Proton Calorimetry/Experimental Runs/2014/Dec8-9: Difference between revisions
(Info dump: Word document notes from 08-09/12/2014 entered as tables with minimal formatting. Formatting and corrections to follow.) |
m (Formatting and minor corrections) |
||
Line 3: | Line 3: | ||
'''PAGE UNDER CONSTRUCTION''' | '''PAGE UNDER CONSTRUCTION''' | ||
__TOC__ | |||
=Day 1 (December 8th)= | |||
====Notes==== | |||
*Black cloth was placed around the box containing the module, but did NOT cover the face of the scintillator | |||
*Distance between the beam and the modeule: ~30 cm (as for previous tests) | |||
*Beam nozzle diameter: 34 mm | |||
===Rate Tests=== | |||
{|class="wikitable" | {|class="wikitable" | ||
!High Voltage (V) | !High Voltage (V) | ||
Line 16: | Line 24: | ||
| | | | ||
HV on: 10.30 am, data taking: 11.00 am | HV on: 10.30 am, data taking: 11.00 am | ||
*I: 65.8 μ | *I: 65.8 μA | ||
*Scope Threshold: 62 mV | *Scope Threshold: 62 mV | ||
*Rate: 430-500 Hz (after ~10 minutes of beam on) | *Rate: 430-500 Hz (after ~10 minutes of beam on) | ||
| | | | ||
*DC offset: 0 | *DC offset: 0 | ||
*Threshold | *Threshold 40 LSB | ||
*Gate offset: | *Gate offset: 20 ns | ||
*Charge sens.: 20 fC/LSB | *Charge sens.: 20 fC/LSB | ||
*Short gate: 60 ns | *Short gate: 60 ns | ||
Line 228: | Line 236: | ||
|} | |} | ||
=Day 2 (December 9th)= | |||
====Notes==== | |||
*HV on for 15 minutes before measurements started | |||
*Background rate for Hexagonal Module (for 800 V on the PMT, with beam off and 2 mm collimator in place): 4.5 Hz | |||
* Current at 800 V: 65.8 μA (with the beam off), 65.9 μA (with the beam on) | |||
===Rate Tests=== | |||
{|class="wikitable" | {|class="wikitable" | ||
!High Voltage (V) | !High Voltage (V) | ||
Line 280: | Line 289: | ||
| 2mm || 040 (350,000 events) | | 2mm || 040 (350,000 events) | ||
|- | |- | ||
| 900 || ST || As above + | | 900 || ST || || As above + | ||
*Long gate: 100 ns | *Long gate: 100 ns | ||
| 2 mm || 041 (350,000 events) | | 2 mm || 041 (350,000 events) | ||
Line 643: | Line 652: | ||
*Dose rate: 2 monitor units/minute | *Dose rate: 2 monitor units/minute | ||
| 082 (3,000,000 events) | | 082 (3,000,000 events) | ||
|- | |||
| 800 || ST | | 800 || ST | ||
| | | | ||
Line 688: | Line 698: | ||
*Arc current: 160 μA | *Arc current: 160 μA | ||
| 087 (300,000 events) | | 087 (300,000 events) | ||
|- | |||
| 1300 || ST | | 1300 || ST | ||
| | | | ||
Line 750: | Line 761: | ||
|} | |} | ||
==Beam Manipulation Tests== | |||
Beam Manipulation Tests | |||
*2 mm collimator in nozzle, 800 V | *2 mm collimator in nozzle, 800 V | ||
Latest revision as of 18:30, 24 July 2017
Include all details of experimental runs from Anastasia's PDFs.
