Proton Calorimetry/Meetings/2017/11/29: Difference between revisions
SimonJolly (talk | contribs) (Created page with "== Minutes for UCL Proton Calorimetry Meeting, 22nd November 2017 (D17, Physics & Astronomy, UCL) == === Present === '''Simon Jolly''', '''Laurent Kelleter''', '''Anastasia Bas...") |
SimonJolly (talk | contribs) No edit summary |
||
Line 3: | Line 3: | ||
=== Present === | === Present === | ||
'''Simon Jolly''', '''Laurent Kelleter''', '''Anastasia Basharina-Freshville''', '''Jordan Silverman''', '''Dan Walker''', '''Matthieu Hentz''' | '''Simon Jolly''', '''Ruben Saakyan''', '''Laurent Kelleter''', '''Anastasia Basharina-Freshville''', '''Jordan Silverman''', '''Dan Walker''', '''Matthieu Hentz''' | ||
'''ABF''': | '''ABF''': | ||
* | * Fitting finally seems to work for single module spectrum: | ||
** ''' | ** Landau-Gaussian convolution with second degree polynomial. | ||
** | ** ROOT requires specific order: fits Landau-Gaussian first. | ||
* | ** Small features on the left of peak show extra 'wrinkle' which is not quite fitted; not present in July'15 data with UCL negative base. | ||
** Contact person | ** Fit worse for MedAustron data but likely to be a result of pile-up. | ||
** | ** FWHM from fit overestimates resolution slightly. | ||
* Hamamatsu provided quote for flat panel detectors: | |||
** Contact person Simon Whitehead. | |||
** | ** Recommended C9730DK-10 with faster readout rate but larger noise. | ||
** Will | ** Will ask for quote for C9728SK-10 and check which has larger dynamic range. | ||
** Will also check whether we can get demo model to test: full cost £16k + £2k for software. | |||
''' | '''MH''': | ||
* | * Working on staged simulation to improve speed: | ||
** | ** Large speed difference between good and bad nodes: trying to script finding fastest nodes... | ||
** | ** Time limit of 12 hours for medium queue: some jobs overrun due to slow nodes and get ejected. | ||
* | * Also trying to visualise beam profile every 25mm: | ||
** Can't define overlapping geometries: need to include parallel world with sensitive detectors. | |||
** No response from Ben Morgan: will email Geant4 mailing list. | |||
** Sensitive detectors provide speed up over writing data in the stepping action. | |||
* Will look into getting Oyster cards for ENLIGHT meeting delegates. | |||
'''RS''': | |||
* Visit to Nuvia Monday/Tuesday: | |||
** Requested 100x100mm sheets, 2mm or 3mm thick depending on reliability of production. | |||
** Total thickness of 60mm | |||
** Nuvia produce a thick piece of scintillator, then squeeze under heat to correct thickness, then cut out sheet. | |||
** Previous issues result from lack of attention to pressing... | |||
** Samples will arrive before Christmas (perhaps not all...). | |||
** Hana about to go away on maternity leave... | |||
* Should be possible to cut and polish samples before they arrive: | |||
** Derek can cut some pieces from existing spares. | |||
** '''Georgio Savini''' and '''David Brooks''' should have expertise on polishing. | |||
** Nuvia may be able to polish themselves. | |||
'''DW''': | '''DW''': | ||
* | * ROOT scripts for reading Lecroy binary files is now working. | ||
* Will | ** Defines classes for acquiring and manipulating data. | ||
** Just got histogram spectrum working. | |||
''' | ** Will reject bad pulses and pulses with high variation in baseline. | ||
* | ** Can output data to suitable file format. | ||
** | |||
** | '''JS''': | ||
* | * Working on alternate fit for single module spectrum: | ||
* | ** Fit uses Landau-Gaussian convolution with extra exponential part. | ||
** Χ<sup>2</sup> per NDF above 5. | |||
* Not entirely dissimilar from Anastasia's fitting function... | |||
* Will review in a week. | |||
'''LK''': | '''LK''': | ||
* | * All of last few weeks spent writing paper on '''Build-Up Effects in Proton Therapy''': | ||
** | ** Struggling to define protonic build-up in robust way. | ||
** | ** Using 30% of Bragg peak good at high energy but poor at low energy. | ||
** | ** Bortfeld formula works in opposite direction: would rather not use fit (need to check with '''Adam Gibson'''). | ||
** | ** Have contacted '''Tracey Underwood''' to review paper. |
Latest revision as of 15:30, 29 November 2017
Minutes for UCL Proton Calorimetry Meeting, 22nd November 2017 (D17, Physics & Astronomy, UCL)
Present
Simon Jolly, Ruben Saakyan, Laurent Kelleter, Anastasia Basharina-Freshville, Jordan Silverman, Dan Walker, Matthieu Hentz
ABF:
- Fitting finally seems to work for single module spectrum:
- Landau-Gaussian convolution with second degree polynomial.
- ROOT requires specific order: fits Landau-Gaussian first.
- Small features on the left of peak show extra 'wrinkle' which is not quite fitted; not present in July'15 data with UCL negative base.
- Fit worse for MedAustron data but likely to be a result of pile-up.
- FWHM from fit overestimates resolution slightly.
- Hamamatsu provided quote for flat panel detectors:
- Contact person Simon Whitehead.
- Recommended C9730DK-10 with faster readout rate but larger noise.
- Will ask for quote for C9728SK-10 and check which has larger dynamic range.
- Will also check whether we can get demo model to test: full cost £16k + £2k for software.
MH:
- Working on staged simulation to improve speed:
- Large speed difference between good and bad nodes: trying to script finding fastest nodes...
- Time limit of 12 hours for medium queue: some jobs overrun due to slow nodes and get ejected.
- Also trying to visualise beam profile every 25mm:
- Can't define overlapping geometries: need to include parallel world with sensitive detectors.
- No response from Ben Morgan: will email Geant4 mailing list.
- Sensitive detectors provide speed up over writing data in the stepping action.
- Will look into getting Oyster cards for ENLIGHT meeting delegates.
RS:
- Visit to Nuvia Monday/Tuesday:
- Requested 100x100mm sheets, 2mm or 3mm thick depending on reliability of production.
- Total thickness of 60mm
- Nuvia produce a thick piece of scintillator, then squeeze under heat to correct thickness, then cut out sheet.
- Previous issues result from lack of attention to pressing...
- Samples will arrive before Christmas (perhaps not all...).
- Hana about to go away on maternity leave...
- Should be possible to cut and polish samples before they arrive:
- Derek can cut some pieces from existing spares.
- Georgio Savini and David Brooks should have expertise on polishing.
- Nuvia may be able to polish themselves.
DW:
- ROOT scripts for reading Lecroy binary files is now working.
- Defines classes for acquiring and manipulating data.
- Just got histogram spectrum working.
- Will reject bad pulses and pulses with high variation in baseline.
- Can output data to suitable file format.
JS:
- Working on alternate fit for single module spectrum:
- Fit uses Landau-Gaussian convolution with extra exponential part.
- Χ2 per NDF above 5.
- Not entirely dissimilar from Anastasia's fitting function...
- Will review in a week.
LK:
- All of last few weeks spent writing paper on Build-Up Effects in Proton Therapy:
- Struggling to define protonic build-up in robust way.
- Using 30% of Bragg peak good at high energy but poor at low energy.
- Bortfeld formula works in opposite direction: would rather not use fit (need to check with Adam Gibson).
- Have contacted Tracey Underwood to review paper.