Proton Calorimetry/Experimental Runs/2021/Nov2: Difference between revisions

From PBTWiki
Jump to navigation Jump to search
Line 22: Line 22:
|-
|-
| style="text-align: center;" | Scintillator stack
| style="text-align: center;" | Scintillator stack
| style="text-align: center;" | X x 10 mm, Y x 10 mm and Z x (approx) 2.8 mm sheets in ascending order from the front/beam of the end of the scintillator. Sheet numbers from front to end (in beam direction): 51, 5, 54, 3, 45, 1, 31, 50, 49, 44, 39, 9, 42, 33, 46, 47, 38, 37, 40, 8, 32, 43, 34, 41, 52, 6, 55, 4, 35, 11, 36, 24. Full stack thickness measurements (in mm): 91.61, 91.65.
| style="text-align: center;" | X x 10 mm, Y x 10 mm and Z x (approx) 2.8 mm sheets in ascending order from the front/beam of the end of the scintillator. Sheet numbers from front to end (in beam direction): 51, 5, 54, 3, 45, 1, 31, 50, 49, 44, 39, 9, 42, 33, 46, 47, 38, 37, 40, 8, 32, 43, 34, 41, 52, 6, 55, 4, 35, 11, 36, 24. Full stack thickness measurements (in mm): 90.61, 90.65.
|-
|-
| style="text-align: center;" | Nikon D7500
| style="text-align: center;" | Nikon D7500

Revision as of 17:26, 10 November 2021

Afternoon test at UCLH with photodiodes.

Experiment Equipment

Item Notes
Network Hub Set in control room to take output from experimental room ethernet connection. Control laptops connected via 5GHz WiFi.
Control Laptop x2 1 for remote control for sensor and FPGA, 1 for notes/web GUI.
Ethernet Cable x 3 To connect DAQ laptops to network in the experimental room, network hub to network in control room.
Portable Enclosure Modified Big Zarges Waterproof Wheeled Equipment Case.

Features mount for scintillator stack, front and back openings for beam, patch panel with ports for SHV, BNC, SMA, USB, Camera Link cables.
Hole for sensor powering.
Mylar windows with Al support mounted to internal face: approximately light-tight.

Scintillator stack X x 10 mm, Y x 10 mm and Z x (approx) 2.8 mm sheets in ascending order from the front/beam of the end of the scintillator. Sheet numbers from front to end (in beam direction): 51, 5, 54, 3, 45, 1, 31, 50, 49, 44, 39, 9, 42, 33, 46, 47, 38, 37, 40, 8, 32, 43, 34, 41, 52, 6, 55, 4, 35, 11, 36, 24. Full stack thickness measurements (in mm): 90.61, 90.65.
Nikon D7500 Connected to DAQ Laptop via USB cable.
DAQ laptop x1 Control sensor and photodiode acquisition.
Nexys Video FPGA development board. For interfacing between DDC232 and PC.
Rev. 2 Texas Instruments DDC232 custom circuit board (x2) Each housing 16x Hamamatsu S12915-16R photodiodes, coupled directly to scintillator sheets with optical gel. Aligned by eye to scintillator sheets.
Gloves For handling scintillator
Optical Gel For photodiode-scintillator optical coupling

Schematic

UCL_Setup.png

DDC232 Instructions

  • Bash script prog.sh executes FTDI.cpp and livePlot.cpp. Execute with . prog.sh 2 350 0 170 0 50 true 20211102/capture.txt in the directory Photodiodes.
    • First argument is the number of DDC232s.
    • Second argument is the full-scale range (FSR) in pC. Choices are: 12.5, 50, 100, 150, 200, 250, 300, 350.
    • Third argument is the y-scale for the ROOT display. Set to 0 for default.
    • Fourth argument is the integration time in us. Range is 170-1455. Set in multiples of 5 us.
    • Fifth argument is the number of measurements to acquire. Typically acquire 5700 measurements per second. Set to 0 for infinite loop.
    • Sixth argument is the rate in Hz to update the file average.csv for ROOT/web GUI plotting.
    • Seventh argument is a boolean to choose whether to display the ROOT plot.
    • Eighth argument is the filename and destination for the output hexadecimal data.
  • After acquisition, close ROOT by choosing File->Quit in the ROOT window and then stopping DAQ (if in infinite loop) with CTRL-C.
  • To perform a fit while acquiring data, add the following arguments: fit 20211103 background.txt backST.txt frontST.txt
    • Ninth argument enables fit option
    • Tenth argument is the folder containing background and shoot-through measurements.
    • Eleventh, twelfth, thirteenth argument are the background, back shoot-throughs and front shoot-throughs respectively.

