini-Circuits splitter. | ** Waiting on 2:1 Mini-Circuits splitter. | ||
** Various lengths of Huber and Suhner SMA cable borrowed from '''John Mitchell''' (UCL Electrical Engineering). | ** Various lengths of Huber and Suhner SMA cable borrowed from '''John Mitchell''' (UCL Electrical Engineering). | ||
* Will email '''Ferruccio Renzoni''' and '''Peter Barker''' regarding coupling of photodiodes to electronics. |
Revision as of 13:45, 18 July 2017
Minutes for UCL Proton Calorimetry Meeting, 5th July 2017 (D107, Physics & Astronomy, UCL)
Present
Simon Jolly, Anastasia Basharina-Freshville, Ruben Saakyan
RS:
- PMT bases are on their way from Hamamatsu!
- Start with testing dynode 4 and 5.
- Measure peak and average anode current with LEDs.
- Check low rate performance first, then increase rate to check whether distortion occurs above 1MHz.
- Gated PMT will require a bit more thought...
- Scintillator sheets also shipped from Nuvia:
- Samples of 100x100x10mm, standard and pTP enhanced composition, 0.3mm foil to be cut as needed.
- Also 3mm pressed material included.
- WaveCatcher documentation for hardware and software available from Orsay:
- 2–64 channel versions available.
- Seems similar to Caen but with access to firmware.
ABF:
- Applied bias voltage to photodiode preamp: signal increases, so does noise...
- Will check photodiode with 1–100 ms integration windows.
- Will also check maximum integration window for Caen DT5740D QDC 16-channel digitiser.
SJ:
- SMA components mostly here:
- High quality Huber and Suhner components ordered for proton calorimetry; LOTS of less expensive (but still decent) spares available within group.
- SMA-BNC and SMA-MCX adapters all arrived.
- Waiting on 2:1 Mini-Circuits splitter.
- Various lengths of Huber and Suhner SMA cable borrowed from John Mitchell (UCL Electrical Engineering).
- Will email Ferruccio Renzoni and Peter Barker regarding coupling of photodiodes to electronics.