==Photodiode Live Fit== | ==Photodiode Live Fit== | ||
*See below for details on the fitting procedure. The script <code>liveFit.cpp</code> can be used to fit photodiode data as it is being acquired. | *See below for details on the fitting procedure. The script <code>liveFit.cpp</code> can be used to fit photodiode data as it is being acquired. | ||
*In addition to background and shoot-through measurements, a configuration file "sheetConfig.txt" should be placed in the data-folder containing the lines: | |||
**Physical stack thickness in mm | |||
**Comma-separated values listing the sheet order | |||
**Stack WET (leave as 0 if not known) | |||
*To compile the script: <code>g++ -o liveFit liveFit.cpp `root-config --cflags --glibs`</code> | *To compile the script: <code>g++ -o liveFit liveFit.cpp `root-config --cflags --glibs`</code> | ||
*To execute the script: <code>./liveFit 2 12.5 folder background.txt backST.txt frontST.txt true</code> | *To execute the script: <code>./liveFit 2 12.5 folder background.txt backST.txt frontST.txt true</code> | ||
Line 49: | Line 53: | ||
*This script "replays" a previously acquired measurement, as if it were being captured at that moment. | *This script "replays" a previously acquired measurement, as if it were being captured at that moment. | ||
*To compile the script: <code>g++ -o replay replay.cpp `root-config --cflags --glibs`</code> | *To compile the script: <code>g++ -o replay replay.cpp `root-config --cflags --glibs`</code> | ||
*To execute the script: ./replay 2 350 0 170 50 capture.txt step/avg 50 100 (clean folder background.txt backST.txt frontST.txt) | *To execute the script: <code>./replay 2 350 0 170 50 capture.txt step/avg 50 100 (clean folder background.txt backST.txt frontST.txt)</code> | ||
**The first argument is the number of DDC232 boards. | **The first argument is the number of DDC232 boards. | ||
**The second argument is the DDC232 FSR. | **The second argument is the DDC232 FSR. | ||
Line 64: | Line 68: | ||
==Fitting QuARC Data== | ==Fitting QuARC Data== | ||
*To fit previously acquired photodiode data, the scripts <code>calibrate.cpp</code> and <code>fit.cpp</code> are used. | *To fit previously acquired photodiode data, the scripts <code>calibrate.cpp</code> and <code>fit.cpp</code> are used. | ||
*In addition to the photodiode data, a configuration file "sheetConfig.txt" should be placed in the data-folder containing the lines: | |||
**Physical stack thickness in mm | |||
**Comma-separated values listing the sheet order | |||
**Stack WET (leave as 0 if not known) | |||
*To compile the calibration script: <code>g++ -o calibrate calibrate.cpp `root-config --cflags --glibs`</code> | *To compile the calibration script: <code>g++ -o calibrate calibrate.cpp `root-config --cflags --glibs`</code> | ||
*To execute the calibration script: <code>./calibrate 2 12.5 folder background.txt frontST.txt backST.txt data.txt</code> | *To execute the calibration script: <code>./calibrate 2 12.5 folder background.txt frontST.txt backST.txt data.txt</code> | ||
Line 72: | Line 80: | ||
*The output of this script is a file containing two lines: calibrated average photodiode values and standard deviations. | *The output of this script is a file containing two lines: calibrated average photodiode values and standard deviations. | ||
*To compile the fitting script: <code>g++ -o fit fit.cpp `root-config --cflags --glibs`</code> | *To compile the fitting script: <code>g++ -o fit fit.cpp `root-config --cflags --glibs`</code> | ||
*To execute the fitting script: <code>./fit 2 | *To execute the fitting script: <code>./fit 2 folder data.txt energy facility</code> | ||
**The first argument is the number of DDC232 boards. | **The first argument is the number of DDC232 boards. | ||
**The second | **The second argument is the folder containing the measurements. | ||
**The third argument is the name of the calibrated data (which should reside in a directory called "calibrated" in "folder"). | |||
**The | **The fourth argument is the facility beam energy in MeV (MeV/u for HIT), which is used as a label for the plot and to load the reference curve. | ||
**The | **The fifth argument is the facility, used to load the reference curve. Choose either "UCLH" or "HIT". | ||
*The calibration and fitting scripts can be executed consecutively using the bash script <code>fit.sh</code>. | *The calibration and fitting scripts can be executed consecutively using the bash script <code>fit.sh</code>. | ||
Latest revision as of 16:46, 12 May 2021
This page contains information on the analysis code for the QuARC detector data.
Photodiode Data Processing
Details on how to acquire data from the DDC232 can be found here.
- Data is saved in hexadecimal format where one line represents data of all photodiodes in the setup. Each DDC232 channel measurement is represented by 5 hexadecimal characters.
- In any script analysing DDC232 data, each 5-character hex value is converted to an absolute decimal and then converted to a charge in pC. The zero-current offset is subtracted in the same step.
- The photodiode-input-resistor maps ensure that the ordering of measurements represents the physical order of photodiodes/accounts for input summing.
