Proton Calorimetry/Experimental Runs/2020/CrossTalk: Difference between revisions
No edit summary |
No edit summary |
||
Line 1: | Line 1: | ||
14 Feb 2020 | 14 Feb 2020 | ||
cross talk measurements | |||
== cross talk measurements == | |||
Setup: | Setup: |
Revision as of 09:22, 26 August 2020
14 Feb 2020
cross talk measurements
Setup: - scintillator sheets number from bottom to top in sensor image: 9, 8, 22, 26 + other sheet as fillers - CMOS ISDI Image sensor. Sensor was allowed to heat up for an hour before measurements - Optical fibre used with optical gel to couple LED to scintillator sheets Aim: Measure Cross talk between sheets Plan is to insert light into the two middle sheets of the 4 main sheets and measure the light output with the CMOS sensor. Aslo take background images at regular intervals.
data saved in unix/pbt/data/ucl/20200214/
list of runs in this file unix/pbt/data/ucl/20200214/20200214_crosstalk.xlsx