Proton Calorimetry/Meetings/2019/11/12: Difference between revisions
No edit summary |
No edit summary |
||
Line 15: | Line 15: | ||
=== [[ELogs/LaurentKelleter|Laurent Kelleter]] === | === [[ELogs/LaurentKelleter|Laurent Kelleter]] === | ||
* presents results about range uncertainties of the QuARC | * presents results about range uncertainties of the QuARC [http://www.hep.ucl.ac.uk/pbt/wikiData/presentations/2019/LK20191107_RangeUncertainties.odp slides] | ||
** uncertainty from the fit of light-depth curve is about 50um, but there are other sources of systematic uncertainty | ** uncertainty from the fit of light-depth curve is about 50um, but there are other sources of systematic uncertainty | ||
* all the systematics discussed will be included in the QuARC paper and the thesis | * all the systematics discussed will be included in the QuARC paper and the thesis | ||
Line 23: | Line 23: | ||
* worked on setup. New way of coupling PD to the scintillator stack | * worked on setup. New way of coupling PD to the scintillator stack | ||
* run an experiment injecting light to a sheet at the time to check the cross talk | * run an experiment injecting light to a sheet at the time to check the cross talk | ||
* will analyse data | |||
=== [[ELogs/SimonJolly|Simon Jolly]] === | === [[ELogs/SimonJolly|Simon Jolly]] === | ||
* meeting with Cham on Friday this week | * meeting with Cham on Friday this week | ||
Revision as of 17:49, 12 November 2019
Minutes for UCL Proton Calorimetry Meetings, 12th November 2019 (D17, Physics & Astronomy, UCL)
Present
Simon Jolly, Laurent Kelleter, Raffaella Radogna, Saad Shaikh
Saad Shaikh
- progress on fitting Bortfeld's Bragg curve on simulation data from Geant4 (from Laurent)
- the code is ported in Eclipse and now is cpp executable, but still uses ROOT
- next step will be the quenched Bragg curve and real data analysis
- he will also start running the CMOS sensor and collect instructions about
- running the software and acquiring images
- analysing images
- new directory pbt/wikiData/teaching
Laurent Kelleter
- presents results about range uncertainties of the QuARC slides
- uncertainty from the fit of light-depth curve is about 50um, but there are other sources of systematic uncertainty
- all the systematics discussed will be included in the QuARC paper and the thesis
- the paper about mixed beam has been reviewed with positive outcome. Lenny and Laurent will answer.
Raffaella Radogna
- worked on setup. New way of coupling PD to the scintillator stack
- run an experiment injecting light to a sheet at the time to check the cross talk
- will analyse data
Simon Jolly
- meeting with Cham on Friday this week