Proton Calorimetry/Experimental Runs/2018/Nov16-18: Difference between revisions

From PBTWiki
Jump to navigation Jump to search
No edit summary
Line 7: Line 7:
! style="text-align: center;" | Notes
! style="text-align: center;" | Notes
|-
|-
| style="text-align: center;" | Single Module Scintillator Block
| style="text-align: center;" | Portable Enclosure
| style="text-align: center;" | 3cm x 3cm x 5cm standard scintillator block. Optical gel required to couple Scintillator to PMT
| style="text-align: center;" | Modified Zarges 1510 Waterproof Wheeled Equipment Case. <br/>
230 x 555 x 350mm <br/>
Features mount for scintillator and PMT, opening for beam, and ports for SHV, BNC, and SMA cables. <br/>
Mylar window with Al support mounted to internal face: approximately light-tight. <br/>
BNC output from case connected to SMA splitter.
|-
| style="text-align: center;" | DAQ desktop PC
| style="text-align: center;" |
|-
| style="text-align: center;" | Control Laptop
| style="text-align: center;" |
|-
| style="text-align: center;" | Ethernet Switcher
| style="text-align: center;" | Set in experiment room and connected DAQ desktop PC. Output sent to control room Network Hub.
|-
| style="text-align: center;" | Network Hub
| style="text-align: center;" | Set in control room to take output from ethernet switcher. Control laptops connected via ethernet or 5GHz WiFi.
|-
| style="text-align: center;" | Ethernet Cable x 2
| style="text-align: center;" | To connect DAQ PC to switcher, switcher to Network Hub.
|}
 
Single Module Experiment
{| class="wikitable"
! style="text-align: center;" | Item
! style="text-align: center;" | Notes
|-
| style="text-align: center;" | Single Module Scintillator Blocks x5
| style="text-align: center;" | 1cm/3cm/5cm x 10cm x 10cm standard scintillator block. Optical gel required to couple Scintillator to PMT. 5cm and 3cm with black wrapping. 5cm, 3cm, 1cm mylar wrapping.
|-
|-
| style="text-align: center;" | Photomultiplier Tube
| style="text-align: center;" | Photomultiplier Tube
Line 14: Line 42:
|-
|-
| style="text-align: center;" | Portable Enclosure
| style="text-align: center;" | Portable Enclosure
| style="text-align: center;" | Modified Peli 1510 Waterproof Wheeled Equipment Case. <br/>
| style="text-align: center;" | Modified Zarges 1510 Waterproof Wheeled Equipment Case. <br/>
230 x 555 x 350mm <br/>
230 x 555 x 350mm <br/>
Features mount for scintillator and PMT, opening for beam, and ports for SHV, BNC, and SMA cables. <br/>
Features mount for scintillator and PMT, opening for beam, and ports for SHV, BNC, and SMA cables. <br/>
Mylar window with Al support mounted to internal face: approximately light-tight. <br/>
Mylar window with Al support mounted to internal face: approximately light-tight. <br/>
BNC output from case connected to SMA splitter.
BNC output from case connected to SMA splitter.
|-
| style="text-align: center;" | LeCroy HDO6104 Oscilloscope
| style="text-align: center;" | Records PMT output, connected via SMA-BNC conversion.
|-
|-
| style="text-align: center;" | Caen DT5751 Digitiser
| style="text-align: center;" | Caen DT5751 Digitiser
| style="text-align: center;" | Records PMT output, connected via SMA-MCX conversion. Used channel 3.
| style="text-align: center;" | Records PMT output, connected via SMA-MCX conversion. Used channel 3.
|-
|-
| style="text-align: center;" | DAQ Laptop
| style="text-align: center;" | DAQ desktop PC
| style="text-align: center;" | Controls Caen HV supply; records data from Caen digitiser.
| style="text-align: center;" | Controls Caen HV supply; records data from Caen digitiser.
|-
|-
Line 32: Line 57:
| style="text-align: center;" | Supplies HV to PMT
| style="text-align: center;" | Supplies HV to PMT
|-
|-
| style="text-align: center;" | PRaVDA Strip Tracker
| style="text-align: center;" | USB Cable
| style="text-align: center;" | PRaVDA Unit A, 3x150um Si strip sensors with 90.4um strip pitch. <br/> Firmware version update to yield square pulse out when 2 or 3 layers have a strip over threshold per read out cycle
| style="text-align: center;" | Caen units to DAQ PC
|-
|-
| style="text-align: center;" | Control Laptop x 3
| style="text-align: center;" | Male-to-Male SMA Cable x2
| style="text-align: center;" | Two used for Remote Desktop control of LeCroy Oscilloscope and DAQ Laptop. Third used for taking down notes.
| style="text-align: center;" | Signal from enclosure port to digitiser. Short/Light and Long cables connected trough SMA to SMA connector
|-
|-
| style="text-align: center;" | Ethernet Switcher
| style="text-align: center;" | Female-to-Female SMA Connector
| style="text-align: center;" | Set in experiment room and connected LeCroy Oscilloscope and DAQ laptop. Output sent to control room Network Hub.
| style="text-align: center;" | Connects Long SMA cable to Short/Light SMA cable.
|-
|-
| style="text-align: center;" | Network Hub
| style="text-align: center;" | Male SMA to Male MCX Adaptor
| style="text-align: center;" | Set in control room to take output from ethernet switcher. Control laptops connected via ethernet or 5GHz WiFi.
| style="text-align: center;" | Sends output from SMA cable to Digitiser
|-
| style="text-align: center;" | Ethernet Cable x 3
| style="text-align: center;" | To connect 1 control laptop, the LeCroy HDO6104 and DAQ Laptop to their respective network hubs.
|-
| style="text-align: center;" | Ethernet Cable
| style="text-align: center;" | To connect control Network Hub to Ethernet Switcher.
|-
| style="text-align: center;" | Male-to-Male SMA Cable
| style="text-align: center;" | Signal from enclosure port to Splitter
|-
| style="text-align: center;" | DC-4200 MHz Signal Splitter
| style="text-align: center;" | Splits SMA signal to two SMA signals – sent to Oscilloscope and Digitiser.
|-
| style="text-align: center;" | Male SMA to Male BNC cable
| style="text-align: center;" | Sends 1 output from splitter to Oscilloscope.
|-
| style="text-align: center;" | Male SMA to Male MCX cable
| style="text-align: center;" | Sends 1 output from splitter to Digitiser
|-
| style="text-align: center;" | USB Cable
| style="text-align: center;" | Caen HV unit to DAQ Laptop
|-
|-
| style="text-align: center;" | Gloves
| style="text-align: center;" | Gloves

