Proton Calorimetry/Experimental Runs/2018/Nov16-18: Difference between revisions
SimonJolly (talk | contribs) No edit summary |
|||
| Line 7: | Line 7: | ||
! style="text-align: center;" | Notes | ! style="text-align: center;" | Notes | ||
|- | |- | ||
| style="text-align: center;" | Single Module Scintillator | | style="text-align: center;" | Portable Enclosure | ||
| style="text-align: center;" | 3cm x | | style="text-align: center;" | Modified Zarges 1510 Waterproof Wheeled Equipment Case. <br/> | ||
230 x 555 x 350mm <br/> | |||
Features mount for scintillator and PMT, opening for beam, and ports for SHV, BNC, and SMA cables. <br/> | |||
Mylar window with Al support mounted to internal face: approximately light-tight. <br/> | |||
BNC output from case connected to SMA splitter. | |||
|- | |||
| style="text-align: center;" | DAQ desktop PC | |||
| style="text-align: center;" | | |||
|- | |||
| style="text-align: center;" | Control Laptop | |||
| style="text-align: center;" | | |||
|- | |||
| style="text-align: center;" | Ethernet Switcher | |||
| style="text-align: center;" | Set in experiment room and connected DAQ desktop PC. Output sent to control room Network Hub. | |||
|- | |||
| style="text-align: center;" | Network Hub | |||
| style="text-align: center;" | Set in control room to take output from ethernet switcher. Control laptops connected via ethernet or 5GHz WiFi. | |||
|- | |||
| style="text-align: center;" | Ethernet Cable x 2 | |||
| style="text-align: center;" | To connect DAQ PC to switcher, switcher to Network Hub. | |||
|} | |||
Single Module Experiment | |||
{| class="wikitable" | |||
! style="text-align: center;" | Item | |||
! style="text-align: center;" | Notes | |||
|- | |||
| style="text-align: center;" | Single Module Scintillator Blocks x5 | |||
| style="text-align: center;" | 1cm/3cm/5cm x 10cm x 10cm standard scintillator block. Optical gel required to couple Scintillator to PMT. 5cm and 3cm with black wrapping. 5cm, 3cm, 1cm mylar wrapping. | |||
|- | |- | ||
| style="text-align: center;" | Photomultiplier Tube | | style="text-align: center;" | Photomultiplier Tube | ||
| Line 14: | Line 42: | ||
|- | |- | ||
| style="text-align: center;" | Portable Enclosure | | style="text-align: center;" | Portable Enclosure | ||
| style="text-align: center;" | Modified | | style="text-align: center;" | Modified Zarges 1510 Waterproof Wheeled Equipment Case. <br/> | ||
230 x 555 x 350mm <br/> | 230 x 555 x 350mm <br/> | ||
Features mount for scintillator and PMT, opening for beam, and ports for SHV, BNC, and SMA cables. <br/> | Features mount for scintillator and PMT, opening for beam, and ports for SHV, BNC, and SMA cables. <br/> | ||
Mylar window with Al support mounted to internal face: approximately light-tight. <br/> | Mylar window with Al support mounted to internal face: approximately light-tight. <br/> | ||
BNC output from case connected to SMA splitter. | BNC output from case connected to SMA splitter. | ||
|- | |- | ||
| style="text-align: center;" | Caen DT5751 Digitiser | | style="text-align: center;" | Caen DT5751 Digitiser | ||
| style="text-align: center;" | Records PMT output, connected via SMA-MCX conversion. Used channel 3. | | style="text-align: center;" | Records PMT output, connected via SMA-MCX conversion. Used channel 3. | ||
|- | |- | ||
| style="text-align: center;" | DAQ | | style="text-align: center;" | DAQ desktop PC | ||
| style="text-align: center;" | Controls Caen HV supply; records data from Caen digitiser. | | style="text-align: center;" | Controls Caen HV supply; records data from Caen digitiser. | ||
|- | |- | ||
| Line 32: | Line 57: | ||
| style="text-align: center;" | Supplies HV to PMT | | style="text-align: center;" | Supplies HV to PMT | ||
|- | |- | ||
| style="text-align: center;" | | | style="text-align: center;" | USB Cable | ||
| style="text-align: center;" | | | style="text-align: center;" | Caen units to DAQ PC | ||
|- | |- | ||
| style="text-align: center;" | | | style="text-align: center;" | Male-to-Male SMA Cable x2 | ||
| style="text-align: center;" | | | style="text-align: center;" | Signal from enclosure port to digitiser. Short/Light and Long cables connected trough SMA to SMA connector | ||
|- | |- | ||
| style="text-align: center;" | | | style="text-align: center;" | Female-to-Female SMA Connector | ||
| style="text-align: center;" | | | style="text-align: center;" | Connects Long SMA cable to Short/Light SMA cable. | ||
|- | |- | ||
| style="text-align: center;" | | | style="text-align: center;" | Male SMA to Male MCX Adaptor | ||
| style="text-align: center;" | Sends output from SMA cable to Digitiser | |||
| style="text-align: center;" | Sends | |||
|- | |- | ||
| style="text-align: center;" | Gloves | | style="text-align: center;" | Gloves | ||
Revision as of 02:12, 12 November 2018
2 night shifts with range calorimeter and single PMT module.
Equipment List
| Item | Notes |
|---|---|
| Portable Enclosure | Modified Zarges 1510 Waterproof Wheeled Equipment Case. 230 x 555 x 350mm |
| DAQ desktop PC | |
| Control Laptop | |
| Ethernet Switcher | Set in experiment room and connected DAQ desktop PC. Output sent to control room Network Hub. |
| Network Hub | Set in control room to take output from ethernet switcher. Control laptops connected via ethernet or 5GHz WiFi. |
| Ethernet Cable x 2 | To connect DAQ PC to switcher, switcher to Network Hub. |
Single Module Experiment
| Item | Notes |
|---|---|
| Single Module Scintillator Blocks x5 | 1cm/3cm/5cm x 10cm x 10cm standard scintillator block. Optical gel required to couple Scintillator to PMT. 5cm and 3cm with black wrapping. 5cm, 3cm, 1cm mylar wrapping. |
| Photomultiplier Tube | Hamamatsu R13089 2" |
| Portable Enclosure | Modified Zarges 1510 Waterproof Wheeled Equipment Case. 230 x 555 x 350mm |
| Caen DT5751 Digitiser | Records PMT output, connected via SMA-MCX conversion. Used channel 3. |
| DAQ desktop PC | Controls Caen HV supply; records data from Caen digitiser. |
| Caen NDT1470 HV Supply | Supplies HV to PMT |
| USB Cable | Caen units to DAQ PC |
| Male-to-Male SMA Cable x2 | Signal from enclosure port to digitiser. Short/Light and Long cables connected trough SMA to SMA connector |
| Female-to-Female SMA Connector | Connects Long SMA cable to Short/Light SMA cable. |
| Male SMA to Male MCX Adaptor | Sends output from SMA cable to Digitiser |
| Gloves | For handling scintillator |
| Optical gel | For coupling scintillator to PMT |
| Wipes | For removing optical gel |
Experiment List
16–17th November
ISDI sensor + scintillator stack
17–18th November
Single module
Experiment Log
Beam Tests
16–17th November
| Run Number | High Voltage (V) | Trigger Level (mV) | Trigger Source | Beam Current / Rate | Collimator | Filename | Notes |
|---|---|---|---|---|---|---|---|
| 00 | -900 | 70, +ve | Tracker (C2) | 170pA/~10 kHz | 2 mm centred | run00_2mmCCol_160pA_TrackTrig | First test of tracker/PMT synchronisation |