Proton Calorimetry/Meetings/2017/07/18: Difference between revisions

From PBTWiki
Jump to navigation Jump to search
(Created page with "== Minutes for UCL Proton Calorimetry Meeting, 5th July 2017 (D107, Physics & Astronomy, UCL) == === Present === '''Simon Jolly''', '''Anastasia Basharina-Freshville''', '''Rub...")
 
No edit summary
Line 10: Line 10:
** Measure peak and average anode current with LEDs.
** Measure peak and average anode current with LEDs.
** Check low rate performance first, then increase rate to check whether distortion occurs above 1MHz.
** Check low rate performance first, then increase rate to check whether distortion occurs above 1MHz.
*  
** Gated PMT will require a bit more thought...
* Scintillator sheets also shipped from Nuvia:
** Samples of 100x100x10mm, standard and pTP enhanced composition, 0.3mm foil to be cut as needed.
** Also 3mm pressed material included.
* WaveCatcher documentation for hardware and software available from Orsay:
** 2–64 channel versions available.
** Seems similar to Caen but with access to firmware.


'''ABF''':
'''ABF''':
* Running preliminary tests with photodiode circuit using Hamamatsu preamp.
* Applied bias voltage to photodiode preamp: signal increases, so does noise...
* Hamamatsu finally provided correct resistor for preamp! 100 kΩ.
* Will check photodiode with 1–100 ms integration windows.
* Looking after summer students for Monday–Wednesday next week (Laurent Wednesday).
* Will also check maximum integration window for Caen DT5740D QDC 16-channel digitiser.
* Still waiting for response from Hamamatsu regarding low gain PMTs; modified PMTs and bases not yet arrived.
* Will chase up 10 mm sheets from Nuvia.


'''SJ''':
'''SJ''':
Line 25: Line 29:
** Waiting on 2:1 Mini-Circuits splitter.
** Waiting on 2:1 Mini-Circuits splitter.
** Various lengths of Huber and Suhner SMA cable borrowed from '''John Mitchell''' (UCL Electrical Engineering).
** Various lengths of Huber and Suhner SMA cable borrowed from '''John Mitchell''' (UCL Electrical Engineering).
* Will email '''Ferruccio Renzoni''' and '''Peter Barker''' regarding coupling of photodiodes to electronics.

Revision as of 13:45, 18 July 2017

Minutes for UCL Proton Calorimetry Meeting, 5th July 2017 (D107, Physics & Astronomy, UCL)

Present

Simon Jolly, Anastasia Basharina-Freshville, Ruben Saakyan

RS:

  • PMT bases are on their way from Hamamatsu!
    • Start with testing dynode 4 and 5.
    • Measure peak and average anode current with LEDs.
    • Check low rate performance first, then increase rate to check whether distortion occurs above 1MHz.
    • Gated PMT will require a bit more thought...
  • Scintillator sheets also shipped from Nuvia:
    • Samples of 100x100x10mm, standard and pTP enhanced composition, 0.3mm foil to be cut as needed.
    • Also 3mm pressed material included.
  • WaveCatcher documentation for hardware and software available from Orsay:
    • 2–64 channel versions available.
    • Seems similar to Caen but with access to firmware.

ABF:

  • Applied bias voltage to photodiode preamp: signal increases, so does noise...
  • Will check photodiode with 1–100 ms integration windows.
  • Will also check maximum integration window for Caen DT5740D QDC 16-channel digitiser.

SJ:

  • SMA components mostly here:
    • High quality Huber and Suhner components ordered for proton calorimetry; LOTS of less expensive (but still decent) spares available within group.
    • SMA-BNC and SMA-MCX adapters all arrived.
    • Waiting on 2:1 Mini-Circuits splitter.
    • Various lengths of Huber and Suhner SMA cable borrowed from John Mitchell (UCL Electrical Engineering).
  • Will email Ferruccio Renzoni and Peter Barker regarding coupling of photodiodes to electronics.