PAGE UNDER CONSTRUCTION
Day 1 (December 8th)
Notes
- Black cloth was placed around the box containing the module, but did NOT cover the face of the scintillator
- Distance between the beam and the modeule: ~30 cm (as for previous tests)
- Beam nozzle diameter: 34 mm
Rate Tests
High Voltage (V) | Trigger | Rate + Additional Information | Electronics Setup | Collimator Size + Additional Information | Run Number |
---|---|---|---|---|---|
800 | ST |
HV on: 10.30 am, data taking: 11.00 am
|
|
|
002 (150,000 events) |
800 | ST |
|
As above | 3 mm | 003 (450,000 events) |
800 | ST |
|
As above | 5 mm | 004 (700,000 events) |
800 | ST |
|
As above | 4 mm | 005 (1,000,000 events) |
800 | ST |
|
As above | 8 mm | 006 (5,000,000 events) |
800 | ST |
|
As above | 10 mm | 007 (5,000,000 events) |
800 | ST |
|
As above | 10 mm (Repeat measurement - run 007) | 008 (4,600,000 events) |
800 | ST |
|
As above +
|
10 mm | 009 (3,000,000 events) |
800 | ST |
|
As above + Short gate: 49 ns, Long gate: 50 ns | 10 mm | 010 (2,500,000 events) |
800 | ST |
|
As above +
|
2 mm (Repeat measurement - run 002) | 011 (350,000 events) |
800 | ST | As above +
|
2 mm | 012 (350,000 events) | |
800 | ST |
|
As above | 2 mm (Repeat measurement - run 012) | 013 (350,000 events) |
800 | ST | As above +
|
2 mm | 014 (350,000 events) | |
800 | ST | As above +
|
2 mm (Repeat measurement - run 002) | 015 (350,000 events) | |
800 | ST |
|
As above | 1 mm | 016 (300,000 events) |
800 | ST |
|
As above | 0.5 mm, Cent red at 0 | 017 (320,000 events) |
800 | ST |
|
As above | 0.5 mm, 8 mm off centre, horizontal right | 018 (125,000 events) |
800 | ST |
|
As above | 0.5 mm, 16 mm off centre, horizontal right | 019 (100,000 events) |
800 | ST |
|
As above | 0.5 mm, 8 mm off centre, horizontal left | 020 (100,000 events) |
800 | ST |
|
As above | 0.5 mm, 16 mm off centre, horizontal left | 021 (100,000 events) |
800 | ST |
|
As avove | 0.5 mm, 8 mm off centre, vertical up | 022 (100,000 events) |
800 | ST |
|
As above | 0.5 mm, 8 mm off centre, vertical up | 023 (100,000 events) |
800 | ST |
|
As above | 2 mm (Repeat measurement - run 002) | 024 (350,000 events) |
800 | ST |
|
As above | 2 mm, Beam off (background run) | 025 (450 events) |
800 | ST |
|
As above | 2 mm, Flow rate: 1.3 cc/min | 026 (500,000 events) |
800 | ST |
|
As above | 2 mm, Flow rate: 1.6 cc/min | 027 (350,000 events) |
800 | ST |
|
As above | 2 mm | 028 (2,366,000 events) |
800 | ST |
|
As above | 2 mm, Flow rate: 1.1 cc/min, Arc current: 1/10th of therapy setting (0.8-0.9) | 029 (3,200,000 events) |
800 | ST |
|
As above | 2 mm, Arc current: ~1 turn away from "off" position | 030 (350,000 events) |
900 | ST | As above +
|
2 mm | 032 (350,000 events) | |
900 | ST | As above +
|
2 mm | 033 (350,000 events) | |
1000 | ST |
|
As above +
|
2 mm | 034 (350,000 events) |
1000 | ST | As above +
|
2 mm | 035 (350,000 events) | |
1000 | ST |
|
As above +
|
2 mm | 036 (350,000 events) |
Day 2 (December 9th)
Notes
- HV on for 15 minutes before measurements started
- Background rate for Hexagonal Module (for 800 V on the PMT, with beam off and 2 mm collimator in place): 4.5 Hz
- Current at 800 V: 65.8 μA (with the beam off), 65.9 μA (with the beam on)
Rate Tests
High Voltage (V) | Trigger | Rate + Additional Information | Electronics Setup | Collimator Size + Additional Information | Run Number |
---|---|---|---|---|---|
800 | ST |
|
As above +
|
|
037 (350,000 events) |
800 | ST | As above +
|
2 mm | 038 (350,000 events) | |
800 | ST |
|
As above +
|
2mm | 039 (350,000 events) |
900 | ST |
|
As above +
|
2mm | 040 (350,000 events) |
