ELogs/JamesGolbourn: Difference between revisions
< ELogs
No edit summary |
|||
Line 2: | Line 2: | ||
== To Do | == To Do == | ||
* Email Alison for details of Hakan Nystrom. | * Email Alison for details of Hakan Nystrom. | ||
Line 14: | Line 14: | ||
* Update presentation with corrections made. | * Update presentation with corrections made. | ||
== Tasks Completed | == Tasks Completed == | ||
* Presentation to PBT group. | * Presentation to PBT group. | ||
Line 21: | Line 21: | ||
* First plan for research essay | * First plan for research essay | ||
== Key Dates | == Key Dates == | ||
{| class="wikitable" | {| class="wikitable" | ||
Line 47: | Line 47: | ||
|} | |} | ||
== Progress Report Outline | == Research Essay First Plan == | ||
* Introduction: | |||
# What is PBT and the theory? | |||
## Different methods of beam production | |||
## Pencil beam scanning and uniform scattering. | |||
# What is Quality Assurance? | |||
## Why is it needed? | |||
## Relation to X-Ray QA and lack of consistency between facilities. | |||
# Beam parameters - what needs to be measured | |||
* Sections on different beam properties and characteristics: | |||
** For each of these sections there should be a description of: | |||
***What is it? | |||
*** Relation to patient dosimetry and why is it important? | |||
*** Methods of measurement. | |||
# Beam energy and range | |||
# Beam output | |||
# Spot size and symmetry | |||
# Spot position and beam uniformity | |||
== Progress Report Outline == | |||
*Introduction to Proton beam therapy. | *Introduction to Proton beam therapy. | ||
Line 54: | Line 78: | ||
*Commercially available devices such as the Matrixx, Lynx and Sun Nuclear QA3. | *Commercially available devices such as the Matrixx, Lynx and Sun Nuclear QA3. | ||
*Other methods for measuring beam properties. | *Other methods for measuring beam properties. | ||
== Comments made about presentation == | |||
== Comments made about presentation | |||
* Understand what range modulators do. | * Understand what range modulators do. | ||
Line 72: | Line 95: | ||
* Collect standards and tolerances on energy, spot size and output. | * Collect standards and tolerances on energy, spot size and output. | ||
== Useful Links for Research Essay | == Useful Links for Research Essay == | ||
* Sun Nuclear QA 3 Device: | * Sun Nuclear QA 3 Device: |
Revision as of 16:24, 4 February 2019
Electronic Log for James Golbourn
To Do
- Email Alison for details of Hakan Nystrom.
- Get in contact with Laurent contact at Med Austrom about QA procedures.
- Plan literature research essay.
- Prepare practice presentation for project (8/2/19)
- Write up report on meeting with UCLH.
- Look at what functioning centres are using as QA.
- Look at advantages and disadvantages of QA systems.
- Write research essay.
- Update presentation with corrections made.
Tasks Completed
- Presentation to PBT group.
- Project progress report.
- Project outline.
- First plan for research essay
Key Dates
Task | Deadline |
---|---|
Project Outline | 03/12/2018 |
Project Progress Report | 31/01/2019 |
Short Presentation | 08/02/2019 |
Research Essay | 31/03/2019 |
Thesis Deadline | 22/08/2019 |
Final Presentation | 02/09/2019 |
Research Essay First Plan
- Introduction:
- What is PBT and the theory?
- Different methods of beam production
- Pencil beam scanning and uniform scattering.
- What is Quality Assurance?
- Why is it needed?
- Relation to X-Ray QA and lack of consistency between facilities.
- Beam parameters - what needs to be measured
- Sections on different beam properties and characteristics:
- For each of these sections there should be a description of:
- What is it?
- Relation to patient dosimetry and why is it important?
- Methods of measurement.
- For each of these sections there should be a description of:
- Beam energy and range
- Beam output
- Spot size and symmetry
- Spot position and beam uniformity
Progress Report Outline
- Introduction to Proton beam therapy.
- What is Quality Assurance?
- Important beam characteristics.
- Commercially available devices such as the Matrixx, Lynx and Sun Nuclear QA3.
- Other methods for measuring beam properties.
Comments made about presentation
- Understand what range modulators do.
- Look into whether Zebra was initially designed for X-Rays.
- Zebra not often used for daily QA due to the very long initial set up time.
- Investigate film dosimetry e.g Gafchromic film.
- Research Lynx scintillator.
- Range calorimeter - need a moving absorber, e.g water tank, to measure energy and range.
- Know difference between scintillator screens and fibres - fibres use fibre optics and are not used due to needing something to read output from each fibre which is expensive.
- UCLH will have 4 treatment rooms.
- Put slide number on presentation.
- Expand on each daily QA:
- Table of devices
- Tolerances
- How long it takes
- Collect standards and tolerances on energy, spot size and output.
Useful Links for Research Essay
- Sun Nuclear QA 3 Device:
- A novel daily QA system for proton therapy
- Daily QA in proton therapy using a single commercially available detector
- Sun Nuclear QA 3 Fact Sheet
- Technical Note: An efficient daily QA procedure for proton pencil beam scanning
- IBA Zebra:
- Quality assurance of proton beams using a multilayer ionization chamber system