Proton Calorimetry/Experimental Runs/2018/Oct25-6: Difference between revisions
SaadShaikh (talk | contribs) m (→Equipment List) |
SaadShaikh (talk | contribs) |
||
Line 23: | Line 23: | ||
| style="text-align: center;" | Records PMT output, connected via SMA-BNC conversion. | | style="text-align: center;" | Records PMT output, connected via SMA-BNC conversion. | ||
|- | |- | ||
| style="text-align: center;" | Caen DT5751 Digitiser | | style="text-align: center;" | Caen DT5751 Digitiser | ||
| style="text-align: center;" | Records PMT output, connected via SMA-MCX conversion. Used channel 3. | | style="text-align: center;" | Records PMT output, connected via SMA-MCX conversion. Used channel 3. | ||
|- | |- | ||
Line 59: | Line 59: | ||
| style="text-align: center;" | Sends 1 output from splitter to Oscilloscope. | | style="text-align: center;" | Sends 1 output from splitter to Oscilloscope. | ||
|- | |- | ||
| style="text-align: center;" | Male SMA to | | style="text-align: center;" | Male SMA to Male MCX cable | ||
| style="text-align: center;" | Sends 1 output from splitter to Digitiser | | style="text-align: center;" | Sends 1 output from splitter to Digitiser | ||
|- | |- |
Revision as of 10:22, 25 October 2018
Beam tests of the single module with PRaVDA Silicon strip tracker with trigger pulse output at the Birmingham Cyclotron with a 36 MeV beam.
Equipment List
Item | Notes |
---|---|
Single Module Scintillator Block | 3cm x 3cm x 5cm standard scintillator block. Optical gel required to couple Scintillator to PMT |
Photomultiplier Tube | Hamamatsu R13089 2" |
Portable Enclosure | Modified Peli 1510 Waterproof Wheeled Equipment Case. 230 x 555 x 350mm |
LeCroy HDO6104 Oscilloscope | Records PMT output, connected via SMA-BNC conversion. |
Caen DT5751 Digitiser | Records PMT output, connected via SMA-MCX conversion. Used channel 3. |
DAQ Laptop | Controls Caen HV supply; records data from Caen digitiser. |
Caen NDT1470 HV Supply | Supplies HV to PMT |
PRaVDA Strip Tracker | PRaVDA Unit A, 3x150um Si strip sensors with 90.4um strip pitch. Firmware version update to yield square pulse out when 2 or 3 layers have a strip over threshold per read out cycle |
Control Laptop x 3 | Two used for Remote Desktop control of LeCroy Oscilloscope and DAQ Laptop. Third used for taking down notes. |
Ethernet Switcher | Set in experiment room and connected LeCroy Oscilloscope and DAQ laptop. Output sent to control room Network Hub. |
Network Hub | Set in control room to take output from ethernet switcher. Control laptops connected via ethernet or 5GHz WiFi. |
Ethernet Cable x 3 | To connect 1 control laptop, the LeCroy HDO6104 and DAQ Laptop to their respective network hubs. |
Ethernet Cable | To connect control Network Hub to Ethernet Switcher. |
Male-to-Male SMA Cable | Signal from enclosure port to Splitter |
DC-4200 MHz Signal Splitter | Splits SMA signal to two SMA signals – sent to Oscilloscope and Digitiser. |
Male SMA to Male BNC cable | Sends 1 output from splitter to Oscilloscope. |
Male SMA to Male MCX cable | Sends 1 output from splitter to Digitiser |
USB Cable | Caen HV unit to DAQ Laptop |
Gloves | For handling scintillator |
Optical gel | For coupling scintillator to PMT |
Wipes | For removing optical gel |
Beam Tests
Calorimeter files currently located at /unix/pbt/users/dwalker/data/birm_21.02.18 on UCL HEP plus1 server.
PMT Current at HV supply -900 V, beam off: 150 μA
Run Number | High Voltage (V) | Scope Trigger (self trigger, negative edge, mV) | Target Beam Current / Rate | Collimator | Calorimeter Files | Tracker Files | Notes |
---|---|---|---|---|---|---|---|
00 | -900 | -100 | ~10 kHz | 2 mm | run00_2mmCol_160pA_trig100mV | -- | |
01 | -900 | -140 | 160 pA / ~10 kHz | 2 mm | run01_2mmCol_160pA_trig140mV | 2mmCol_160pA_30s_Run1 | Actual beam current rose to 240 pA then 270 pA |
02 | -900 | -70 | 260 pA | 2 mm | run02_2mmCol_260pA_trig70mV | 2mmCol_260pA_30s_Run2 | |
03 | -900 | -40 | 260 pA | 2 mm | run03_2mmCol_260pA_trig40mV | 2mmCol_260pA_30s_Run3 | Beam current ~160 pA |
04 | -900 | -140 | 1 nA | 2 mm | run04_2mmCol_1nA_trig140mV | 2mmCol_1nA_30s_Run4 | Beam current ~1.2 nA |
Test: HV reduced to -800 V, lights on, no increase in PMT current. Lights off for further beam runs. | |||||||
05 | -900 | -140 | 220 pA | 2 mm | run05_2mmCol_220pA_trig140mV_1mmPE | 2mmCol_220pA_30s_Run5 | 1 mm polyethylene cover on collimator
Beam current rose to ~260 pA |
06 | -900 | -140 | 160 pA | 2 mm | run06_2mmCol_160pA_trig140mV_1mmPE | 2mmCol_160pA_30s_Run6 | 1 mm polyethylene cover on collimator
Beam current rose to ~230 pA |
07 | -900 | -140 | 10 pA / ~30 kHz | 5 mm | run07_5mmCol_10pA_trig140mV | 5mmCol_10pA_30s_Run7 | No polyethylene
Beam current rose to ~30 pA |
08 | -900 | -140 | 10 pA | 5 mm | run08_5mmCol_10pA_trig140mV | 5mmCol_10pA_30s_Run8 | Repeat run for run 07 |
09 | -900 | -140 | 10 pA | 5 mm | run09_5mmCol_10pA_trig140mV_1mmPE | 5mmCol_10pA_30s_Run9 | 1 mm polyethylene cover on collimator
Beam spot moved - polyethylene cover slipped, 'cyclops' beam Beam current ~8 pA |
10 | -900 | -140 | 10 pA | 5 mm | run10_5mmCol_10pA_trig140mV_1mmPE | 5mmCol_10pA_30s_Run10 | Repeat run for run 09
Peak beam current 15 pA |
11 | -900 | -140 | 10 pA | 5 mm | run11_5mmCol_10pA_trig140mV_1mmPE_HalfCover | 5mmCol_10pA_30s_Run11 | 1 mm polyethylene half-cover on collimator
Beam current ~8 pA |