900 | ST | As above +
|
2 mm | 041 (350,000 events) | |
900 | ST |
|
As above +
|
2 mm | 042 (350,000 events) |
900 | ST |
|
As above +
|
2 mm
|
043 (350,000 events) |
900 | ST | As above +
|
2 mm
|
044 (350,000 events) | |
900 | ST | As above +
|
2 mm
|
045 (350,000 events) | |
800 | ST |
|
As above +
|
2 mm
|
046 (350,000 events) |
800 | ST | As above +
|
2mm
|
047 (350,000 events) | |
800 | ST |
|
As above +
|
2 mm
|
048 (350,000 events) |
800 | ST |
|
As above +
|
2 mm
|
049 (350,000 events) |
800 | ST | As above +
|
2mm
|
050 (350,000 events) | |
800 | ST | As above +
|
2 mm
|
051 (350,000 events) | |
900 | ST |
|
As above +
|
2mm
|
052 (350,000 events) |
900 | ST | As above +
|
2 mm
|
053 (350,000 events) | |
900 | ST | As above +
|
2mm
|
054 (350,000 events) | |
900 | ST |
|
As above | 2 mm
|
055 (350,000 events) |
900 | ST | As above +
|
2 mm
|
056 (350,000 events) | |
900 | ST | As above +
|
2 mm
|
057 (350,000 events) | |
800 | ST |
|
As above | 2 mm
|
058 (350,000 events) |
800 | ST | As above +
|
2 mm
|
059 (350,000 events) | |
800 | ST | As above +
|
2 mm
|
060 (350,000 events) | |
800 | ST |
|
As above +
|
2mm
|
061 (350,000 events) |
800 | ST | As above +
|
2 mm
|
062 (300,000 events) | |
800 | ST | As above +
|
2 mm
|
063 (300,000 events) | |
900 | ST |
|
As above +
|
2 mm
|
064 (143,000 events) |
900 | ST |
|
As above | 2mm
|
065 (315,000 events) |
900 | ST | As above +
|
2 mm
|
066 (300,000 events) | |
900 | ST | As above +
|
2 mm
|
067 (300,000 events) | |
900 | ST |
|
As above +
|
2 mm
|
068 (200,000 events) |
900 | ST | As above +
|
2 mm
|
069 (200,000 events) | |
800 | ST | As above +
|
2mm
|
070 (200,000 events) | |
800 | ST |
|
As above +
|
2 mm
|
071 (200,000 events) |
800 | ST | As above +
|
2 mm
|
072 (250,000 events) | |
800 | ST |
|
As above +
|
2 mm
|
073 (200,000 events) |
800 | ST |
|
As above +
|
2 mm
|
074 (200,000 events) |
800 | ST | As above +
|
2 mm
|
075 (200,000 events) | |
800 | ST | As above +
|
2 mm
|
076 (200,000 events) | |
900 | ST |
|
As above +
|
2 mm
|
077 (200,000 events) |
900 | ST | As above +
|
2mm
|
078 (120,000 events) | |
900 | ST | As above +
|
2mm
|
079 (100,000 events) | |
1100 | ST |
|
As above +
|
2 mm | 080 (200,000 events) |
1100 | ST | As above+
|
2 mm | 081 (200,000 events) | |
800 | ST |
|
As above +
|
2 mm
|
082 (3,000,000 events) |
800 | ST |
|
As above | 2 mm, As above +
|
083 (100,000 events) |
800 | ST |
|
As above | 2 mm, As above +
|
084 (3,250,000 events) |
800 | ST |
|
As above | 2 mm, As above +
|
085 (2,865,000 events) |
1300 | ST |
|
As above | 2 mm
|
086 (350,000 events) |
1300 | ST |
|
As above | 2 mm, As above +
|
087 (300,000 events) |
1300 | ST |
|
As above |
|
088 (100,000 events) |
1300 | ST |
|
As above | Beam stop:
|
089 (37,000 events) |
1300 | ST |
|
As above | Beam stop:
|
N/A |
1300 | ST |
|
As above | Beam stop:
|
N/A |
1300 | ST |
|
As above | Beam stop:
|
N/A |
Beam Manipulation Tests
- 2 mm collimator in nozzle, 800 V
Flow Rate, cc/minute | Arc Current | Dose Rate, monitor units/minute | Dephase, ° | Rate | PMT Current, μA |
---|---|---|---|---|---|
1.6 | 0 | 4-5 kHz | 69.95 | ||
1.6 | 70 μA | 1 | 250 kHz | ||
1.6 | Dropped compared to previous | 0.5 | 140 kHz | ||
1.6 | Increased compared to previous | 2 | 400 kHz | ||
1.6 | 115 μA | 2.2 | 400 kHz | ||
1.6 | 3.4 | 300 kHz | |||
1.6 | 150 μA | 2.1 | 400 kHz | ||
1.6 | 150 μA | 0.5 | 183 | 150 kHz | |
1.6 | 150 μA | 0.1 | 185 | 40 kHz | |
1.6 | 150 μA | 0 | 190 | 300 kHz | |
1.6 | 1 mA | 0 | 190 | 1 kHz | |
1.6 | 1 ma | 0.2 | 186 | 60 kHz | |
1.6 | 1 mA | 0.6 | 184.5 | 200 kHz |