Proton Calorimetry/Meetings/2017/03/29: Difference between revisions
SimonJolly (talk | contribs) (Created page with "== Minutes for UCL Proton Calorimetry Meeting, 29th March 2017 (D17, Physics & Astronomy, UCL) == === Present === '''Simon Jolly''', '''Laurent Kelleter''' '''LK''': * [http:/...") |
SimonJolly (talk | contribs) No edit summary |
||
(2 intermediate revisions by the same user not shown) | |||
Line 3: | Line 3: | ||
=== Present === | === Present === | ||
'''Simon Jolly''', '''Laurent Kelleter''' | '''Simon Jolly''', '''Laurent Kelleter''', '''Anastasia Basharina-Freshville''' | ||
'''ABF''': | |||
* Looking at specific peak PMT current: | |||
** Acquire data with different rates: | |||
** Calculate average current to compare at what point saturation occurs. | |||
** Matches predictions almost exactly! | |||
** Small rise at "saturation" current before drop off. | |||
* Will pass on information to Hamamatsu to "guide" them in producing lower gain PMTs. | |||
'''LK''': | '''LK''': | ||
* [http://www.hep.ucl.ac.uk/pbt/wikiData/presentations/2017/LK20170329_ProtonBuildUp.pdf Looking at dose build-up effect in proton therapy and secondary particles]. | * [http://www.hep.ucl.ac.uk/pbt/wikiData/presentations/2017/LK20170329_ProtonBuildUp.pdf Looking at dose build-up effect in proton therapy and secondary particles]. | ||
** | ** Secondary particles in Geant4 difficult to characterise due to range cut. | ||
** | ** <code>GetTotalEnergyDeposit()</code> doesn't include energy from secondary particles... | ||
* | ** Need to check whether 20 micron range cut is short enough with '''Adam Gibson'''. | ||
* | * Clear build-up effect from secondary protons: | ||
* | ** Need to check RBE of the resulting short-range protons. | ||
** Effect of hadronic build-up means Bragg curve incorrect for entrance dose. |
Latest revision as of 14:11, 29 March 2017
Minutes for UCL Proton Calorimetry Meeting, 29th March 2017 (D17, Physics & Astronomy, UCL)
Present
Simon Jolly, Laurent Kelleter, Anastasia Basharina-Freshville
ABF:
- Looking at specific peak PMT current:
- Acquire data with different rates:
- Calculate average current to compare at what point saturation occurs.
- Matches predictions almost exactly!
- Small rise at "saturation" current before drop off.
- Will pass on information to Hamamatsu to "guide" them in producing lower gain PMTs.
LK:
- Looking at dose build-up effect in proton therapy and secondary particles.
- Secondary particles in Geant4 difficult to characterise due to range cut.
GetTotalEnergyDeposit()
doesn't include energy from secondary particles...- Need to check whether 20 micron range cut is short enough with Adam Gibson.
- Clear build-up effect from secondary protons:
- Need to check RBE of the resulting short-range protons.