(Created page with "== Minutes for UCL Proton Calorimetry Meetings, 4th November == === Present === '''Simon Jolly''', '''Raffaella Radogna''', '''Saad Shaikh''', '''Fern Pannell''' === [[ELogs/R...")
 
Line 12: Line 12:
**Can see data coming through – but timing isn't quite right. Need to figure out how to prompt DAQ when data is written into FIFO.
**Can see data coming through – but timing isn't quite right. Need to figure out how to prompt DAQ when data is written into FIFO.
**Need to fix ILA issue when trying to monitor FTDI chip signals.
**Need to fix ILA issue when trying to monitor FTDI chip signals.
*Loading .bit files on Nexys video does not work with USB or SD card. Unsure why this is and Matt Warren had no further suggestions either.
*Will continue testing DDC232 boards with Raffy.
*Will continue testing DDC232 boards with Raffy.


=== [[ELogs/FernPannell|Fern Pannell]] ===
=== [[ELogs/FernPannell|Fern Pannell]] ===

Revision as of 15:15, 11 November 2020

Minutes for UCL Proton Calorimetry Meetings, 4th November

Present

Simon Jolly, Raffaella Radogna, Saad Shaikh, Fern Pannell

Raffaella Radogna

Saad Shaikh

  • Using last couple of switches on Nexys video to select between 4 integration times, which are chosen at compile-time.
  • Continuing work on USB interface using Nexys Video FTDI chip:
    • Can see data coming through – but timing isn't quite right. Need to figure out how to prompt DAQ when data is written into FIFO.
    • Need to fix ILA issue when trying to monitor FTDI chip signals.
  • Loading .bit files on Nexys video does not work with USB or SD card. Unsure why this is and Matt Warren had no further suggestions either.
  • Will continue testing DDC232 boards with Raffy.

Fern Pannell