Proton Calorimetry/Experimental Runs/2022/UCLHWET: Difference between revisions
SaadShaikh (talk | contribs) (Created page with "== Experiment Plan == *WET measurement of stack of clear sheets with mylar foil. *Addition of stack of white painted sheets for WET measurement of both stacks. *Removal of stack ...") |
SaadShaikh (talk | contribs) No edit summary |
||
Line 1: | Line 1: | ||
== Detector Equipment == | |||
*C-section stack holder containing 25 clear scintillator sheets around 2.86 mm thick with 24 sheets of mylar foil. '''Add 25th sheet of Mylar?''' | |||
*C-section stack holder containing 23 white painted scintillator sheets around 2.86 mm thick. | |||
*Zarges case. | |||
== Experiment Plan == | == Experiment Plan == | ||
*WET measurement of stack of clear sheets with mylar foil. | *WET measurement of stack of clear sheets with mylar foil. |
Revision as of 10:08, 8 August 2022
Detector Equipment
- C-section stack holder containing 25 clear scintillator sheets around 2.86 mm thick with 24 sheets of mylar foil. Add 25th sheet of Mylar?
- C-section stack holder containing 23 white painted scintillator sheets around 2.86 mm thick.
- Zarges case.
Experiment Plan
- WET measurement of stack of clear sheets with mylar foil.
- Addition of stack of white painted sheets for WET measurement of both stacks.
- Removal of stack of clear sheets for WET measurement of stack of white painted sheets.
- WET measurement of Zarges case with mylar windows without any stacks of scintillator?