| == Minutes for UCL Proton Beam Therapy Group Meetings, 4th February ==
| |
|
| |
|
| === Present ===
| |
|
| |
| '''Joe Bateman''', '''Sonia Escribano''', '''Simon Jolly''', '''Raffaella Radogna (via Teams)''', '''Kirsty Hall (from Hamamatsu)'''
| |
|
| |
| * Discussion with Kirsty Hall from Hamamatsu about photodiode arrays for scintillating fibre array to allow for better integration with QuARC.
| |
| * Kirsty to investigate two possible routes for going forward:
| |
| ** Possibility of having on board DDC or way of connecting S13885-128 photodiode array to DDC board.
| |
| ** Possibility of having surface mounted photodiodes (such as S12859-021) shrunk to a smaller size so that pixel pitch is comparable with 0.5mm fibre diameter.
| |
| * Also will look into questions Raffy has a about current experience with S13885-128 photodiode array, i.e.:
| |
| ** If observed response at saturation (e.g., decreasing signal rather than plateau or charge sharing among neighbours) is expected
| |
| ** How response of individual photodiodes within array vary and how to characterise this.
| |
|
| |
| === [[ELogs/RaffaellaRadogna|Raffaella Radogna]] ===
| |
|
| |
| * Discussed with Bari mech eng Producing second prototype with resin material harry suggested - use inventor files (should be able to open fusion) will share with them once harry has finished with the fusion file
| |
| * Produce 2 new prototypes (frame + fibres + screws etc) and have one sent here
| |
| * Beam test in Trento
| |
| ** ~5s per beam
| |
| ** 10 beam deliveries each for CONV and UHDR calibrations (but may only need 8)
| |
| ** Background measurement at FSR for 12.5pC acquisition and for for FLASH
| |
| ** Happy to cut out as many pristine Bragg peaks as necessary to keep within FLASH time limits at Trento
| |
| ** I.e. 1 minute = 12 Bragg peaks at ~5s per measurements
| |
| ** Or Bragg peaks at lower measurement time per FLASH Bragg peak (i.e. <5 s)
| |
| ** Spot scanning at CONV dose rates
| |
| ** Potentially WET measurement of fibres at next UCLH if using giraffe on new QuARC electronics
| |
|
| |
|
| |
| === [[ELogs/SoniaEscribano|Sonia Escribano]] ===
| |
|
| |
| * Looking at new calibration method - now works with txt file that is generated with calibration values
| |
| * Problem with calibration
| |
| ** Need calibRMS - need separate file with these values?
| |
| *** Important for the fit
| |
| *** Include rms beneath calibration coefficients
| |
| ** How do we save name of header file for calibration file
| |
| ** Include in header file which files were used to generate calibration coefficients
| |
|
| |
| * In new file structure maybe have new file directory for background data, i.e. calibration, background, date
| |
| ** For now do it manually
| |
| * New calibration and fitting procedure
| |
| ** generate calibration txt files using shoot throughs
| |
| ** Apply calibration values generates calibrated txt with every single measurement
| |
| ** Fit data averaged at 25 Hz -read calibrated data and fit at desired frequency (default 25hz)
| |
| * Things for new experiment
| |
| ** Raw data = 160*8 (hex length and 8 modules)
| |
| ** Calibration: 4 calibration_i files
| |
| ** Calibrate data
| |
| ** Initially split the raw data in two files for each Bragg peak
| |
| * Messaged harry about scintillators waiting to hear from John and Wayne but still hasn't sent them scintillator sheets yet
| |
| * Simon and Sonia to check final design on fusion
| |
|
| |
| * How do you ensure consistency between modules if there's difference in coupling etc
| |
| ** Take Manchester data and do shoot-through calibration in current way then apply it to one of the shoot-through calibration files and see how it looks for each module (i.e. treat each module independently)
| |
| ** Need to find a way to scale to dose in each of the modules
| |
|
| |
|
| |
| === [[ELogs/JoeBateman|Joe Bateman]] ===
| |