Proton Calorimetry/Meetings/2022/05/11: Difference between revisions

From PBTWiki
Jump to navigation Jump to search
(Created page with "== Minutes for UCL Proton Calorimetry Meetings, 11th May == === Present === '''Saad Shaikh''', '''Simon Jolly''', '''Raffaella Radogna''' === Saad Shaikh ...")
 
No edit summary
 
(2 intermediate revisions by the same user not shown)
Line 6: Line 6:


=== [[ELogs/SaadShaikh|Saad Shaikh]] ===
=== [[ELogs/SaadShaikh|Saad Shaikh]] ===
*Completed LED lab tests with unpainted sheets and white paper, black card and mylar foil. Results presented in this presentation.
*Completed [https://www.hep.ucl.ac.uk/pbt/wiki/Proton_Calorimetry/Experimental_Runs/2022/MayLED LED lab tests] with unpainted sheets and white paper, black card and mylar foil. Results presented in [http://www.hep.ucl.ac.uk/pbt/wikiData/presentations/2022/SS220511_LED.pptx this presentation].
**Mylar foil provides best combination of large signal and minimum cross-talk.
**Mylar foil provides best combination of large signal and minimum cross-talk.
**Still observe around 5% crosstalk, due to light leaking around edges of sheet.
**Still observe around 5% crosstalk, due to light leaking around edges of sheet.
Line 12: Line 12:
**White painted sheets 10-20 times dimmer than unpainted sheets – optical gel may not be necessary at all.
**White painted sheets 10-20 times dimmer than unpainted sheets – optical gel may not be necessary at all.
**Should perform test again with black stack holder before and after spray-painting black.
**Should perform test again with black stack holder before and after spray-painting black.
*Nexys Video board died during LED tests with Rev. C boards. Unclear cause of issue and Rev. C boards now give incorrect configuration pattern when using new Nexys Video board.
**Asked Matt Warren to look at Nexys Video board and will investigate Rev. C issues further.
*Spoke with Ruben about measuring Birks constant. Tests possible with proton beam at UCLH and with alpha particles and electrons at UCL.
*Spoke with Ruben about measuring Birks constant. Tests possible with proton beam at UCLH and with alpha particles and electrons at UCL.
**Need to discuss further – but work could make for a good MSci project.
**Need to discuss further – but work could make for a good MSci project.
*Will prepare talks/posters for CALOR and Elba conference.
*Will prepare talks/posters for CALOR and Elba conference.

Latest revision as of 11:22, 16 May 2022

Minutes for UCL Proton Calorimetry Meetings, 11th May

Present

Saad Shaikh, Simon Jolly, Raffaella Radogna

Saad Shaikh

  • Completed LED lab tests with unpainted sheets and white paper, black card and mylar foil. Results presented in this presentation.
    • Mylar foil provides best combination of large signal and minimum cross-talk.
    • Still observe around 5% crosstalk, due to light leaking around edges of sheet.
    • Optical gel increases signal level by 20-30% without increasing cross-talk.
    • White painted sheets 10-20 times dimmer than unpainted sheets – optical gel may not be necessary at all.
    • Should perform test again with black stack holder before and after spray-painting black.
  • Nexys Video board died during LED tests with Rev. C boards. Unclear cause of issue and Rev. C boards now give incorrect configuration pattern when using new Nexys Video board.
    • Asked Matt Warren to look at Nexys Video board and will investigate Rev. C issues further.
  • Spoke with Ruben about measuring Birks constant. Tests possible with proton beam at UCLH and with alpha particles and electrons at UCL.
    • Need to discuss further – but work could make for a good MSci project.
  • Will prepare talks/posters for CALOR and Elba conference.