Proton Calorimetry/Meetings/2022/03/16: Difference between revisions
SaadShaikh (talk | contribs) |
SaadShaikh (talk | contribs) No edit summary |
||
(One intermediate revision by the same user not shown) | |||
Line 7: | Line 7: | ||
=== [[ELogs/SaadShaikh|Saad Shaikh]] === | === [[ELogs/SaadShaikh|Saad Shaikh]] === | ||
*Registered for IOP HEPP and APP conference and will give 15 min talk. | *Registered for IOP HEPP and APP conference and will give 15 min talk. | ||
**Will prepare presentation. | |||
*Simon to provide support letter for MAPS travel fund, to hopefully pay £800 towards CALOR 2022 conference. | *Simon to provide support letter for MAPS travel fund, to hopefully pay £800 towards CALOR 2022 conference. | ||
*25 10mm x 10mm x 3mm scintillator sheets drilled with fibre holes. | *25 10mm x 10mm x 3mm scintillator sheets drilled with fibre holes. | ||
Line 13: | Line 14: | ||
**Next step to implement scoring mesh to score dose sheet-by-sheet and Ntuple to count total photons by photodiode. | **Next step to implement scoring mesh to score dose sheet-by-sheet and Ntuple to count total photons by photodiode. | ||
*Xcode 13.3 and associated command line tools along with ROOT 6.26.00 appeared to have fixed compatibility problems. | *Xcode 13.3 and associated command line tools along with ROOT 6.26.00 appeared to have fixed compatibility problems. | ||
**Xcode 13.3 requires | **Xcode 13.3 requires macOS Monterey, so will test latest versions of Xcode, MacPorts, ROOT and Geant4 on DAQ laptop before upgrading main machine. |
Latest revision as of 12:07, 17 March 2022
Minutes for UCL Proton Calorimetry Meetings, 16th March
Present
Saad Shaikh, Raffaella Radogna
Saad Shaikh
- Registered for IOP HEPP and APP conference and will give 15 min talk.
- Will prepare presentation.
- Simon to provide support letter for MAPS travel fund, to hopefully pay £800 towards CALOR 2022 conference.
- 25 10mm x 10mm x 3mm scintillator sheets drilled with fibre holes.
- Will conduct lab tests when Simon 3D-prints new stack holder.
- Implemented Sensitive Detector for photodiodes and realistic beam characteristics using General Particle Source in Geant4 simulation.
- Next step to implement scoring mesh to score dose sheet-by-sheet and Ntuple to count total photons by photodiode.
- Xcode 13.3 and associated command line tools along with ROOT 6.26.00 appeared to have fixed compatibility problems.
- Xcode 13.3 requires macOS Monterey, so will test latest versions of Xcode, MacPorts, ROOT and Geant4 on DAQ laptop before upgrading main machine.