Proton Calorimetry/Meetings/2020/02/17: Difference between revisions

From PBTWiki
Jump to navigation Jump to search
No edit summary
 
(One intermediate revision by the same user not shown)
Line 7: Line 7:
=== [[ELogs/SaadShaikh|Saad Shaikh]] ===
=== [[ELogs/SaadShaikh|Saad Shaikh]] ===
* he is able to fit real data using Laurent's code
* he is able to fit real data using Laurent's code
** all of the steps are included, quenched bragg fit and reconstructed curve. comparison with simulated distrivution is also included.
** all of the steps are included, quenched bragg fit and reconstructed curve. comparison with simulated distribution is also included.
* the range is always slightly underestimated
* the range is always slightly underestimated
** fitting simulated data, a small underestimation comes from the model
** fitting simulated data, a small underestimation comes from the model
** fitting real data, the underestimation is consistent with uncertainties
** fitting real data, the underestimation is consistent with uncertainties
* he tried data for measuring range withour PMMA absorbers and data with absorbers to double check the WE thickness of the absorber
* he tried data for measuring range without PMMA absorbers and data with absorbers to double check the WE thickness of the absorber
* the analysis includes Bkg subtraction and calibration
* the analysis includes Bkg subtraction and calibration
* comparison of run 47 30mm vs 52 21 mm and dependence with beam size
* comparison of run 47 30mm vs 52 21 mm and dependence with beam size
Line 22: Line 22:
* has been busy with grant application
* has been busy with grant application
* performed hardware test to optimise the design of the electronic board with Bernard.
* performed hardware test to optimise the design of the electronic board with Bernard.
** the best option is having 2.86 mm pitch for best coupling PDs array and scintillator sheets
** the best option is having 2.86 mm pitch for best coupling PDs array and scintillator sheets [http://www.hep.ucl.ac.uk/pbt/wikiData/presentations/2020/RR17022020_CircuitBoard_optimization.pptx presentation]
* will double check with knowledge exchange the information provided by Laura about the market research grant
* will double check with knowledge exchange the information provided by Laura about the market research grant
* will update CosyLab and provide a draft
* will update CosyLab and provide a draft

Latest revision as of 17:12, 15 April 2020

Minutes for UCL Proton Calorimetry Meetings, 17th February (D17, Physics & Astronomy, UCL)

Present

Simon Jolly, Laurent Kelleter, Saad Shaikh, Raffaella radogna

Saad Shaikh

  • he is able to fit real data using Laurent's code
    • all of the steps are included, quenched bragg fit and reconstructed curve. comparison with simulated distribution is also included.
  • the range is always slightly underestimated
    • fitting simulated data, a small underestimation comes from the model
    • fitting real data, the underestimation is consistent with uncertainties
  • he tried data for measuring range without PMMA absorbers and data with absorbers to double check the WE thickness of the absorber
  • the analysis includes Bkg subtraction and calibration
  • comparison of run 47 30mm vs 52 21 mm and dependence with beam size
    • the smaller beam has higher light output, but the difference in light output compensates at the Bragg peak.
    • will plot spot size intermediate steps to check the consistency of the measurements.
  • started implementing more object oriented way of implementing data.
  • he is interested in running geant4 simulations in the near future

Raffaella Radogna

  • has been busy with grant application
  • performed hardware test to optimise the design of the electronic board with Bernard.
    • the best option is having 2.86 mm pitch for best coupling PDs array and scintillator sheets presentation
  • will double check with knowledge exchange the information provided by Laura about the market research grant
  • will update CosyLab and provide a draft

Laurent Kelleter

  • cross talk measurements performed last week
    • LED with optical fibers to inject light
    • he will perform the analysis to quantify it.
  • final version of the quenched bragg paper for submission
  • will start sending his thesis to Simon for corrections