- As each photodiode is split across two inputs (as of rev. B), the 32 total measurements become 16 measurements, where inputs of the same photodiode are summed.
- Practically, this makes the full-scale range twice that of what is set on the FPGA.
Photodiode Live Plot
- The script
livePlot.cpp
can be used to plot photodiode data live while being acquired byFTDI.cpp
. - To compile the script:
g++ -o livePlot livePlot.cpp `root-config --cflags --glibs`
- To execute the script:
./livePlot 1 350 0 (clean folder background.txt backST.txt frontST.txt)
- The first argument is the number of DDC232 boards.
- The second argument is the DDC232 FSR.
- The third argument is a custom y-scale range (set to 0 for default).
- The fourth argument "clean" is an optional argument to plot data with background subtraction and calibration corrections.
- The fifth argument is the folder containing the background and calibration measurements. The remaining arguments are the filenames.
- If the "clean" option is used, the output file
output.csv
will be updated with a single line containing the background subtracted, calibrated data.
Photodiode Live Fit
- See below for details on the fitting procedure. The script
liveFit.cpp
can be used to fit photodiode data as it is being acquired. - In addition to background and shoot-through measurements, a configuration file "sheetConfig.txt" should be placed in the data-folder containing the lines:
- Physical stack thickness in mm
- Comma-separated values listing the sheet order
- Stack WET (leave as 0 if not known)
- To compile the script:
g++ -o liveFit liveFit.cpp `root-config --cflags --glibs`
- To execute the script:
./liveFit 2 12.5 folder background.txt backST.txt frontST.txt true
- The first argument is the number of DDC232 boards.
- The second argument is the DDC232 FSR.
- The third argument is a custom y-scale range (set to 0 for default).
- The fourth argument is an optional argument to plot data with background subtraction and calibration corrections.
- The fifth argument is the folder containing the background and calibration measurements. The next three arguments are the filenames.
- The final argument is to choose to display the ROOT plot with the fit results or not.
- The output file
output.csv
will be updated with a line containing the the background subtracted, calibrated data and another line containing y-values of the fitted function. This can be used in the web-based GUI.
- The script
prog.sh
can be used to easily executeFTDI.cpp
at the same time as eitherlivePlot.cpp
orliveFit.cpp
.
Photodiode Noise Analysis
- The script
analysis.cpp
analyses DDC232 data to report the amount of external electronic noise present in the data. This is useful in determining the quality of the data. - To compile the script:
g++ -o analysis analysis.cpp `root-config --cflags --glibs`
- To execute the script:
./analysis 4 folder capture.txt
- The first argument is the number of DDC232 boards.
- The second argument is the folder containing the captured data.
- The third argument is the name of the data file.
- The script produces the following plots both by individual DDC232 channel and by photodiode (if summing is present):
- Average value with standard deviation
- Histogram
- Time evolution graph (measured value against sample number)
Photodiode Replay
- This script "replays" a previously acquired measurement, as if it were being captured at that moment.
- To compile the script:
g++ -o replay replay.cpp `root-config --cflags --glibs`
- To execute the script:
./replay 2 350 0 170 50 capture.txt step/avg 50 100 (clean folder background.txt backST.txt frontST.txt)
- The first argument is the number of DDC232 boards.
- The second argument is the DDC232 FSR.
- The third argument is a custom y-axis range (set to 0 for default).
- The fourth argument is the DDC232 integration time.
- The fifth argument is the target frame rate of the ROOT plot.
- The sixth argument is the full path and name of the captured data.
- The seventh argument is the mode: "step" or "avg".
- Step replays each individual measurement at approximately the target frame rate. In this mode, the eighth and ninth arguments are the meausrement number to start and finish on respectively.
- Avg replays an average of measurements along with a standard deviation. The number of measurements averaged in each frame is given by the eigth argument*1000 divided by the integration time. It represents the avergaing rate in Hz. The ninth argument is ignored in this mode.
- The tenth argument "clean" is optional and can be used to replay photodiode data with previously measured background and calibration corrections.
- The eleventh, argument is the folder the background and front and back shoot-through measurements are in. The remaining arguments are the filenames.
Fitting QuARC Data
- To fit previously acquired photodiode data, the scripts
calibrate.cpp
andfit.cpp
are used. - In addition to the photodiode data, a configuration file "sheetConfig.txt" should be placed in the data-folder containing the lines:
- Physical stack thickness in mm
- Comma-separated values listing the sheet order
- Stack WET (leave as 0 if not known)
- To compile the calibration script:
g++ -o calibrate calibrate.cpp `root-config --cflags --glibs`
- To execute the calibration script:
./calibrate 2 12.5 folder background.txt frontST.txt backST.txt data.txt
- The first argument is the number of DDC232 boards.
- The second argument is the DDC232 FSR.
- The third argument is the folder containing the measurements.
- The fourth, fifth, sixth and seventh argument are the filenames for the background, front and back shoot-through and proton beam measurements.
- The output of this script is a file containing two lines: calibrated average photodiode values and standard deviations.
- To compile the fitting script:
g++ -o fit fit.cpp `root-config --cflags --glibs`
- To execute the fitting script:
./fit 2 folder data.txt energy facility
- The first argument is the number of DDC232 boards.
