Proton Calorimetry/Meetings/2023/03/15: Difference between revisions
SaadShaikh (talk | contribs) No edit summary |
SaadShaikh (talk | contribs) No edit summary |
||
Line 6: | Line 6: | ||
=== [[ELogs/SaadShaikh|Saad Shaikh]] === | === [[ELogs/SaadShaikh|Saad Shaikh]] === | ||
*Delivered update on Geant4 simulation development, slides can be found here. | *Delivered update on Geant4 simulation development, slides can be found [http://www.hep.ucl.ac.uk/pbt/wikiData/presentations/2023/SS230315_Geant4.pptx here]. | ||
**Found a list of values for Gaussian energy straggling to produce curves similar to those measured at UCLH, across clinical energy range. | **Found a list of values for Gaussian energy straggling to produce curves similar to those measured at UCLH, across clinical energy range. | ||
**Added detector messenger to allow Birks' constant to be set at runtime. | **Added detector messenger to allow Birks' constant to be set at runtime. | ||
*Gave presentation on analysis on PARTREC beam test, slides can be found here. | *Gave presentation on analysis on PARTREC beam test, slides can be found [http://www.hep.ucl.ac.uk/pbt/wikiData/presentations/2023/SS230315_PARTREC.pptx here]. | ||
**Beam quality worsens at lower energies, possibly due to aluminium beam degrader. | **Beam quality worsens at lower energies, possibly due to aluminium beam degrader. | ||
**Appear to have linear scaling of average charge measured with beam current. | **Appear to have linear scaling of average charge measured with beam current. |
Latest revision as of 10:18, 16 March 2023
Minutes for UCL Proton Calorimetry Meetings, 15th March
Present
Saad Shaikh, Simon Jolly, Sonia Escribano, Maya Maciurzynska
Saad Shaikh
- Delivered update on Geant4 simulation development, slides can be found here.
- Found a list of values for Gaussian energy straggling to produce curves similar to those measured at UCLH, across clinical energy range.
- Added detector messenger to allow Birks' constant to be set at runtime.
- Gave presentation on analysis on PARTREC beam test, slides can be found here.
- Beam quality worsens at lower energies, possibly due to aluminium beam degrader.
- Appear to have linear scaling of average charge measured with beam current.
- Fit results do vary with different beam current: effect is more pronounced at lower (worse) energies, best results still have 0.1-0.2 mm difference in range.
- There is some interplay with Birks' constant and range – worse values of Birks' constant give worse range results.
- Possibly have 0.8mm systematic offset from reference data, but need more reference data to confirm.
- Programmed flash memory on USB104 board so that device is programmed with DDC232 code on power-up.
- Updated Raspberry Pi and loaded latest versions of DAQ code: set up works with Sonia's GUI.
- Will start PBT journal club with Sonia to start consolidating research from other groups on scintillators for proton therapy & ionisation quenching.
- Organised first meeting of UCL HEP Climate Change projects and drafted a call for proposals for 4 small funded projects for PhD students.