Proton Calorimetry/Experimental Runs/2020/Nov27: Difference between revisions

From PBTWiki
Jump to navigation Jump to search
Line 38: Line 38:
|9|| 170us || 350pC FSR || PDs: S12915-16R|| Raffy's office D106: DDC232 board with PD placed OUTSIDE the box. UV torch.
|9|| 170us || 350pC FSR || PDs: S12915-16R|| Raffy's office D106: DDC232 board with PD placed OUTSIDE the box. UV torch.
|-
|-
|10|| 170us || 350pC FSR || PDs: S12915-16R|| D109, Dark Measurement, PELI Case (15/12/20), saved as Run47 on Saad's laptop.
|10|| 170us || 350pC FSR || PDs: S12915-16R|| D109, Dark Measurement, PELI Case (15/12/20).
|-
|-
|11|| 170us || 350pC FSR || PDs: S12915-16R|| D27, Dark Measurement, PELI Case (15/12/20), saved as Run48 on Saad's laptop.
|11|| 170us || 350pC FSR || PDs: S12915-16R|| D27, Dark Measurement, PELI Case (15/12/20).
|-
|-

Revision as of 15:19, 15 December 2020

27 Nov 2020


Dark noise measurements in different rooms at UCL and with different conditions

Setup: - PD array exposed to dark - some runs have noise level recorded with PD unplugged

Aim: Measure the dark noise with different conditions. The spikes visible for all runs recorded inside D27 might come from noise

list of runs in this file unix/pbt/data/ucl/20201127/20201127_LEDandADCBoard.xlsx data saved in unix/pbt/data/ucl/20201027/

Run DDC int time DDC Full scale Photodiodes Notes
1 170us 350pC FSR PDs: S1337-16BR Lab D27: dark room. DDC232 board with PD placed INSIDE the box, close to the patch panel holes (probably getting some light).
2 170us 350pC FSR PDs: S12915-16R Lab D27: dark room. DDC232 board with PD placed face down INSIDE the box.
3 170us 350pC FSR PDs: S12915-16R Saad's office D109: dark room. DDC232 board with PD placed face down INSIDE the box.
4 170us 350pC FSR PDs: S12915-16R Saad's office D109: dark room. DDC232 board with PD placed and covered OUTSIDE the box.
5 170us 350pC FSR PDs: S12915-16R Saad's office D109: dark room. DDC232 board with PD UNPLUGGED placed OUTSIDE the box.
6 170us 350pC FSR PDs: S12915-16R Raffy's office D106: dark room (light off, but blinds open). DDC232 board with PD UNPLUGGED placed OUTSIDE the box.
7 170us 350pC FSR PDs: S12915-16R Raffy's office D106: dark room (blinds closed). DDC232 board with PD UNPLUGGED placed OUTSIDE the box.
8 170us 350pC FSR PDs: S12915-16R Raffy's office D106: dark room (blinds closed). DDC232 board with PD placed and covered OUTSIDE the box.
9 170us 350pC FSR PDs: S12915-16R Raffy's office D106: DDC232 board with PD placed OUTSIDE the box. UV torch.
10 170us 350pC FSR PDs: S12915-16R D109, Dark Measurement, PELI Case (15/12/20).
11 170us 350pC FSR PDs: S12915-16R D27, Dark Measurement, PELI Case (15/12/20).