Proton Calorimetry/Meetings/2021/12/09: Difference between revisions
SaadShaikh (talk | contribs) (Created page with "== Minutes for UCL Proton Calorimetry Meetings, 9th December == === Present === '''Simon Jolly''', '''Saad Shaikh''' === Saad Shaikh === *Consolidated UCL...") |
SaadShaikh (talk | contribs) No edit summary |
||
Line 6: | Line 6: | ||
=== [[ELogs/SaadShaikh|Saad Shaikh]] === | === [[ELogs/SaadShaikh|Saad Shaikh]] === | ||
*Consolidated UCLH analysis with latest (corrected) plots into two presentations: 15th April experiment and 2nd Nov experiment. | *Consolidated UCLH analysis with latest (corrected) plots into two presentations: [http://www.hep.ucl.ac.uk/pbt/wikiData/presentations/2021/SS210428_UCLH.pptx 15th April experiment] and [http://www.hep.ucl.ac.uk/pbt/wikiData/presentations/2021/SS211110_UCLH.pptx 2nd Nov experiment]. | ||
**Will update links to these in previous meeting minutes etc. | **Will update links to these in previous meeting minutes etc. | ||
**Correcting PDL normalisation in comparisons found that photodiodes match up very well with CMOS sensor in April experiment. | **Correcting PDL normalisation in comparisons found that photodiodes match up very well with CMOS sensor in April experiment. | ||
Line 15: | Line 15: | ||
*Literature value of Birks' constant summarised in table 2.2 of Laurent's thesis – values vary greatly and are very specific to material itself. | *Literature value of Birks' constant summarised in table 2.2 of Laurent's thesis – values vary greatly and are very specific to material itself. | ||
**Will perform fits to Nikon data to see if Birks' value is consistent. | **Will perform fits to Nikon data to see if Birks' value is consistent. | ||
*Delivered presentation at FRPT 2021, slides available here. | *Delivered presentation at FRPT 2021, slides available [http://www.hep.ucl.ac.uk/pbt/wikiData/presentations/2021/SS211203_FRPT.pptx here]. | ||
*Naoki presented first results with hardware implementation of fitting function, slides available here. | *Naoki presented first results with hardware implementation of fitting function, slides available here. | ||
**Will download and test software version of code that performs fit without ROOT. | **Will download and test software version of code that performs fit without ROOT. | ||
*Will deliver Christmas Talk on 20th December for HEP Group Day. | *Will deliver Christmas Talk on 20th December for HEP Group Day. |
Revision as of 17:33, 9 December 2021
Minutes for UCL Proton Calorimetry Meetings, 9th December
Present
Simon Jolly, Saad Shaikh
Saad Shaikh
- Consolidated UCLH analysis with latest (corrected) plots into two presentations: 15th April experiment and 2nd Nov experiment.
- Will update links to these in previous meeting minutes etc.
- Correcting PDL normalisation in comparisons found that photodiodes match up very well with CMOS sensor in April experiment.
- Coupled with no change in fit results with CMOS sensor photodiode approximation fits, photodiodes appear to see enough light to give good results.
- Ran fit replays for all runs in April and November experiments.
- In November experiment, only Run 16 gave unphysical results, likely due to low light levels.
- Will investigate if parameter limits can fix this.
- Literature value of Birks' constant summarised in table 2.2 of Laurent's thesis – values vary greatly and are very specific to material itself.
- Will perform fits to Nikon data to see if Birks' value is consistent.
- Delivered presentation at FRPT 2021, slides available here.
- Naoki presented first results with hardware implementation of fitting function, slides available here.
- Will download and test software version of code that performs fit without ROOT.
- Will deliver Christmas Talk on 20th December for HEP Group Day.