Proton Calorimetry/Experimental Runs/2018/Feb21: Difference between revisions
SimonJolly (talk | contribs) (Created page with "Beam tests of the single module with PRaVDA CMOS pixel sensors (PRIAPUS) at the Birmingham Cyclotron with a 36 MeV beam. == Equipment List ==") |
(→Equipment List: Added first-pass account of equipment) |
||
Line 2: | Line 2: | ||
== Equipment List == | == Equipment List == | ||
{| class="wikitable" | |||
! style="text-align: center;" | Item | |||
! style="text-align: center;" | Notes | |||
|- | |||
| style="text-align: center;" | Single Module Scintillator Block | |||
| style="text-align: center;" | Optical grease required to couple Scintillator to PMT | |||
|- | |||
| style="text-align: center;" | Photomultiplier Tube | |||
| style="text-align: center;" | (Hamamatsu 2"?) | |||
|- | |||
| style="text-align: center;" | Portable Enclosure | |||
| style="text-align: center;" | Modified Peli 1510 Waterproof Wheeled Equipment Case. | |||
230 x 555 x 350mm | |||
Features mount for scintillator and PMT, beam window and ports for SHV, BNC, and SMA cables. | |||
Requires a shield (paper? Mylar? tape?) to ensure the enclosure window is light-tight. | |||
|- | |||
| style="text-align: center;" | LeCroy HDO6104 Oscilloscope | |||
| style="text-align: center;" | Requires a power supply. | |||
|- | |||
| style="text-align: center;" | DAQ Laptop | |||
| style="text-align: center;" | Requires a power supply. (Connected to enclosure how? Or to LeCroy HDO6104? Requires USB?) | |||
|- | |||
| style="text-align: center;" | Control Laptop x 2 | |||
| style="text-align: center;" | One each for Remote Desktop control of LeCroy Oscilloscope and DAQ Laptop. Require power supplies. | |||
|- | |||
| style="text-align: center;" | Linksys EA6900 Network Hub x 2 | |||
| style="text-align: center;" | One for the experimental room for the LeCroy HDO6104 and DAQ Laptop to connect to, | |||
one for the control room for each of the Control Laptops to connect to. | |||
|- | |||
| style="text-align: center;" | Ethernet Cable (Long) | |||
| style="text-align: center;" | To connect the two Network Hubs and complete the network for controlling DAQ equipment from the control room. | |||
|- | |||
| style="text-align: center;" | BNC to SMA Cable (Short) | |||
| style="text-align: center;" | Signal from PMT to enclosure port | |||
|- | |||
| style="text-align: center;" | SMA to BNC Cable (Long) | |||
| style="text-align: center;" | Signal from enclosure port to LeCroy Oscilloscope | |||
|- | |||
| style="text-align: center;" | SHV Cable (Short) | |||
| style="text-align: center;" | HV supply from enclosure port to PMT | |||
|- | |||
| style="text-align: center;" | SHV Cable (Long) | |||
| style="text-align: center;" | HV supply from experimental room to enclosure port | |||
|} |
Revision as of 19:00, 16 February 2018
Beam tests of the single module with PRaVDA CMOS pixel sensors (PRIAPUS) at the Birmingham Cyclotron with a 36 MeV beam.
Equipment List
Item | Notes |
---|---|
Single Module Scintillator Block | Optical grease required to couple Scintillator to PMT |
Photomultiplier Tube | (Hamamatsu 2"?) |
Portable Enclosure | Modified Peli 1510 Waterproof Wheeled Equipment Case.
230 x 555 x 350mm Features mount for scintillator and PMT, beam window and ports for SHV, BNC, and SMA cables. Requires a shield (paper? Mylar? tape?) to ensure the enclosure window is light-tight. |
LeCroy HDO6104 Oscilloscope | Requires a power supply. |
DAQ Laptop | Requires a power supply. (Connected to enclosure how? Or to LeCroy HDO6104? Requires USB?) |
Control Laptop x 2 | One each for Remote Desktop control of LeCroy Oscilloscope and DAQ Laptop. Require power supplies. |
Linksys EA6900 Network Hub x 2 | One for the experimental room for the LeCroy HDO6104 and DAQ Laptop to connect to,
one for the control room for each of the Control Laptops to connect to. |
Ethernet Cable (Long) | To connect the two Network Hubs and complete the network for controlling DAQ equipment from the control room. |
BNC to SMA Cable (Short) | Signal from PMT to enclosure port |
SMA to BNC Cable (Long) | Signal from enclosure port to LeCroy Oscilloscope |
SHV Cable (Short) | HV supply from enclosure port to PMT |