Experiment Plan

  • Background & calibration shoot-throughs (background at all 8 DDC232 full-scale ranges)
  • Pencil beams, 70-110 MeV, 5 MeV steps, 2 currents (high/low)
  • Live fit demo: pencil beam 100-110 MeV
  • Treatment plan: range steps, 110 MeV-70 MeV, 1 MeV steps, no x-y scanning (demo live fit)
  • ±1, 2, 3, 4mm in x-y planes, 100 MeV
  • Detector misalignment, ±2°, ±5°, ±10° 100 MeV

Experiment Notes

Range calorimeter measurements with Nikon camera + photodiodes.

Images from camera: /unix/pbt/data/uclh/20211102/Nikon

Photodiode hexadecimal data: /unix/pbt/data/uclh/20211102/DDC232

Run number Beam Energy (MeV) Estimated Range (mm) Current (nA) Spot size (mm, FWHM) DDC232 FSR (pC) DDC232 Integration Time (us) Degrader WET (mm) Comments QB Fit
0 Background N/A N/A N/A 350 170 0 room light on N/A
1 Background N/A N/A N/A 300 170 0 room light on N/A
2 Background N/A N/A N/A 250 170 0 room light off N/A
3 Background N/A N/A N/A 200 170 0 room light off N/A
4 Background N/A N/A N/A 150 170 0 room light off N/A
5 Background N/A N/A N/A 100 170 0 room light off N/A
6 Background N/A N/A N/A 50 170 0 room light off N/A
7 Background N/A N/A N/A 12.5 170 0 room light off N/A
8 240 354 13 8.2 12.5 170 57 RH shoot through; 90 degree gantry; room light off N/A
9 240 354 13 8.2 12.5 170 57 LH shoot through; 270 degree gantry; room light off N/A
10 110 91.3 300 10.66 12.5 170 0 Range test; 270 degree gantry; room light off N/A
11 105 - 300 - 12.5 170 0 Range test; 270 degree gantry; room light off N/A
12 100 77.1 350 11.20 12.5 170 0 Range test; 270 degree gantry; room light off N/A
13 95 - 350 - 12.5 170 0 Range test; 270 degree gantry; room light off N/A
14 90 63.9 350 11.77 12.5 170 0 Range test; 270 degree gantry; room light off N/A
15 85 - 350 - 12.5 170 0 Range test; 270 degree gantry; room light off N/A
16 80 51.8 350 12.62 12.5 170 0 Range test; 270 degree gantry; room light off N/A
17 75 - 350 - 12.5 170 0 Range test; 270 degree gantry; room light off N/A
18 110 91.3 300 10.66 12.5 170 0 Live fit test; 50s acquisition; 270 degree gantry; room light off N/A
19 105 - 350 - 12.5 170 0 Live fit test; 200s acquisition; 270 degree gantry; room light off N/A
20 110 91.3 300 10.66 12.5 170 0 Live fit test; 200s acquisition; 270 degree gantry; room light off N/A
21 100 77.1 350 11.20 12.5 170 0 Live fit test; 200s acquisition; 270 degree gantry; room light off N/A
22 110-70 - 10 MU/spot - 12.5 170 0 Range plan: 10 MU/spot, 110-70 MeV in 1 MeV steps; 270 degree gantry; room light off N/A
23 110-70 - 200 MU/spot - 12.5 170 0 Range plan: 200 MU/spot, 110-70 MeV in 1 MeV steps; 270 degree gantry; room light off N/A
24 110-70 - 200 MU/spot - 12.5 170 0 Range plan: 200 MU/spot, 110-70 MeV in 1 MeV steps; 270 degree gantry; room light off N/A
