Line 22: |
Line 22: |
| == Key Dates: == | | == Key Dates: == |
|
| |
|
| * Project Outline - 03/12/2018
| | {| class="wikitable" |
| * Project Progress Report - 31/01/2019
| | |- |
| * Short Presentation - 08/02/2019 (9.00 am)
| | ! Task |
| * Research Essay - 31/03/2019
| | ! Deadline |
| * Thesis Deadline - 22/08/2019
| | |- |
| * Final Presentation - 02/09/2019
| | | Project Outline |
| | | 03/12/2018 |
| | |- |
| | | Project Progress Report |
| | | 31/01/2019 |
| | |- |
| | | Short Presentation |
| | | 08/02/2019 |
| | |- |
| | | Research Essay |
| | | 31/03/2019 |
| | |- |
| | | Thesis Deadline |
| | | 22/08/2019 |
| | |- |
| | | Final Presentation |
| | | 02/09/2019 |
|
| |
|
| == Progress Report Outline: == | | == Progress Report Outline: == |
Revision as of 17:56, 2 February 2019
Electronic Log for James Golbourn
To Do:
- Email Alison for details of Hakan Nystrom.
- Get in contact with Laurent contact at Med Austrom about QA procedures.
- Plan literature research essay.
- Prepare practice presentation for project (8/2/19)
- Write up report on meeting with UCLH.
- Look at what functioning centres are using as QA.
- Look at advantages and disadvantages of QA systems.
- Write research essay.
- Update presentation with corrections made.
Tasks Completed:
- Presentation to PBT group.
- Project progress report.
- Project outline.
Key Dates:
Task
|
Deadline
|
Project Outline
|
03/12/2018
|
Project Progress Report
|
31/01/2019
|
Short Presentation
|
08/02/2019
|
Research Essay
|
31/03/2019
|
Thesis Deadline
|
22/08/2019
|
Final Presentation
|
02/09/2019
Progress Report Outline:
- Introduction to Proton beam therapy.
- What is Quality Assurance?
- Important beam characteristics.
- Commercially available devices such as the Matrixx, Lynx and Sun Nuclear QA3.
- Other methods for measuring beam properties.
- Understand what range modulators do.
- Look into whether Zebra was initially designed for X-Rays.
- Zebra not often used for daily QA due to the very long initial set up time.
- Investigate film dosimetry e.g Gafchromic film.
- Research Lynx scintillator.
- Range calorimeter - need a moving absorber, e.g water tank, to measure energy and range.
- Know difference between scintillator screens and fibres - fibres use fibre optics and are not used due to needing something to read output from each fibre which is expensive.
- UCLH will have 4 treatment rooms.
- Put slide number on presentation.
- Expand on each daily QA:
- Table of devices
- Tolerances
- How long it takes
- Collect standards and tolerances on energy, spot size and output.
Useful Links for Research Essay:
- Sun Nuclear QA 3 Device:
- A novel daily QA system for proton therapy
- Daily QA in proton therapy using a single commercially available detector
- Sun Nuclear QA 3 Fact Sheet
- Technical Note: An efficient daily QA procedure for proton pencil beam scanning
- IBA Zebra:
- Quality assurance of proton beams using a multilayer ionization chamber system
|