Clatterbridge: Difference between revisions

From PBTWiki
Jump to navigation Jump to search
Line 21: Line 21:


== Output files ==
== Output files ==
The simulation code and <code> proton.mac </code> produce several output files:


=== <code> kin.txt </code> ===
=== <code> kin.txt </code> ===

Revision as of 16:11, 26 July 2016

Simulation of the Clatterbridge beamline

This simulation models the monoenergetic 62.5 MeV proton beam at Clatterbridge Cancer Centre, as it traverses the components of the beamline and is then deposited into a volume of water. The beamline components are contained within a geometry modelling the Clatterbridge treatment room.

The protons are generated using the G4ParticleGun class, and the physics list used is QGSP_BIC_HP, standard for simulating clinical proton beams.

The energy of the beam after travelling through the beamline components is measured by tracking the energy deposition of individual protons within the water volume, using the G4Track class. This simulation produces a post-beamline energy of 60.08 MeV and a Bragg peak at depth [insert depth].

[insert image of visualisation]

Running the simulation

Run macro proton.mac

This will run the simulation and produce the required output files.

[username@plus1 ProtonPB_build]$ ./protonPB proton.mac


Output files

The simulation code and proton.mac produce several output files:

kin.txt

This text file contains the output information from SteppingAction.cc , printed on a step-by-step basis for each proton (event). The first column contains the z position of the particle, relative to the position of the source at the inner room boundary. The second column contains the energy (MeV) of the proton at this z position.

300	62.3248
300	62.0776
300	62.2042
300	62.4347
300	62.2698
300	62.2164

Data Analysis

Open ROOT and run analysis file

The simulation analysis file reads the data in the output files and produces the associated plots.

[username@plus1 ProtonPB_build]$ root -l

root [0] .x simulation_analysis.C

Changing parameters

Scoring mesh

Longitudinal scoring mesh

A longitudinal scoring mesh extends along the length of the beamline from the source to the water volume. The mesh utilises a filter to detect the flux of protons per cm2 and writes the data to the text file FluxLongitudinal.txt . The location of the mesh centre can be changed in proton.mac , in addition to the dimensions of the mesh and the number of bins.

Lateral scoring mesh

A lateral scoring mesh is positioned at the end of the nozzle to record the dose distribution of the protons.

Initial beam parameters

Initial parameters of the proton beam can be modified in proton.mac

Beam radius

/gps/pos/radius 3 mm

Beam energy

This simulation models the proton beam source with a Gaussian distribution.

/gps/ene/type Gauss
/gps/ene/mono 62.5 MeV
/gps/ene/sigma 0.082 MeV

Source position

The proton source is positioned at z = -420 cm relative to the centre of the inner room (the mother volume), which translates as the wall surface of the inner room.

/gps/pos/type Plane
/gps/pos/shape Circle
/gps/pos/centre 0.0 0.0 -420 cm


Files