25 100 77.1 350 11.20 12.5 170 0 Offset test: detector down/beam high 1cm; 270 degree gantry; couch height at -15.7cm; room light off N/A
26 100 77.1 350 11.20 12.5 170 0 Offset test: detector down/beam high 2cm; 270 degree gantry; couch height at -16.7cm; room light off N/A
27 100 77.1 350 11.20 12.5 170 0 Offset test: detector down/beam high 3cm; 270 degree gantry; couch height at -17.7cm; room light off N/A
28 100 77.1 350 11.20 12.5 170 0 Offset test: detector down/beam high 4cm; 270 degree gantry; couch height at -18.7cm; room light off N/A
29 100 77.1 350 11.20 12.5 170 0 Offset test: detector right/beam left -1cm; 270 degree gantry; couch height at -14.7cm, in/out at 50.5; room light off N/A
30 100 77.1 350 11.20 12.5 170 0 Offset test: detector right/beam left -2cm; 270 degree gantry; couch in/out at 49.5; room light off N/A
31 100 77.1 350 11.20 12.5 170 0 Offset test: detector right/beam left -3cm; 270 degree gantry; couch in/out at 48.5; room light off N/A
32 100 77.1 350 11.20 12.5 170 0 Offset test: detector right/beam left -4cm; 270 degree gantry; couch in/out at 47.5; room light off N/A
33 100 77.1 350 11.20 12.5 170 0 Offset test: detector left/beam right +1cm; 270 degree gantry; couch in/out at 52.5; room light off N/A
34 100 77.1 350 11.20 12.5 170 0 Offset test: detector left/beam right +2cm; 270 degree gantry; couch in/out at 53.5; room light off N/A
35 100 77.1 350 11.20 12.5 170 0 Offset test: detector left/beam right +3cm; 270 degree gantry; couch in/out at 54.5; room light off N/A
36 100 77.1 350 11.20 12.5 170 0 Offset test: detector left/beam right +3cm; 270 degree gantry; couch in/out at 54.5; 50s acquisition; room light off N/A
37 100 77.1 350 11.20 12.5 170 0 Offset test: detector left/beam right +4cm; 270 degree gantry; couch in/out at 55.5; 50s acquisition; room light off N/A
38 100 77.1 350 11.20 12.5 170 0 Offset test: horizontal 10 degree offset; 270 degree gantry; room light off N/A
39 100 77.1 350 11.20 12.5 170 0 Offset test: horizontal 5 degree offset; 270 degree gantry; room light off N/A
40 100 77.1 350 11.20 12.5 170 0 Offset test: horizontal 2 degree offset; 270 degree gantry; room light off N/A
Image number Beam Energy (MeV) Estimated Range (mm) Current (nA) Spot size (mm, FWHM) Shutter Speed (s) Aperture ISO Degrader WET (mm) Comments Image
DSC_1628 160 125 1 f3 ISO100 0
DSC_1629 150 125 2 f3 ISO100 0
DSC_1630 150 125 5 f3 ISO100 0
DSC_1631 150 125 2.5 f3 ISO100 0
DSC_1632 150 125 2 f3 ISO100 0
DSC_1633 150 125 1.6 f3 ISO100 0
DSC_1634 140 165 1 f3 ISO100 0
DSC_1635 140 165 0.5 f3 ISO100 0
DSC_1636 130 200 0.5 f3 ISO100 0
DSC_1637 130 200 0.25 f3 ISO100 0
DSC_1638 120 270 0.5 f3 ISO100 0
DSC_1639 120 270 0.25 f3 ISO100 0
DSC_1640 120 270 1 f3 ISO100 0
DSC_1641 120 270 2 f3 ISO100 0