Proton Calorimetry/Experimental Runs/2018/Feb21: Difference between revisions
(→Equipment List: Added first-pass account of equipment) |
|||
| Line 14: | Line 14: | ||
|- | |- | ||
| style="text-align: center;" | Portable Enclosure | | style="text-align: center;" | Portable Enclosure | ||
| style="text-align: center;" | Modified Peli 1510 Waterproof Wheeled Equipment Case. | | style="text-align: center;" | Modified Peli 1510 Waterproof Wheeled Equipment Case. <br/> | ||
230 x 555 x 350mm | 230 x 555 x 350mm <br/> | ||
Features mount for scintillator and PMT, beam | Features mount for scintillator and PMT, opening for beam, and ports for SHV, BNC, and SMA cables. <br/> | ||
Requires a | Requires a window (paper? Mylar? tape?) to ensure the opening for the beam is light-tight. | ||
|- | |- | ||
| style="text-align: center;" | LeCroy HDO6104 Oscilloscope | | style="text-align: center;" | LeCroy HDO6104 Oscilloscope | ||
Revision as of 19:04, 16 February 2018
Beam tests of the single module with PRaVDA CMOS pixel sensors (PRIAPUS) at the Birmingham Cyclotron with a 36 MeV beam.
Equipment List
| Item | Notes |
|---|---|
| Single Module Scintillator Block | Optical grease required to couple Scintillator to PMT |
| Photomultiplier Tube | (Hamamatsu 2"?) |
| Portable Enclosure | Modified Peli 1510 Waterproof Wheeled Equipment Case. 230 x 555 x 350mm |
| LeCroy HDO6104 Oscilloscope | Requires a power supply. |
| DAQ Laptop | Requires a power supply. (Connected to enclosure how? Or to LeCroy HDO6104? Requires USB?) |
| Control Laptop x 2 | One each for Remote Desktop control of LeCroy Oscilloscope and DAQ Laptop. Require power supplies. |
| Linksys EA6900 Network Hub x 2 | One for the experimental room for the LeCroy HDO6104 and DAQ Laptop to connect to,
one for the control room for each of the Control Laptops to connect to. |
| Ethernet Cable (Long) | To connect the two Network Hubs and complete the network for controlling DAQ equipment from the control room. |
| BNC to SMA Cable (Short) | Signal from PMT to enclosure port |
| SMA to BNC Cable (Long) | Signal from enclosure port to LeCroy Oscilloscope |
| SHV Cable (Short) | HV supply from enclosure port to PMT |
| SHV Cable (Long) | HV supply from experimental room to enclosure port |