Proton Calorimetry/Experimental Runs/2018/Nov16-18: Difference between revisions
Line 30: | Line 30: | ||
|} | |} | ||
Range Detector Experiment | ==== Range Detector Experiment ==== | ||
{| class="wikitable" | {| class="wikitable" | ||
! style="text-align: center;" | Item | ! style="text-align: center;" | Item | ||
Line 36: | Line 36: | ||
|- | |- | ||
|} | |} | ||
Single Module Experiment | ==== Single Module Experiment ==== | ||
{| class="wikitable" | {| class="wikitable" | ||
! style="text-align: center;" | Item | ! style="text-align: center;" | Item |
Revision as of 02:20, 12 November 2018
2 night shifts with range calorimeter and single PMT module.
Equipment List
Item | Notes |
---|---|
Portable Enclosure | Modified Zarges 1510 Waterproof Wheeled Equipment Case. 230 x 555 x 350mm |
DAQ desktop PC | |
Control Laptop | |
Ethernet Switcher | Set in experiment room and connected DAQ desktop PC. Output sent to control room Network Hub. |
Network Hub | Set in control room to take output from ethernet switcher. Control laptops connected via ethernet or 5GHz WiFi. |
Ethernet Cable x 2 | To connect DAQ PC to switcher, switcher to Network Hub. |
Range Detector Experiment
Item | Notes |
---|
Single Module Experiment
Item | Notes |
---|---|
Single Module Scintillator Blocks x5 | 1cm/3cm/5cm x 10cm x 10cm standard scintillator block. Optical gel required to couple Scintillator to PMT. 5cm and 3cm with black wrapping. 5cm, 3cm, 1cm mylar wrapping. |
Photomultiplier Tube | Hamamatsu R13089 2" |
Portable Enclosure | Modified Zarges 1510 Waterproof Wheeled Equipment Case. 230 x 555 x 350mm |
Caen DT5751 Digitiser | Records PMT output, connected via SMA-MCX conversion. Used channel 3. |
DAQ desktop PC | Controls Caen HV supply; records data from Caen digitiser. |
Caen NDT1470 HV Supply | Supplies HV to PMT |
USB Cable | Caen units to DAQ PC |
Male-to-Male SMA Cable x2 | Signal from enclosure port to digitiser. Short/Light and Long cables connected trough SMA to SMA connector |
Female-to-Female SMA Connector | Connects Long SMA cable to Short/Light SMA cable. |
Male SMA to Male MCX Adaptor | Sends output from SMA cable to Digitiser |
Gloves | For handling scintillator |
Optical gel | For coupling scintillator to PMT |
Wipes | For removing optical gel |
Experiment List
16–17th November
ISDI sensor + scintillator stack
17–18th November
Single module
Experiment Log
Beam Tests
16–17th November
Run Number | High Voltage (V) | Trigger Level (mV) | Trigger Source | Beam Current / Rate | Collimator | Filename | Notes |
---|---|---|---|---|---|---|---|
00 | -900 | 70, +ve | Tracker (C2) | 170pA/~10 kHz | 2 mm centred | run00_2mmCCol_160pA_TrackTrig | First test of tracker/PMT synchronisation |