** Noticed that particles were getting through a gap between the dosimetry box and the nozzle: due to Geant having difficulties with coinciding boundaries. | ** Noticed that particles were getting through a gap between the dosimetry box and the nozzle: due to Geant having difficulties with coinciding boundaries. |
Revision as of 14:47, 13 December 2017
Minutes for UCL Proton Calorimetry Meeting, 6th December 2017 (D17, Physics & Astronomy, UCL)
Present
Simon Jolly, Laurent Kelleter, Anastasia Basharina-Freshville, Jordan Silverman, Dan Walker
Matthieu Hentz:
- Refining Clatterbridge simulations:
- Noticed that particles were getting through a gap between the dosimetry box and the nozzle: due to Geant having difficulties with coinciding boundaries.
- Fixed by putting a brass ring around the nozzle on the outside of the box.
- Completing coursework and reading up on proton CT.
ABF:
- Fixed smearing of energy resolution in simulations:
- Was smearing pre and post simulations: post-simulation always used 8.5%; now only smearing pre-simulation with variable resolution.
- Now correlation between Monte Carlo truth and reconstructed energy spectrum.
- Still seeing low energy tail.
LK:
- PPRIG was good!
- Mike Merchant wants particle spectra for Geant4-DNA simulations.
- Very helpful comments during evening meal...
- Not sure whether initial proton retains 'primary proton' ID.
- Everything should be finished with paper:
- Waiting for Adam to write his parts and polish off.
- Clinical part needed from Richard Amos.
- No answer from Tracey Underwood: becoming less likely...
- Lots of code housekeeping!
- Will contact Michaela Esposito and Tony Price about ISDI sensors.
DW:
- Working on ROOT fitting for LeCroy binary data:
- Two classes for loading (LeCroyData) and analysing (LeCroySpectrum) data.
- Methods that get time/voltage arrays for individual triggers reset time to zero.
- Current integration in LeCroySpectrum chooses region based on voltage levels: SJ and LK suggested more robust to use time window. ABF said Caen integration window 100–200 ns.
- Will contact Tony Price at Birmingham regarding taking some data with trackers!
JS:
- Gone back to looking into CAD modelling in Geant4.
- Going through Matthieu's Clatterbridge simulations:
- Learning how simulations run.
- Investigating introducing sensitive detectors for particle measurements.