Proton Calorimetry/Meetings/2018/03/07: Difference between revisions
SimonJolly (talk | contribs) No edit summary |
SimonJolly (talk | contribs) No edit summary |
||
Line 10: | Line 10: | ||
** Should be able to match up events from scope with tracker events. | ** Should be able to match up events from scope with tracker events. | ||
** Now having to deal bugs in tracker reconstruction code... | ** Now having to deal bugs in tracker reconstruction code... | ||
* '''Tony Price''' confirms an energy of 28 +/-0.15 MeV. | * '''Tony Price''' confirms an energy of 28 +/- 0.15 MeV. | ||
* '''RS''' suggests broad energy spread may be a result of upstream tracker degrading the beam. | |||
* ''To Do'': | * ''To Do'': | ||
** Fix bugs in tracker reconstruction code. | ** Fix bugs in tracker reconstruction code. | ||
Line 17: | Line 18: | ||
'''JS''': | '''JS''': | ||
* | * CAD models of Clatterbridge beamline now complete based on '''MH''''s models: | ||
** Some material definitions not clear: Kapton needs clarifying. | |||
* '''MH''' suggests including the collimator and cap inside the nozzle. | |||
** | |||
* | |||
* ''To Do'': | * ''To Do'': | ||
** | ** Add collimator and cap. | ||
** Rerun simulations to check differences in simulations with CAD components. | ** Rerun simulations to check differences in simulations with CAD components. | ||
'''MH''': | |||
* Finished coursework: 7 weeks till next one. | |||
* Writing documentation for simulation: tidying up macros for publication. | |||
'''LK''': | '''LK''': | ||
* | * ISDI sensor now working with DAQ PC: | ||
** XCAP-Lite software runs under Windows 10. | |||
** Can see ambient light but not light from LEDs. | |||
* | |||
* | |||
** |
Latest revision as of 15:02, 7 March 2018
Minutes for UCL Proton Calorimetry Meeting, 7th March 2018 (D17, Physics & Astronomy, UCL)
Present
Simon Jolly, Dan Walker, Anastasia Basharina-Freshville, Matthieu Hentz, Jordan Silverman, Dan Walker, Laurent Kelleter
DW:
- Had discussions with Tony Price (+Mariana) at Birmingham:
- Marian has extracted timestamps for tracker data.
- Should be able to match up events from scope with tracker events.
- Now having to deal bugs in tracker reconstruction code...
- Tony Price confirms an energy of 28 +/- 0.15 MeV.
- RS suggests broad energy spread may be a result of upstream tracker degrading the beam.
- To Do:
- Fix bugs in tracker reconstruction code.
- Correlate with scintillator pulses.
- Create 3D dose distribution.
JS:
- CAD models of Clatterbridge beamline now complete based on MH's models:
- Some material definitions not clear: Kapton needs clarifying.
- MH suggests including the collimator and cap inside the nozzle.
- To Do:
- Add collimator and cap.
- Rerun simulations to check differences in simulations with CAD components.
MH:
- Finished coursework: 7 weeks till next one.
- Writing documentation for simulation: tidying up macros for publication.
LK:
- ISDI sensor now working with DAQ PC:
- XCAP-Lite software runs under Windows 10.
- Can see ambient light but not light from LEDs.