- The second argument is the folder containing the measurements.
- The third argument is the name of the calibrated data (which should reside in a directory called "calibrated" in "folder").
- The fourth argument is the facility beam energy in MeV (MeV/u for HIT), which is used as a label for the plot and to load the reference curve.
- The fifth argument is the facility, used to load the reference curve. Choose either "UCLH" or "HIT".
- The calibration and fitting scripts can be executed consecutively using the bash script
fit.sh
.
Useful literature
- Laurent's paper on the quenched Bragg model.
- Original paper introducing Birks' Law.
- Paper mentioning 2nd order extension to Birks' Law.
- Paper on Bortfeld's analytical approximation of the Bragg curve.
- Paper on reference FLUKA curves at HIT.
- Paper on creating SOBPs.
- Paper about LibdEdx and its follow-up.
- Paper on Kramer's model.
Notes on Fitting
- Sigma is estimated with Bortfeld's approximation, which is only truly valid for protons.
- While sigma can be estimated from a Gaussian fit of the Bragg peak, the poor spatial resolution of the detector means that Bortfeld's estimation tends to work better for all particle species.
- Phi0 is estimated with a rough guess using the largest count.
- For low energies, there are more direct proton hits in the sensor, so the fit start is moved to avoid the first few sheets.
- The fit end is chosen to avoid the fragmentation tails of ion fits.
- Birks' law to second order has been implemented, though currently not tested. C is set to 0. kB is set to a rough estimate of 0.07, typically correct for protons.
- The particle species, material and buildup approximation codes are used as fake fixed parameters in the model, to set the correct constants.
- The buildup approximation is rarely ever used and can be ignored.
- The QB model is implemented in a TF1 object and is fitted using ROOT's binned fitting routine.
- After the QB model is fitted, the relevant fit parameter results are extracted to recover Bortfeld's Bragg curve, which can be compared against facility reference curves.
- The
quenchedBraggHist
function implements ROOT's binned fit by hand, it is often slower but can be useful for measurements with only a small number of data points.
- The
SOBP Fit
- A reference SOBP for HIT can be constructed by interpolating and weighting individual FLUKA curves using the number of proton beams delivered, their energies and the number of particles in each beam.
- An SOBP fit just weighs and sums individual proton beams, using the additional parameters chi and p, which are described in the literature linked above.
- Chi and p are estimated by hand.
Ion Fits
- As mentioned, for ion fits, the QB fit range must be restricted to avoid the nuclear fragmentation tail after the Bragg peak.
- The QB model performs reasonably well with helium, but may not describe carbon well.
- Reference FLUKA curves for HIT are currently being sought in order to accurately determine the QB model performance in ion fits.
- Birks' law to second-order may be necessary here.
Future Development
- Replace the QB model with Kramer's numerical model for depth-dose curves, applicable to all ions, and then apply (second-order) Birks' law.
- Fitting routine using GNU Scientific Library rather than ROOT for potentially faster curve fitting.
CMOS Sensor Image Analysis (Legacy)
Details on how to process images taken by the ISDI CMOS Sensor to recover the average light output in each scintillator sheet.
- First, the 21 images taken by the CMOS sensor must be corrected for non-linearity effects in the photon-electron conversion. The MATLAB script
linear_corr_tiff.m
does this.- The correct full-well mode must be selected in the script, typically high full-well is chosen for its superior linearity.
- The script loops over each pixel in the 21 images and applies a correction using cubic interpolation of the linearity data (linearity_high.txt). A corrected version of each image is saved.
- The 21 corrected images are then averaged using
averageTiffs.sh
, which outputs a single image.- On MacOS, this may require ImageMagick, which can be installed with MacPorts:
sudo port install ImageMagick
- On MacOS, this may require ImageMagick, which can be installed with MacPorts:
- To apply background subtraction and corrections for non-linearity in scintillator light output, the MATLAB script
edit_runs.m
is run.- This requires a corrected/averaged background and shoot-through measurements (front and/or back).
- Important for background and shoot-through to have the same full-well mode as the measurement. Similar spot size for the shoot-through and measurement is also desirable.
- The script outputs a .txt file containing a column of data, representing the light output in each horizontal pixel row in arbitrary units.
- As part of the fitting procedure, the method
readCMOSData
calibrates the x-axis to WET and calculates the average light output in each sheet:- Each scintillator sheet is enumerated and a vector of the sheet thickness (in numerical order) is hardcoded along with the configuration of the sheets for a given experimental run.
- A small thickness correction is applied based on the physical measured thickness of the stack and the perceived thickness of the stack in the sensor.
- The sheet edges in WET is found by multiplying the corrected thickness by the RSP, which is found from the ratio of the measured WET of the stack and the physical thickness.
- The light output in each sheet (0.5 millimetres away from the edges) is averaged and then normalised based either on the maximum measured light output or the reference curve at detector entry.
- Uncertainty is calculated with contributions from: sheet cross-talk, direct hits of protons in the sensor, averaging errors, spot size and position and background.