Revision as of 02:12, 12 November 2018

2 night shifts with range calorimeter and single PMT module.

Equipment List

Item Notes
Portable Enclosure Modified Zarges 1510 Waterproof Wheeled Equipment Case.

230 x 555 x 350mm
Features mount for scintillator and PMT, opening for beam, and ports for SHV, BNC, and SMA cables.
Mylar window with Al support mounted to internal face: approximately light-tight.
BNC output from case connected to SMA splitter.

DAQ desktop PC
Control Laptop
Ethernet Switcher Set in experiment room and connected DAQ desktop PC. Output sent to control room Network Hub.
Network Hub Set in control room to take output from ethernet switcher. Control laptops connected via ethernet or 5GHz WiFi.
Ethernet Cable x 2 To connect DAQ PC to switcher, switcher to Network Hub.

Single Module Experiment

Item Notes
Single Module Scintillator Blocks x5 1cm/3cm/5cm x 10cm x 10cm standard scintillator block. Optical gel required to couple Scintillator to PMT. 5cm and 3cm with black wrapping. 5cm, 3cm, 1cm mylar wrapping.
Photomultiplier Tube Hamamatsu R13089 2"
Portable Enclosure Modified Zarges 1510 Waterproof Wheeled Equipment Case.

230 x 555 x 350mm
Features mount for scintillator and PMT, opening for beam, and ports for SHV, BNC, and SMA cables.
Mylar window with Al support mounted to internal face: approximately light-tight.
BNC output from case connected to SMA splitter.

Caen DT5751 Digitiser Records PMT output, connected via SMA-MCX conversion. Used channel 3.
DAQ desktop PC Controls Caen HV supply; records data from Caen digitiser.
Caen NDT1470 HV Supply Supplies HV to PMT
USB Cable Caen units to DAQ PC
Male-to-Male SMA Cable x2 Signal from enclosure port to digitiser. Short/Light and Long cables connected trough SMA to SMA connector
Female-to-Female SMA Connector Connects Long SMA cable to Short/Light SMA cable.
Male SMA to Male MCX Adaptor Sends output from SMA cable to Digitiser
Gloves For handling scintillator
Optical gel For coupling scintillator to PMT
Wipes For removing optical gel

Experiment List

16–17th November

ISDI sensor + scintillator stack

17–18th November

Single module

Experiment Log

Beam Tests

16–17th November

Run Number High Voltage (V) Trigger Level (mV) Trigger Source Beam Current / Rate Collimator Filename Notes
00 -900 70, +ve Tracker (C2) 170pA/~10 kHz 2 mm centred run00_2mmCCol_160pA_TrackTrig First test of tracker/PMT synchronisation