Proton Calorimetry/Meetings/2018/11/07: Difference between revisions
SimonJolly (talk | contribs) No edit summary |
SimonJolly (talk | contribs) No edit summary |
||
Line 16: | Line 16: | ||
** Background reading! | ** Background reading! | ||
''' | '''MH''': | ||
* | * Pure Geant4 pCT simulation matches results from GATE. | ||
* | |||
Multithreaded simulations result in multiple data files: | |||
** Geant4 cannot merge them itself. | ** Geant4 cannot merge them itself. | ||
** Possible to merge manually. | ** Possible to merge manually. | ||
Line 34: | Line 27: | ||
** Build application for Legion cluster: need to speak to Research Computing. | ** Build application for Legion cluster: need to speak to Research Computing. | ||
** Test application on HEP and Legion clusters. | ** Test application on HEP and Legion clusters. | ||
'''SS''': | |||
* Looking through data from [[Proton_Calorimetry/Experimental_Runs/2018/Oct25-6|Birmingham experimental runs]]. | |||
* Results generally look good: | |||
** Clear double peak for eyepatch data. | |||
** Some spectra show unexpected double peaks: '''SJ''' suggests PMT rate effects. | |||
* '''To Do''': | |||
** Analyse scope data by Christmas. | |||
** Take data for LeCroy scope trigger rate test. | |||
'''FFF''': | '''FFF''': | ||
Line 42: | Line 44: | ||
** Front end electronics design and readout. | ** Front end electronics design and readout. | ||
* Will contact '''Ruben Saakyan''' to discuss options and find out more about light detection options. | * Will contact '''Ruben Saakyan''' to discuss options and find out more about light detection options. | ||
'''LK''': | '''LK''': |
Revision as of 15:12, 7 November 2018
Minutes for UCL Proton Calorimetry Meeting, 7th November 2018 (D17, Physics & Astronomy, UCL)
Present
Simon Jolly, Matthieu Hentz, Laurent Kelleter, Jeremy Ocampo, Saad Shaikh, Fernando Franco Felix, Ohie Mayenin
JO:
- Attending HEP lectures: HEP Monday and Tuesday, CDT Thursday.
- Going through Geant4 simulations: cannot view graphics on Windows laptop...
- Laptop has been ordered by SJ and Tony Hoare.
- Met with Jamie McClelland and Adam Gibson on 18th October: have been provided with reading list.
- Will take Medical Physics/CDT courses next term: Numerical Optimisation and Inverse Problems.
- To Do:
- Try analysing Geant4 simulation results in Python.
- Background reading!
MH:
- Pure Geant4 pCT simulation matches results from GATE.
Multithreaded simulations result in multiple data files:
- Geant4 cannot merge them itself.
- Possible to merge manually.
- RR suggests that merging should work automatically: will investigate.
- To Do:
- Build application for Legion cluster: need to speak to Research Computing.
- Test application on HEP and Legion clusters.
SS:
- Looking through data from Birmingham experimental runs.
- Results generally look good:
- Clear double peak for eyepatch data.
- Some spectra show unexpected double peaks: SJ suggests PMT rate effects.
- To Do:
- Analyse scope data by Christmas.
- Take data for LeCroy scope trigger rate test.
FFF:
- Background reading on proton therapy: LK recommended Paganetti: Proton Therapy Physics.
- Met with LK to discuss detector development.
- Two potential ideas for Masters project:
- Complete range calorimeter simulations.
- Front end electronics design and readout.
- Will contact Ruben Saakyan to discuss options and find out more about light detection options.
LK:
- Working on build-up simulation paper: need to check LET definition.
- Debugging Geant4 simulations with CentOS 7 environment.
- Organisation of HIT trip.