Proton Calorimetry/Meetings/2019/11/12: Difference between revisions

From PBTWiki
Jump to navigation Jump to search
No edit summary
No edit summary
 
(3 intermediate revisions by the same user not shown)
Line 14: Line 14:
* new directory [http://www.hep.ucl.ac.uk/pbt/wikiData/teaching/ pbt/wikiData/teaching]
* new directory [http://www.hep.ucl.ac.uk/pbt/wikiData/teaching/ pbt/wikiData/teaching]


=== [[ELogs/SimonJolly|Simon Jolly]] ===
=== [[ELogs/LaurentKelleter|Laurent Kelleter]] ===
*  
* presents results about range uncertainties of the QuARC [http://www.hep.ucl.ac.uk/pbt/wikiData/presentations/2019/LK20191107_RangeUncertainties.odp slides]
** uncertainty from the fit of light-depth curve is about 50um, but there are other uncertainties discussed in his presentation
* all the systematics discussed will be included in the QuARC paper and the thesis
* the paper about mixed beam has been reviewed with positive outcome. Lenny and Laurent will answer.


=== [[ELogs/RaffaellaRadogna|Raffaella Radogna]] ===
=== [[ELogs/RaffaellaRadogna|Raffaella Radogna]] ===
*  
* worked on setup. New way of coupling PD to the scintillator stack
* run an experiment injecting light to a sheet at the time to check the cross talk
* will analyse data


 
=== [[ELogs/SimonJolly|Simon Jolly]] ===
=== [[ELogs/LaurentKelleter|Laurent Kelleter]] ===
* meeting with Cham on Friday this week
*

Latest revision as of 17:51, 12 November 2019

Minutes for UCL Proton Calorimetry Meetings, 12th November 2019 (D17, Physics & Astronomy, UCL)

Present

Simon Jolly, Laurent Kelleter, Raffaella Radogna, Saad Shaikh

Saad Shaikh

  • progress on fitting Bortfeld's Bragg curve on simulation data from Geant4 (from Laurent)
  • the code is ported in Eclipse and now is cpp executable, but still uses ROOT
  • next step will be the quenched Bragg curve and real data analysis
  • he will also start running the CMOS sensor and collect instructions about
    • running the software and acquiring images
    • analysing images
  • new directory pbt/wikiData/teaching

Laurent Kelleter

  • presents results about range uncertainties of the QuARC slides
    • uncertainty from the fit of light-depth curve is about 50um, but there are other uncertainties discussed in his presentation
  • all the systematics discussed will be included in the QuARC paper and the thesis
  • the paper about mixed beam has been reviewed with positive outcome. Lenny and Laurent will answer.

Raffaella Radogna

  • worked on setup. New way of coupling PD to the scintillator stack
  • run an experiment injecting light to a sheet at the time to check the cross talk
  • will analyse data

Simon Jolly

  • meeting with Cham on Friday this week