Setup:
- scintillator sheets number from bottom to top in sensor image: 9, 8, 22, 26 + other sheet as fillers
- CMOS ISDI Image sensor. Sensor was allowed to heat up for an hour before measurements
- Optical fibre used with optical gel to couple LED to scintillator sheets
Aim: Measure Cross talk between sheets
Plan is to insert light into the two middle sheets of the 4 main sheets and measure the light output with the CMOS sensor. Aslo take background images at regular intervals.


data saved in unix/pbt/data/ucl/20200214/
data saved in unix/pbt/data/ucl/20200214/


list of runs in this file unix/pbt/data/ucl/20200214/20200214_crosstalk.xlsx
list of runs in this file unix/pbt/data/ucl/20200214/20200214_crosstalk.xlsx

Revision as of 09:22, 26 August 2020

14 Feb 2020

cross talk measurements

Setup: - scintillator sheets number from bottom to top in sensor image: 9, 8, 22, 26 + other sheet as fillers - CMOS ISDI Image sensor. Sensor was allowed to heat up for an hour before measurements - Optical fibre used with optical gel to couple LED to scintillator sheets Aim: Measure Cross talk between sheets Plan is to insert light into the two middle sheets of the 4 main sheets and measure the light output with the CMOS sensor. Aslo take background images at regular intervals.

data saved in unix/pbt/data/ucl/20200214/

list of runs in this file unix/pbt/data/ucl/20200214/20200214_crosstalk.xlsx